OUT1 ON : Green OUT1 OFF: Red -30No.PS-OMU0009-D [F 2] Setting of OUT2 Page 36 Same setting as [F 1] OUT1.
32 40 50 63 80 100 NA P S TA TB ZZ 11 11 77 1/8 24 114 Up to 200 11 11 77 1/8 29 119 Up to 300 11 11 79 1/8 35.5 121 Up to 300 12 12 87 1/8 44 139 Up to 300 13 13 102 1/4 55 162 Up to 300 13 13 102 1/4 69 162 Up to 300 122 3/8 80 196 Up to 300 122 1/2 100 196 Up to 300 13 Smooth Cylinder Series CA2Y 40, 50, 63, 80, 100 Specifications and auto switch information not provided below are
PFA712H 55 160 40 92 67 55 Rc 1, NPT 1, G 1 36 M5 x 0.8 8 OUT1 80mA Load Black 65 180 45 104 79 65 Rc 1 1/2, NPT 1 1/2, G 1 1/2 46 M6 x 1 9 ON OFF 75 220 55 114 89 75 Rc 2, NPT 2, G 2 56 M6 x 1 9 50msec PFA7H-(-M) 68 69 Analog output 1 to 5VDC 4 to 20mADC 5 20 Analog output [mA] Analog output [V] 1 4 Min. measured flow rate value Max. measured flow rate value Real-time flow rate [l/min]
2$1@2@4!7 With rubber bumper: CNGBN $6 $0 $7 #2 #1 #3 #6 #9 y #0 $0 @6 q @3 !0 !1 u #4 $5 !5 !4 @5 #5 CL Long stroke CL1 @8@9 @6$3o$2!3r!6i!9@1!
(mounted on different sides) 2 pcs. (mounted on same side) 1 pc. 2 pcs. (mounted on different sides) 2 pcs. (mounted on same side) 1 pc.
KKA9S-10M -12M -14M KKA3S-01M-1 -02M-1 -03M-1 KKA4S-02M-1 -03M-1 -04M-1 KKA6S-03M-1 -04M-1 -06M-1 R 1/8 R 1/4 R 3/8 R 1/4 R 3/8 R 1/2 R 3/8 R 1/2 R 3/4 R 1/2 R 3/4 R 1 R 3/4 R 1 R 1 1/4 R 1 R 1 1/4 R 1 1/2 R 1/8 R 1/4 R 3/8 R 1/4 R 3/8 R 1/2 R 3/8 R 1/2 R 3/4 R 1/2 R 3/4 R 1 R 3/4 R 1 R 1 1/4 R 1 R 1 1/4 R 1 1/2 1/8 1/8 1/4 1/4 With check valve 1/2 1/2 3/4 3/4 Without check valve 1 1 1 1
Bar length symbol 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 ZVB IZS40-E3 IZS40-E4 IZS40-E5 2 1 1 1 2 2 2 1 2 Standard model no.
1 !0 o e !1 e w w y y q q !2 !2 IN OUT IN OUT u r t i u r t i Component Parts Material AWG20K AWG30K AWG40K Note No. Description Body 1 ZDC ADC Platinum silver Bonnet 2 PBT Black Handle 3 POM Black Replacement Parts Part no. AWG20K No.
LVH LVD Table (1) Port/Orifice Size Valve (Port size) Orifice size (No.) LVQ 1 (1.5 mm) 2 (2.2 mm) 3 (3 mm) 4 (4 mm) VXA31 VXA32 LQ 01 ( ) 1 8 02 ( ) 1 4 02 ( ) 1 4 03 ( ) 3 8 LVN TI/ TIL Ordering example (Example) Series VXA31, Orifice size 1.5 mm, Rc 1/8 (Part no.) VXA3114-01 PA PAX PB 17-3-103
30 2 x 3.5 depth 1 4 x M4 x 0.7 depth 6 Variable angle (Female thread mounting) 90 19.5 1.9 (Power supply switch) 6 (With connector plugged in) 37.5 R41 (84) 25 R76 27 Fan Type Ionizer IZF10/IZF10R Series Dimensions IZF21/31 IZF10/IZF10R Technical Data Power supply cable IZF10-CP L 45 2 36 2 Terminal semi-stripped 3 1 7 1 4.3 4 1 Wiring/IZF10 Pin no.
Pressure source fluctuation, small hysteresis or the response time is too short. (1) Check the pressure setting. (1) Check the set pressure (hysteresis) (2) Reset the function settings. (2) Check the response time The operation is unstable.
Name Lead wire colour Function 1 DC(+) Brown 12 to 24 VDC 2 OUT2 White Switch output 2 3 DC(-) Blue 0 V 4 OUT1 Black Switch output 1 -16No.PS-OMW0002-C Wiring examples Setting of NPN open collector 2 outputs Setting of PNP open collector 2 outputs : Numbers in the figures show the connector pin layout. -17No.PS-OMW0002-C Outline of Settings [Measurement mode] Power is supplied The product
L/min Instantaneous flow 2 to 210 L/min Set flow rate range Accumulated flow 0 to 999,999,999 L Flow Instantaneous flow 1 L/min Minimum setting unit Accumulated flow 1 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse Accumulated value hold 2 Every 2 minutes or every 5 minutes.
Bar length (mm) IZS31-E3 IZS31-E3 IZS31-E4 IZS31-E5 1 300 30 1 380 1 1 620 80 1 1 780 L 1 3 1100 3 1 1260 2 2 1500 Part no L 5 1 1900 IZS31-E3 IZS31-E4 IZS31-E5 200 4 2 2300 280 360 The model number requires the suffix -X14 to indicate that the body is to be shipped fitted with a security cover. IZS31 Standard part no.
/O.D. mm Symbol Symbol Symbol 01 02 03 04 N01 N02 N03 N04 07 09 11 13 06 08 10 12 07 09 11 13 6 8 10 12 1/4" 5/16" 3/8" 1/2" R, Rc1/8 R, Rc1/4 R, Rc3/8 R, Rc1/2 NPT1/8 NPT1/4 NPT3/8 NPT1/2 50 60 65 80 85 110 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Metric size The figures in ( ) indicate the internal diameter of the applicable hose.
ZB-OM00201-B Model Indication for Manifold (1) Number of stations 01 1 station 02 2 stations 12 12 stations (2) Pressure sensor/Vacuum pressure switch mountable Note 1) NIL Sensor/ switch non-mountable base S Sensor/ switch mountable base Note 1) Select S when the model with either the pressure sensor or the pressure switch for vacuum is selected for how-to-order for the single unit (8)
Value 7 6 5 4 3 2 1 0 Value 7 6 5 4 3 2 1 0 Output No. 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 1 0-7 All clear output Setting value 00 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 Output No. 15 14 13 12 11 10 9 8 15 14 13 12 11 10 9 8 2 8-15 All hold last state Setting value FF 1 1 1 1 1 1 1 1 00 0 0 0 0 0 0 0 0 Output No. 23 22 21 20 19 18 17 16 23 22 21 20 19 18 17 16 3 16-23 All force output Setting value
Contents 1 1 200 to 220 VAC 100 to 240 VAC 2 2 200 to 220 VAC 100 to 240 VAC PE 2 1 3 3 PE HRG HRS HRZ HRZD HRW HEC HEB HED Technical Data Related Products 2. Communication connector (RS-232C or RS-485) D-sub 9 pin (socket) Holding screw: M2.6 Signal contents 3 2 Pin No. RS-232C RS-485 5 4 1 1 Unused BUS+ 2 RD BUS 3 SD Unused 4 Unused Unused 5 SG SG 6-9 Unused Unused 9 8 7 6 3.
10 1 2466 LCD * -8No.PS-OMU0008CN-D ISE20C X M 2 3 ISE20C -0.100~1.000 MPa Y ZSE20C 0.0~-101.0 kPa K ZSE20CF -100.0~100.0 kPa T ISE20CH -0.100~2.000 MPa 24 X NPN2 A1 A Y PNP2 A3 C R NPN2+1 B T PNP2+1 E S NPN2+1 D + V PNP2+1 1: F + 4 2 M SI3 1 P psi2 2 3 kPaMpa (2m ) W 2 R1/4 C01 Rc1/8 N02 NPT1/4 A2 URJ1/4 L F02 G1/4 B2 TSJ1/4 2 2 () L() A A1 ZS-46-A1 C A3 ZS-46-E
SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70