Flange Size: 40, Flange Type: KF(NW), Port Direction: w/Indicator, Rear Flange Surface, Temperature: 5 to 150°C, No Heater, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/Indicator, Rear Flange Surface, Temperature: 5 to 150°C, with 100°C Heater, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/Indicator, Rear Flange Surface, Temperature: 5 to 150°C, with 120°C Heater, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Flange Size: 40, Flange Type: KF(NW), Port Direction: G (w/Indicator, Rear Flange Surface), Temperature: H0 (5 to 150°C, No Heater), Version: 2 (Refresh)
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150°C
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
For HRR050-AF-20/40G thread adapter set 1 set For HRR050-AN-20/40NPT thread adapter set 1 set 1 In the case of option Z, not included.
Pivoting bracket 40g DIN rail mounting bracket Single unit Standard / Directive CE (EMC directive 2014/30/EC) Note 1) Value measured with probe of 1,000M and 5pF.
Cylinder stroke (mm) Bore size (mm) 100 75 50 25 12 0.48 0.44 0.4 0.36 20 0.74 0.68 0.62 0.56 CEP1 CEP1 Note) For the type with a sensor cable length of 0.5m and without connector (CE1-Z), 40g is subtracted from the weight shown above. For the type with a sensor cable length of 3m and connector (CE1-L), add 160g to the weight shown above.
the lead wire assembly with connector) Manifold Base Stations 1 2 3 4 5 6 7 8 9 10 11 12 Weight g 16 22 28 34 41 47 53 60 66 72 79 85 Calculation Formula for Weight of the Manifold Type (Weight of the single unit x Number of stations) + (Weight of pressure sensor or vacuum pressure switch x Number of stations) + Manifold base Calculation example: With pressure sensor, 5-station manifold 40g
500VDC) between external terminals and case 10 to 500Hz at whichever is smaller, amplitude 1.5mm or acceleration 98m/s(10G), in X, Y, Z directions for 2hrs. each 980m/s in X,Y,Z directions 3 times each Connector type Grommet type Heat resistant vinyl cord 1.55, 0.31mm,4 wire Oil resistant vinyl heavy duty cord -21, -23: 3.5, 0.14mm,4 cores -22, -24: 3.5, 0.15mm, 5 cores Lead wire Weight 40g
Frequency Port size (Nominal size) Piston style 0.15 to 1.0MPa 5 to 60C (No freezing) VM/VR Red Green Orange Rc(PT) (6A) 40g VH 300 c.p.m or less R(PT) (6A) 1 8 1 8 Weight 6g Construction/Component Parts Construction/Component Parts w q Description Aluminum alloy Material Notes No. w q Description Brass Material Notes No.
// PV=PD ZB11-K1PVPD ZB0020-K1/ PV ZB11-J1PV ZB0010-J1/ PVPD ZB21-Q1L(O)-P PVPD ZB0020-K1L(O)-P 1 3 1 3 35 - No.ZB-OM00301 // PV=PD ZZBZB31-K1D U / PVPD ZZB-SM5 ZB31-Q1L(O)E F D U / PVPD ZZB-SM5 ZB0030-K1L(O)E F D U 36 - No.ZB-OM00301 ZB1/2-K1 46 ZB3-K11 40 g ZB1-PS-A 5 ZB1-ZS-A Assy 14 1 2 3 4 5 6 7 8 9 10 11 12 g 16 22 28 34 41 47 53 60 66 72 79 85 ++ 5 40g
Heater: Indicator: 418 B XLA/XLA V Series Aluminum High Vacuum Angle Valve Dimensions XLA/Air operated (b) E C D C E E Fn (KF flange) B (K flange) Fd (a) Heater (Option) (c) Auto switch (Option) H G A A (mm) A B C D Fn Fd G H E Note 1) Model XLA-16 XLA-25 XLA-40 XLA-50 XLA-63 XLA-80 XLA-100 XLA-160 40 17 30 1 38 40 103 39 26 40 12 1 48 50 113 63 41 55 11 2 66 65 158 68 52 75 11 2 79
Heater: Indicator: 418 A XLA/XLA V Series Aluminum High Vacuum Angle Valve Dimensions XLA/Air operated (b) E C D C E E Fn (KF flange) B (K flange) Fd (a) Heater (Option) (c) Auto switch (Option) H G A A (mm) A B C D Fn Fd G H E Note 1) Model XLA-16 XLA-25 XLA-40 XLA-50 XLA-63 XLA-80 XLA-100 XLA-160 40 17 30 1 38 40 103 39 26 40 12 1 48 50 113 63 41 55 11 2 66 65 158 68 52 75 11 2 79
Inverter Type Circulating Fluid Temperature Controller Thermo-chiller Small Basic Type Peltier-Type Chiller Thermo-con/ Rack Mount Type Air-cooled Series HRSH Series HRSE Series HECR P .934 P .970 P .990 High Vacuum Equipment Pneumatic Instrumentation Equipment Aluminum High Vacuum Angle Valve Normal Close High Vacuum Solenoid Valve Pneumatic Instrumentation Equipment Series XSA P .1034 Series XLA
XLAV 5 Series XLA, XLAV High Vacuum Angle Valve Specifications Model XLA(V)-50 XLA(V)-63 XLA(V)-80 XLA(V)-16 XLA(V)-25 XLA(V)-40 Valve type Normally closed (pressurize to open, spring seal) Non-corrosive gas for aluminum alloy (A6063) and SUS304/316 Fluid 5 to 60C (41 to 140F) [high temperature type: 5 to 150C (41 to 302F)] XLA Operating temperature C 5 to 50C ( 41 to 122F) XLAV Atmospheric
Chemraz is a registered trademark of Greene, Tweed Technologies, Inc. 4 XLA/XLA V Series Specifications Model XLA(V)-16-2 XLA(V)-25-2 XLA(V)-40-2 XLA(V)-50-2 XLA(V)-63-2 XLA(V)-80-2 Valve type Normally closed (Pressurize to open, Spring seal) Fluid Inert gas under vacuum Operating temperature [C] XLA 5 to 60 (High-temperature type: 5 to 150) XLAV 5 to 50 Operating pressure [Pa(abs)] 1 x 106
XLAV 5 Series XLA, XLAV High Vacuum Angle Valve Specifications Model XLA(V)-50 XLA(V)-63 XLA(V)-80 XLA(V)-16 XLA(V)-25 XLA(V)-40 Valve type Normally closed (pressurize to open, spring seal) Non-corrosive gas for aluminum alloy (A6063) and SUS304/316 Fluid 5 to 60C (41 to 140F) [high temperature type: 5 to 150C (41 to 302F)] XLA Operating temperature C 5 to 50C ( 41 to 122F) XLAV Atmospheric