/8 3/4x5/8 1/2x3/8 3/4x5/8 Recirculating fluid (Note 6,7,8) Pure water, Hydrofluoric acid, Ammonia hydrogen peroxide solution etc.
Metric size Inch size ASD 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 23 04 06 08 10 12 3.2 4 6 8 10 12 With One-touch fittings AS Stainless steel specifications (Stainless steel 303) AS-FE KE AS-FG AS-FG Use 1/8" tube. Made to Order AS-FP AS-FM Grease-free (Seal: Fluorine Coated) + Throttle Valve (Without Check Valve) X21 Lubricant: Vaseline X12 AS-D AS-T Ex.)
/Z80 D-C73C/C80C RS H A 8 10 9 10 10 11 D-C7 D-C80 10 15 50 50 + 45 (n2) D-B5/B64 8 10 13 4 8.5 9 14 4.5 9 10 14 5 10 10 14 6 9.5 11 17 6.5 10.5 11 16 6.5 10.5 11 18 7 11 9 10 9 10 10 11 11 11 9 10 10 11 RZQ 15 + 45 ( ) n2 2 D-H7 D-H7W D-H7BAL D-H7NF D-B59W 13 (n = 2, 4, 6, ) D-H7/H7NF/H7W/H7BAL 4 10 15 60 60 + 45 (n2) MI W S D-H7C 7 D-A3/A44 D-G39/K39 8 CEP1 D-C73C D-C80C D-H7C 10 15 65
D side D B M C8 8 One-touch fitting 2 to 16 stations FU1 Fuji Electric Co., Ltd.
1 2 3 Stations D side U side Blocking indication label 3 m D side U side D-sub connector cable AXT100 DS25030 C8: One-touch fitting for 8 VVQ2000-R-4-C8 Built-in silencer, direct exhaust [-S] Port plug VVQ1000-58A Individual EXH spacer Individual EXH spacer port size CB (SUP) port One-touch fitting for 8 F kit (D-sub connector) Manifold base (8 stations) VV5Q2408FU2D D side U side EXH outlet
ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM
ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM
ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM
TMH Electroless nickel plated ASD Easy to use AS Larger knob Push-lock type AS-FE Easy to lock KE Body size D [mm] 1 9.4 Unlock Lock AS-FG D 2 12 (Port size 1/8) AS-FP 13 (Port size 1/4) 3 16.6 AS-FM 4 18.8 AS-D AS-T ASP ASN AQ ASV Improved tube insertion/removal AK Max.
ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM
ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM
Metric size Inch size ASD 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 23 04 06 08 10 12 3.2 4 6 8 10 12 With One-touch fittings AS Stainless steel specifications (Stainless steel 303) AS-FE KE AS-FG AS-FG Use 1/8" tube. Made to Order AS-FP AS-FM Grease-free (Seal: Fluorine Coated) + Throttle Valve (Without Check Valve) X21 Lubricant: Vaseline X12 AS-D AS-T Ex.)
8 !4 !6 !7 !5 r !8 !4 !6 !7 !5 !1 AS-F !1 !2 TMH !2 !3 w ASD t y q i o e u t y q i o e u AS w AS-FE !0 KE !0 AS-FG AS-FG !9 AS-FP Meter-out type Meter-out type Meter-in type Meter-in type AS-FM Seal method: Face seal For G thread AS-D AS-T r !8 !4 !6 !7 !5 !1 ASP ASN !2 AQ w t y q i o e ASV AK !0 VCHC ASR ASQ u @0 Meter-out type Meter-in type Component Parts No.
5 2bit 6-7 2byte 8-11 4byte 0 IN5 IN4 IN3 IN2 IN1 IN0 1 FLGTH JOG(+) JOG(-) SETUP RESET DRIVE SVON HOLD 2 3 2 1 4 FG 5 2bit 20byte 6-7 2byte 8-11 4byte 12-13 2byte 14-17 4byte 18-19 2byte 0 IN5 IN4 IN3 IN2 IN1 IN0 1 FLGTH JOG(+) JOG(-) SETUP RESET DRIVE SVON HOLD 2 3 2 1 4 FG 5 2bit 6-7 2byte 8-11 4byte 36byte 12-13 2byte 14-15 2byte 16-17 2byte 18-19 2byte 20-21 (2byte) 22-23 2byte
AS131FG(3.2, 4, 6, 1/8", 5/32", 1/4"), AS231FG-01(3.2, 4, 6, 1/8", 5/32") are made of POM. 15-9-46 5 Speed Controller with One-touch Fitting Stainless Series, Elbow Type/Universal Type Series AS-FG Dimensions: Elbow Type Applicable tubing O.D. d (Hexagon width across flats) M5 type U10/32 type Applicable tubing O.D. d AS (Hexagon width across flats) ASP ASN AQ ASV AK ASS ASR Metric Size Inch
Symbol: FG (2-Position), Solenoid: S (Single), Voltage: 3 (24V DC), Option: Z (Indicator Light w/Surge Voltage Suppressor), Seal: Metal Seal, Subplate: A04 (Side Ported 1/2)
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): 250 or Less, Pipe Port Type: [Rc (R)] Rc, Port Size: 1/2, Pressure Rating(MPa
Material Note 1 2 3 4 5 6 7 8 9 10 PBT Brass Electroless nickel plated Brass Electroless nickel plated Steel wire HNBR NBR NBR Tool steel 519 Series AS1F-D Dimensions L4 D3 Applicable tubing O.D. d L3 D1 L2 M1 M1 L1 D2 Metric Size Inch Size Mass (g) Mass (g) 8 8.4 D1 38 L1 4.5 L2 26 L3 M1 1/8" d D2 D3 L4 Model d 8.4 D1 D2 D3 4.5 L2 38 L1 26 L3 L4 M1 Model AS3001F-11D AS3001F-09D AS3001F
8 !4 !6 !7 !5 r !8 !4 !6 !7 !5 !1 AS-F AS-F !1 !2 TMH !2 !3 w ASD t y q i o e u t y q i o e u AS w AS-FE !0 KE !0 AS-FG !9 AS-FP Meter-in type Meter-out type Meter-out type Meter-in type AS-FM Seal method: Face seal For G thread AS-D AS-T r !8 !4 !6 !7 !5 !1 ASP ASN !2 AQ w t y q i o e ASV AK !0 VCHC ASR ASQ u @0 Meter-in type Meter-out type Component Parts No.