Operating humidity range P.3.14-3 Vacuum breaking pressure Full scale Operating indicator light P.3.14-5 P.3.14-4 Voltage resistance Full span Operating pressure range Operating temperature range Operating voltage G W Orifice Gas contact part Wind comparator mode P.3.14-5 P.3.14-3 P Grommet Panel mounting H Z Peak indication part P.3.14-4 PNP output Hysteresis Zero out (Zero

PSE200 PSE201 Model NPN open collector PNP open collector Output specifications 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polariry protection) Power supply voltage 55 mA or less (Current consumption for sensor is not included.) Current consumption [Power supply voltage] 1.5 V 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]

Process Pump (Diaphragm Pump) PB Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids o t p m s l a i PA z P e Built-in solenoid valve only RoHS Smaller, lighter, 25% reduction in volume Smaller, lighter, 25% reduction in volume

This is a legacy product, and replaced byISE20B-Y-P-N01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .26455 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

This is a legacy product, and replaced byZSE20B-Y-P-N01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay