SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-M5"

x 0.8, NPTF 1/8, M5 x 0.8 Port size R 1/8, M5 x 0.8 NPTF 1/8, M5 x 0.8 ZX ejector mounted type: M5 x 0.8 Enclosure IP40 Note 1) Instant pressure supply of 0.5 MPa has no influence on the switch.

200W/60 400W/60 Electric specification Motor type AC servo motor (AC100/200V) Motor type S2,S3,S4: Incremental 17bit encoder (Resolution: 131072 p/rev) Motor type T6,T7,T8: Absolute 22bit encoder Resolution: 4194304 p/revFor LECSB2-T, LECSS2-T Encoder Note7) Motor type T6,T7,T8: Absolute 18bit encoder (Resolution: 262144 p/revFor LECSC2-T Max. 725 Power [W] Note5) Max. 445 Max. 1275 Type

[Torque : 0.1Nm{1kgf/cm2} or less] L P Connector housing Socket While pressing, turn in the direction of the arrow. If you do not turn, the mechanism does not lock in position. Lead wire Hook Plug Connector Type Lead Wire Length Standard length is 300mm, but the following lengths are also available.

Stroke + 126 3.3 24 1 5 3 5.8 8 3 21 59 F 5H9 +0.030 0 depth 5 T-slot dimensions (2/1) 29.5 5H9 +0.030 0 depth 5 6 T-slot 4-M5 x 0.8 (for body mounting) thread depth 8 (11.5) 38 E Refer to page 299 for mounting.

D(Finger closing port) M5 x 0.8 (Finger closing port) M5 x 0.8 20Auto switch mounting groove (4 locations) 4-M6 x 1 (Piston rod and rack screw) Width across flats 10 (4 locations) Closed E 4-M5 x 0.8 through Open F (Thread for mounting attachment) (mm) A B C D E F G H 40 70 90 J 98 152 192 Model MHL2-16D MHL2-16D1 MHL2-16D2 45 75 95 60 90 110 28 58 78 68 110 130 98 170 210 128 200 240 26

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: -, Option 3: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: -, Option 3: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: -, Option 3: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m)

Refer to Chapter 3, Product Specific Precautions 3 (P. 7 to 8) and Chapter 5, Construction and Dimensions (P. 11) for maintenance parts. Parts with the indication of "Maintenance part" can be replaced. 4. SMC specified parts should be used for service. Refer to the Construction / Maintenance parts table. 5.

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -

Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -

S 1 0.53 28 2.511 48 418 6.531.5 6.531.5 10 FKM1.310 3/s Pam -11 FKM1.310 KFNW KFNW KDN SUS316L,SUS304,FKM 2 MPa G 0.40.7[ ] 46 200 360 660 1350 3000 5150 3 3 cm O.5MPa 2.5 12 15.5 30 42 54 54 M5 Rc1/8 Rc1/4 [kg] 0.5 1.2 1.8 3.4 5.6 11.5 20 1 2 [Y-VAC2] 5 3 1 1mm 32 L/SP=0.1MPa 30 6 P11) 28 XLD-100 XLD-160 L/s () P=0.1MPa 26 24 22 20 XLD-63 XLD-80 18 16 14 XLD-50 12 10

less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ionic silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Should not be Should not be Referential detected any detected any item Ammonium ion [mg/L] 0.1 or less 1.0 or less Residual chlorine [mg/L] 0.3 or less 0.3 or less Free carbon dioxide [mg/L]

Supply pilot air higher than 0.25 MPa to P1 port Piping Inlet side (supply side): P port, Outlet side (exhaust side): A port Supply pilot air higher than 0.25 MPa to P1 port. PA VNH 12(P1) 12(P1) Nozzle 2(A) 1(P) PAX Nozzle 1(P) 2(A) 3(B) Stop valve Tank Coolant pump PB Tank Coolant pump For reducing load to pump, coolant liquid is returned from B port to tank each time.