Valve Type: XMC (Angle Type, Double Acting, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: L (w/o Indicator, Rear Flange Surface; Indicator Std, Rear Flange Surface), Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch), Seal Material
Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: A (w/Indicator, Flange Side; w/Indicator, Rear Flange Surface), Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch), Seal Material: XN1
Valve Type: XMD (Angle Type, 2 Stage Control, Single Acting, Bellows, O-ring Seal), Flange Size: 50, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C), Suffix: , Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch
Valve Type: XYD (In-line Type, 2 State Control, Single Acting, Bellows, O-ring Seal), Flange Size: 63, Flange Type: D [K (DN)], Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C), Suffix: , Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto
Valve Type: Normally Closed, Bellows Seal, Flange Size: 16, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: EPDM
Flange Size: 16, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: EPDM
Valve Type: Angle Type, 2 Stage Control, Single Acting, Bellows, O-ring Seal, Flange Size: 63, Flange Type: D [K (DN)], Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: -, Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (
Valve Type: Angle Type, Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std.
Valve Type: Angle Type, Normally Closed, Bellows Seal, Flange Size: 16, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: -, Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch), Seal Material
Valve Type: Angle Type, Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: -, Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch), Seal Material
Valve Type: Angle Type, Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Port Direction: w/Indicator, Right Flange Surface, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: -, Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch), Seal Material: EPDM 2101-80, Seal Replacement: 2, 3
Valve Type: Angle Type, Double Acting, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Port Direction: w/o Indicator, Rear Flange Surface; Indicator Std, Rear Flange Surface, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: -, Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch), Seal Material: EPDM
Valve Type: Angle Type, Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Port Direction: w/Indicator, Flange Side; w/Indicator, Rear Flange Surface, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: -, Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch), Seal Material: EPDM 2101-80
Valve Type: Angle Type, 2 Stage Control, Single Acting, Bellows, O-ring Seal, Flange Size: 50, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: 5 to 150°C, Suffix: -, Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch), Seal
Valve Type: XYD (In-line Type, 2 State Control, Single Acting, Bellows, O-ring Seal), Flange Size: 63, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C), Suffix: , Auto Switch: w/o Auto Switch & Built-in Magnet, Lead Wire: 0.5m (or None in the Case of No Auto Switch), Number: None (w/o Auto Switch
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed), Non-standard Indicator: X (Non-standard Indicator), Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material