Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
L5 A2 L6 T Inch Size A1 A2 Weight (g) 17 d 1/8" Model H T D1 8.4 D2 D3 D4 L1 L2 L3 L4 L5 L6 M1 ASD230F-U10/32-01D ASD230F-U10/32-03D ASD230F-U10/32-05D ASD230F-U10/32-07D ASD330F-N01-05SD ASD330F-N01-07SD ASD330F-N01-09SD ASD430F-N02-07SD ASD430F-N02-09SD ASD430F-N02-11SD ASD530F-N02-07SD ASD530F-N02-09SD ASD530F-N02-11SD ASD530F-N03-07SD ASD530F-N03-09SD ASD530F-N03-11SD ASD630F-N04-11SD
L5 A2 L6 T Inch Size A1 A2 M1 T Model H d D1 L2 L5 L6 D3 D4 L1 D2 L4 L3 ASD230F-U10/32-01D 1/8" 8.4 12.9 29.4 17.5 ASD230F-U10/32-03D 5/32" 9.3 27.4 7.8 10-32 UNF 8 0.7 31 11.7 9.6 10 4.7 30.7 ASD230F-U10/32-05D 16.5 3/16" 11.4 35.2 23.3 ASD230F-U10/32-07D 13.5 1/4" 12 32.6 20.7 ASD330F-N01-05SD 16.5 3/16" 11.6 38.5 14 23.9 38.9 ASD330F-N01-07SD 31.6 10.6 NPT 1/8 12.7 17 35.6 1.2 7.2 14.2
-01ST AS221F-01-04ST 1/8" 8.4 4 20.4 27.5 9.3 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-N01-03ST AS221F-01-06ST 13.5 12 R 1/8 14.2 7 35.6 1.5 31.6 6 11.6 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-N01-05ST AS221F-01-08ST NPT 1/8 12.7 14.2 7 35.6 1.5 31.6 18.5 25.3 32.4 8 15.2 AS221F-N01-07ST AS221F-01-10ST 1/4" 13.2 23.9 31 18.5 15 21 33.1 40.2 10 18.5 AS221F-N01-09ST AS221F-02-04ST 15 5/16" 15.2 25.3
A2 L5 A1 A2 D1 D1 T T Metric Size L4 L5 A1 A2 M Max.
L5 L5 A1 A2 D1 D1 A2 T T Inch L4 L5 A1 A2 M MAX.
D1 A2 T1 Metric Size L4 Weight (g) AS A2 A1 M L3 L2 L1 d T1 D1 D2 H2 H1 Max.
-P10-N01 Blanking plate kit 136114A 136214A (plate, screws, and o-ring) Manifold base, 13612-*-N 13622-*-N Common IN (A1, A2) Manifold base, 13613-*-N 13623-*-N Individual IN (B1, B2) * Denotes number of stations: 2~10 available. 10 10 station NARM2000-4B2 Note1) In case of A1 and B1, a pressure gauge or a plug is mounted at the body side, while in case of A2 and B2, at the manifold side.
Model no. of NPT thread is AN101-N01 and AN110-N01. It can operate in temperatures between 10 to 150C if there is no risk of the moisture in the air freezing.
ZS-46-3L M5 Lead wire with connector (3-core, 2 m lead wire) A1 Bracket A (Vertical mounting) Piping port L Without waterproof cover R1/8 ZS-46-A2 01 R1/8 Piping adapter ZS-46-N1 A2 Bracket B (Horizontal mounting) u Option 3 Symbol Operation manual1 Calibration certicate1 Nil Y K T NPT1/8 N01 NPT1/8 Piping adapter ZS-46-N2 1 All texts are in both English and Japanese.
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]