High temp. cut off alarm ERR12 Low temp. cut off alarm ERR13 Unused Output failure alarm ERR15 D2 23 22 21 20 Upper temperature limit alarm WRN Lower temperature limit alarm WRN Thermostat alarm ERR14 DC power supply failure alarm ERR11 D3 23 22 21 20 External sensor failure alarm ERR18 Internal sensor failure alarm ERR17 During Auto tuning or auto tuning warning ERR19 Flow switch alarm
(Conforming to DIN) Clip Without indicator light AXT100-20-1 Rated voltage With indicator light 16.8 Voltage symbol Part no. AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 13.8 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V 1. It is able to change the cylinder port between side ported and top ported.
(b) OFF ON OFF 63.4% CDT = 100 ms 100 50 100 4.00 10.00 4.00 120 84 120 3000 4000 3000 20 50 20 1 50 60 50 1 50 60 50 1 0.20 0.15 0.20 1 0.20 0.15 0.20 2 20 30 20 2 20 30 20 2 0.10 0.05 0.10 2 0.10 0.05 0.10 (2) (a) PB06 GD2 4.00 [] PB08 PG2 120 [rad/s] PB09 VG2 3000 [rad/s] PB10 VIC 20 [ms] PB29 GD2B 10.00 [] PB30 PG2B 84 [rad/s] PB31 VG2B
. 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100A20 CH1 . 8-7 8.4.2 HRL200A20 CH1 . 8-7 8.4.3 HRL300A20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity . 8-9
mA, 7: 4..20 mA 3 Reserved 3 4..6 (Ch1 in) Analogue input or output range 3: 0..10 V, 4: 0..5 V, 5: 1..5 V, 6: 0..20 mA, 7: 4..20 mA 7 Reserved 0..2 (Ch0 out) Analogue input or output range 0 to 3: 0..10 V, 4: 0..5 V, 5: 1..5 V, 6: 0..20 mA, 7: 4..20 mA 3 Reserved 4 4..6 (Ch1 out) Analogue input or output range 0 to 3: 0..10 V, 4: 0..5 V, 5: 1..5 V, 6: 0..20 mA, 7: 4..20 mA 7 Reserved 0:
Low noise 60 ZK2A07 (Silencer exhaust) ZK2G07 (High-noise reduction silencer exhaust) 46 dB (A) 1 50 1 Nozzle size: 0.7 (Under SMCs measurement conditions) 40 Noise level [dB (A)] 30 Reduces high-frequency range from 2000 to 20 Hz. 20 10 0 200 2000 20 Frequency [Hz] Suction flow Improved by up to approx. 20% Max. suction flow [L/min (ANR)] Nozzle size Exhaust type 40 80 Approx. 20% High-noise
DC24V 2. 20 3. 4. 5. 6. 7. 8.
35oC 20 15 10 5 0 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Fig. 9-18 Cooling Capacity (HRL200-W-40 CH1) HRL Series 9.4 Cooling Capacity 9-17 HRX-OM-X037 Chapter 9 Documents 9.4.13 HRL100/200-W-40 CH2 3.0 2.5 Cooling capacity [kW] Ambienttemperature 45oC or less 2.0 (Max. 1.5 kW) 1.5 Rated 1.0 kW 1.0 0.5 0.0 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Up to
Direct Operated 2 Port Solenoid Valve New New (To be acquired) RoHS Air Air Medium vacuum Medium vacuum Medium vacuum Medium vacuum Oil Water Large flow rate Compact Lightweight Weight Flow rate Height 10% Smaller 10% Smaller 20% More flow 20% More flow 30% Lighter 30% Lighter (Size 1) (Size 1, Aluminum body) (Size 1) Comparison with SMC conventional model 1 Applicable to conduit type only
2-M3 x 0.5 depth 4 8.45 20 Piping port M5 x 0.8 depth 5 6.4 Piping port R, NPT 1/4 18.35 3.5 12.4 7 7.8 25.1 2.5 10.7 2.6 8.45 10.1 12.4 30 15.2 14.5 22 Piping port G 1/4 Piping port G 7 For General Fluids High Precision Digital Pressure Switch Series ZSE50F/ISE50 Dimensions Bracket A A 30 20 20 45 55 4.5 11.5 40 15 4.5 6.5 1.6 20 41.5 ZS-24-A Bracket A View A Bracket D A 30 20 20 45 55
High Precision, Digital Pressure Switch for General Fluids Dimensions Bracket A A 30 20 ZSE ISE 20 PSE 45 Z I SE3 55 4.5 11.5 40 15 PS 4.5 Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6.5 1.6 ZSP 20 41.5 ZS-24-A Bracket A View A ISA2 IS Bracket D ZSM
2-M3 x 0.5 depth 4 8.45 20 Piping port M5 x 0.8 depth 5 6.4 Piping port R, NPT 1/4 18.35 3.5 12.4 7 7.8 25.1 2.5 10.7 2.6 8.45 10.1 12.4 30 15.2 14.5 22 Piping port G 1/4 Piping port G 7 For General Fluids High Precision Digital Pressure Switch Series ZSE50F/ISE50 Dimensions Bracket A A 30 20 20 45 55 4.5 11.5 40 15 4.5 6.5 1.6 20 41.5 ZS-24-A Bracket A View A Bracket D A 30 20 20 45 55
20 IS10M-30 IS10M-40 Residual pressure relief 3 port valve Note 3) Note 1) Contact SMC regarding pressure gauge supply for psi unit specifications.
20 IS10M-30 IS10M-40 Residual pressure relief 3 port valve Note 3) Note 1) Contact SMC regarding pressure gauge supply for psi unit specifications.
Never use pressure sensors in the presence of inflammable or explosive gases. 20 Series PSE Specific Product Precautions 2 Be sure to read before handling. Refer to pages 17 through 19 for general safety instructions and common precautions, and to pages 20 through 22 for specific product precautions.
Insert each lead wire into the corresponding connector number by following the chart provided below. 20 mm or more Connector no.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Residual voltage 1 V or less (with load current of 80 mA) Response time 2.5 ms (Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms) ZSP Short circuit protection With short circuit protection 0.5%F.S.
Solenoid: No.3 Solenoid, Body Size: 9 (50A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: F (G), Voltage: 6 (12VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: S (Surge Suppressor)