Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 300mm, Option: K [Heat Resistant Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Without magnet
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Fittings & Tubing Air Cylinders Rotary Actuators 1 3 4 6 Piping port size M3 x 0.5 M5 x 0.8 Fluid Air Action Double acting Operating pressure 0.15 to 0.7 MPa Proof pressure 1.05 MPa 10 to 60C Ambient and fluid temperature Piston speed 30 to 200 mm/s Rubber bumper (Rubber stopper) Rubber bumper Cushion Rubber bumper (Without adjuster) No (Metal stopper) Lubrication Non-lube Stroke adjuster
Dimensions Option Port size A D OUT IN C B Metal bowl Metal bowl with level gauge Without drain cock B B B Drain cock barb fitting Drain cock thread piping With drain guide E Maintenance space B B B 1/4 Barb fitting Applicable tubing T0604 1/4 Width across flats 17 Option/Dimensions N.O N.C B (With auto drain) Model A B C D N.O N.C E AF800 AF900 150 200 408 488 33 46 140 170 448 528 448 528
size (mm) 6 Air cylinder Rotary actuator Air gripper Directional control valve Fittings & Tubing Pressure switch Clean gas filter Flow control equipment Filter, Pressure control equipment Air preparation equipment 1 3 4 6 Piping port size M3 x 0.5 M5 x 0.8 Air Fluid Double acting Action 0.15 to 0.7 MPa Operating pressure 1.05 MPa Proof pressure 10 to 60C Ambient and fluid temperature 30 to 200
Please delete the unnecessary part. 32 Add 3mm to each A dimension of the standard style (double acting/single rod) on p.1.4-21. 40 1.4-82 World Wide QS\E Support... North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics lnc. (Milwaukee) SMC Pneumatics lnc. (Richmond) SMC Pneumatics Inc.
The used of turbine oil at temperatures lower than 0C leads to increased viscosity and may cause the valve to malfunction. d n i n i W g c e t i r o i d n e p a t e p i P Leakage Voltage It must be noted that when connecting C-R element parallel to switching element, leakage current flows through C-R element and the leak voltage increases. 2 thread to be left exposed Clamping Torque Switching