SMC Corporation of America
Elite Part Number Search
Search Results "IS3100-L1"

Auto switches are integrated as standard.Magnetically coupled rodless cylinder , Direct mount type, with switch rail , Bore sizes *: 6, 10, 15, 20, 25, 32, 40, 50, 63 , Maximum operating pressure: 0.7MPa , Ambient temperature: -10 to 60C , Variety of auto switches available, SEAL KIT, ACTUATOR, CY3B MAGNETICALLY COUPLED CYL, L1, 32MM CY3B PART, .06072 lb

32MM CG PART, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, L1, 32MM CG PART, 0.22046 lb

Double acting, single rod CG5-S cylinder, All stainless steel external parts, Special scraper prevents water from entering cylinder, Bore sizes (mm): 20, 25, 32, 40, 50, 63, 80 and 100, Auto switch capability, SEAL KIT, ACTUATOR, CG5 CYLINDER, STAINLESS STEEL, L1, 32MM CG5 PART, .03960 lb

non-rotating function without having to use a rod with flats, offering increased bearing and seal life.Single acting, spring return/extend, plate cylinder , Possible to mount without brackets , Auto switch mounting grooves prevent projection of auto switches , Auto switches can be mounted in 4 directions , Strokes up to 20mm, Series Catalog, SEAL KIT, ACTUATOR, MU COMPACT CYLINDER, L1

mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes *: 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke range *: 5 to 100, Port threads: M *; Rc, NPT or G * , Auto switch capable, KIT, SEAL NON-ROTATING, ACTUATOR, CQ2 COMPACT CYLINDER, L1

Part Number Description: FOOT KIT XB12   Product Line: A   Product Line Description: ACTUATOR   Family Code: 425   Family Description: CM2 ROUND BODY CYLINDER   Class Code: L1   Part Code: 2   Reference Code:  K   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number

Foot bracket, Applicable series: NCM, Applicable bore size *: 3/4, 7/8, 1 1/16, 1 1/4, 1 1/2, BOOT - NCM-K, ACTUATOR, NCM ROUND BODY CYLINDER, L1, 1.25 INCH NCM PART, .38486 lb

Part Number Description: SCRAPER CY2S   Product Line: A   Product Line Description: ACTUATOR   Family Code: 474   Family Description: CY2B GUIDED CYLINDER   Class Code: L1   Part Code: 2   Reference Code:  J   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number

Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p, TUBE, B MOUNT, W TYPE, ACTUATOR, CQ2-Z COMPACT CYLINDER, L1, 32MM CQ2-Z PART

Dimensions for installation L: Dimensions n: Number of stations L n 2 3 4 5 6 7 8 9 10 L1 133.4 166.4 199.4 232.4 265.4 298.4 331.4 364.4 397.4 L2 117 150 183 216 249 282 315 348 381 -11No.EX-OMY0021 Wiring Select the appropriate cables to mate with the connectors mounted on the SI unit.

View A L1 L2 L3 PE Inlet of the power supply cable Note: Prepare a cable tie. Fasten the power cable to the mount on the base with the cable tie.

View A PE L1 L2 L3 power supply cable Fig. 3-9 Wiring of power supply cable * Connect an over current protection to the power cable connected to the equipment to avoid hazard. 3.3 Installation HRL Series 3-16 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.3.4 Contact input/output communicatin wiring Be sure to lock out and tag out the breaker of the facility power supply (the users machine

View A L1 L2 L3 PE Inlet of the power supply cable Mount for cable tie Note: Prepare a cable tie. Fasten the power cable to the mount on the base with the cable tie.

L1 L2 L3 Recommended torque: 12.5 Nm (R) (S) (T) Earth bar Main breaker Figure 3-9 Connection of Power Cable and Grounding Terminal [Tips] See Table 3-1 Power Cable and Main Breaker (The Product) on page 3-7 for torque value. 10. Attach the breaker cover to the breaker. 11. Close the front door. 12. Connect the power cable to the power breaker on customer side (primary side).

Required Gap (mm) Model L1 L2 L3 L4 L5 L6 MHM-16D 16 5 MHM-25D 36 34 1 1 1 1 MHM-32D 50 24 MHM-50D 23 25 80 41 Auto Switch Connections and Examples Sink Input Specifications Source Input Specifications Connect according to the applicable PLC input specifications, as the connection method will vary depending on the PLC input specifications. 13 - Examples of AND (Series) and OR (Parallel) Connections

Please refer to the individual catalog for dimensions when other manifolds are connected. n m L 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 45 55.5 66 76.5 87 97.5 108 118.5 129 139.5 150 160.5 171 181.5 192 202.5 213 L2 89.8 110.8 131.8 152.8 173.8 194.8 215.8 236.8 257.8 278.8 299.8 Wiring (for power supply, communication and input) and piping are installed on only one side of the product

N_m L 0 1 2 3 4 5 6 7 8 L1 45 55.5 66 76.5 87 97.5 108 118.5 129 L2 89.8 110.8 131.8 152.8 173.8 194.8 215.8 236.8 257.8 (mm) Wiring (for power supply, communication, input and output) and piping are carried out on one side only.

Mounting the side supports Number of side supports : N (MY-S50A) Stroke N L1 (mm) Bolt Max. tightening torque [Nm] (QTY.) 200 6 300 6 400 6 500 6 600 8 15 M8 x 1.25 12.5 800 8 1000 10 1200 12 1500 14 Secure the side supports using the support spacing (L) in the table above. When mounting wit the side supports, use in combination with the pin on the bottom of the body.

Using a tightening torque higher than the specified torque may cause malfunction, and using a lower tightening torque may displace the work piece or cause it to drop off. 1 Body mounting from the bottom / tapped type Screw material SUS Screw dimensions M3 x 0.5 Recommended tightening torque [Nm] 0.48 to 0.63 L1 (Maximum screw-in depth) [mm] 4.6 L2 (Plate thickness) [mm] 2.1 2 Body mounting