Pressure Control Equipment (c) Good condition (d) Bad condition (e) Good condition (f) Bad condition Fig. 5 Tightening condition 7. Adjustment Method for Mounting Other Elements 7-1.
(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.
Material Cover Front rim Retaining rim Description Part no. includes M3 X 8 tapping screws (2 pcs.)
710 Clean Speed Controller with One-touch Fitting Elbow Type AS-FPQ/FPG Series RoHS AS-F Model TMH AS-FPQ/Brass (electroless nickel plated) Elbow type Port size Applicable tubing O.D.
710 Clean Speed Controller with One-touch Fitting Elbow Type AS-FPQ/FPG Series RoHS AS-F Model TMH AS-FPQ/Brass (electroless nickel plated) Elbow type Port size Applicable tubing O.D.
ID AMG Accessory (Option) HAA7 HAA7 HAA15 HAA22 HAA37 Auto-drain Applicable model AFF Working Principle HAA7-F HAA7-S HAA15-F AD402-03 HAA15-S HAA22-F HAA22-S HAA37-F AD402-04 Dust-protecting filter Mounting bench AM HAA37-S Inlet side air (HOT AIR) Push button switch Pilot light The accessories should be mounted by user. Misc.
Model number: HRS0-F-0 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
TA DL2 TF TG A S + Stroke H NA F ZZ + Stroke Section TA With non-locking type manual override (suffix N) With locking type manual override (suffix L) HN HR MO RF WL WL KA 0.1 C 8-J NA (mm) Stroke range Bore size (mm) A AL B1 C D DL2 E F GA GB H H1 HR HN (max.)
F G(PF) Dust Tight/Jet Proof (IP65) Optional IP65 model is available on valves with DIN connector electrical entry. How to Order Valve (Applicable to VQZ2000/3000 rubber seal) VQZ3151 5YZB 03 W IP65 rated No (Standard) (1) IP65 reted W Note 1) The pilot exhaust of the IP65 valves is common with main valve exhaust.
Black 0 V G Shield Connector pin arrangement A phase output pulse G A DB phase output pulse F B H E D C -X Counter value 0 1 2 3 4 3 2 1 699
200 V Black COM (0 V) G Shield Data A phase output pulse Connector pin arrangement B phase output pulse G A F B H E D C 0 1 2 3 4 3 2 1 Counter value 10-12-55
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
Model number: HRS040-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
Model number: HRS050-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
HRS090 Series 2.1 Precautions for communication 2-1 HRX-OM-T004 Chapter 2 Contact input/output communication 2.2 Communication specification Table 2.2-1 DIO Communication specification Item Specification Connector type M3 terminal block Contact input Insulation method Photo coupler signal Rated input voltage DC24V Input voltage range DC 21.6V to 26.4V Rated input current 5mA TYP Input impedance
Unused bit is fixed to 0. 4.10 Register Map HRSH Series 4-20 HRX-OM-R028 Chapter 4 MODBUS communication function 4.10.5 Circulating fluid set temperature The circulating fluid set temperature can be set by specifying the circulating fluid set temperature with the selected temperature unit (C or F) during SERIAL mode.
e. f. -37- 6.5 (LEFBLEFS -(A) (-(B)) A B LEF16 M2.5x5 LEF16 M2.5x16 LEF25 M3x6 LEF25 M3x20 LEF32 M3x6 LEF32 M4x30 LEFS40 M3x6 LEFS40 M4x35 -38- 7. No. 1) 1 / /P30 4.
M1 M2 2 Series CYP Dimensions T Y Depth ED T L E F PA K 4-MM 4-Counter bore dia.