SMC Corporation of America
Elite Part Number Search
Search Results "CDLSG200-1100"

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.02 to 0.7, Specification: Without magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.01 to 0.7, Specification: Without magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.01 to 0.7, Specification: Without magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Actuation typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]HorizontalVerticalLEFB40S4300, 400, 500600, 700, 800900, 1000, (1100

Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, GUIDED CYLINDER, D81, 1100 lb

Actuation typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]HorizontalVerticalLEFB40S4300, 400, 500600, 700, 800900, 1000, (1100

Model: 21 (2190 l/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: N (NPT), Port Size: 2 [1/4 (1100, 2100, 3100)], Bracket: None, Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 4 (PSI)

Model: 11 (800 l/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 5 (Analog Output 4~20mA Source Type), Thread: N (NPT), Port Size: 1 [1/8 (1100)], Bracket: None, Cable Connector: N (w/o Cable Connector)

Model: 21 (2190 l/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 5 (Analog Output 4~20mA Source Type), Thread: N (NPT), Port Size: 2 [1/4 (1100, 2100, 3100)], Bracket: None, Cable Connector: N (w/o Cable Connector)

Model: 11 (800 l/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 1 (12~15VDC), Input Signal: 2 (Voltage Style 0~5VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: N (NPT), Port Size: 2 [1/4 (1100, 2100, 3100)], Bracket: None, Cable Connector: N (w/o Cable Connector), Pressure Display Unit: 5 (kPa)

Model: 11 (800 l/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: N (NPT), Port Size: 1 [1/8 (1100)], Bracket: C (L Bracket), Cable Connector: N (w/o Cable Connector), Pressure Display Unit: 4 (PSI)

Model: 21 (2190 l/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 3 (Switch Output PNP), Thread: N (NPT), Port Size: 2 [1/4 (1100, 2100, 3100)], Bracket: None, Cable Connector: N (w/o Cable Connector), Pressure Display Unit: 4 (PSI)