Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 150 (1 1/2"), Stroke: 0200 (2"), Cushion: w/o Rubber Bumper, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Type: Pneumatic, Mounting Style: A (Bottom Mounting Style), Bore: 20mm, Stroke: 50mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod End Bracket: None, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)
Model: MSQ, Precision: B (Basic), Size: 200, Suffix: R (Shock Absorbers), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. [Or None in the Case of No Switch], Thread Type: XN (NPT 1/8)
Model: MSQ, Precision: B (Basic), Size: 100, Suffix: A (Adjuster Bolt), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. [Or None in the Case of No Switch], Thread Type: XN (NPT 1/8)
Model: MSQ, Precision: B (Basic), Size: 70, Suffix: A (Adjuster Bolt), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. [Or None in the Case of No Switch], Thread Type: XN (NPT 1/8)
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
Bore Size: 16mm, Port Thread: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 10mm, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)
Style: B (Standard Type-Air Cushion), Bore Size: 32mm, Port Thread: Rc: ø25, ø40, ø50, ø63/M Thread: ø16, Stroke: 300mm, Stroke Adjusting Unit: L (Both Sides Shock Absorber for Low Load), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 050 (1/2"), Body Option: Standard (Rod End Female Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93V,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93V,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93V, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Specification: Built-in magnet, Support bracket: Without mounting bolt, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Specification: Built-in magnet, Support bracket: Without mounting bolt
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Port