Connector no. 1 2 3 4 Wire core color Air tubing For PSE300 (ZS-28-C) Brown (DC(+)) Not connected Blue (DC(-)) Black (OUT: 1 to 5 V) Resin pipe Part-A 1 2 3 4 Controller Handling Warning 1 2 3 4 1. Do not drop, bump, or apply excessive impact (100 m/s2) while handling.
P = 8.2 29 8.2 x 7 = 57.4 P = 8.2 4 3 105 15 *5 5 6 7 8 7.5 4.5 25H8 (10) 5.5 (10) 30H8 45 45 1 2 3 1 12 P=45 8 P=30 2 11 4 7 10 3 22.5 5 6 6 7 8 9 4 5 4-M3 x 0.5 thread length 8 P.C.D.48 51 46 2-M4 x 0.7 thread length 8 P.C.D.43 Mounting Brackets/Flanges MQR2-F MQR4-F 2-8 counter bore depth 3 2-4.2 through P.C.D.38 4-3.5 drill through 17 drill through 4-3.5 through 22 drill through 2-3.2
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Use a wire 3 m or shorter between the sensor and amplifier. If the sensor cable length exceeds 3 m, the CE marking does not apply to the auto switch. Although wire length of power supply/output cable should not affect switch function, use a wire 100 m or shorter. 3. Take precautions for the internal voltage drop of the switch.
Cylinder Position of rotational axis: Parallel side b and Position of rotational axis: Through the center of diameter and gravity through the center of gravity a b a r 2 3 2 2 a r + a I = m 12 I = m 12 3. Thin rectangular plate (Including 8.
Remove the excess sealant. 3. Insufficient tightening may loosen threads, or cause air leakage. 4.
Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, press applications, or safety equipment. 3.
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: -, CE Compliant: -
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -