L1 D L2 L3 L4 L5 L6 L8 Model Port size AS2000E-01 4.5 16 57 61.5 15.5 10 17 30 5 40 1/8 AS2000E-02 4.5 20 59 63.5 17 12 23 30 5 40 1/4 AS3000E-02, 03 5.5 26 69 76 20.6 13.25 25 45.5 5.25 56 1/4, 3/8 AS4000E 2-1/4 to 1/2 72 (Max. 80) Effective thread depth 6 15-9-42
Pressure set1ing range -1 OOkPa . l DOkPa {1.D2kgf/cm2 } 0. 1 MPa1MPa {1 O.2kgf/cm2} (MPa. kPa, kgf/cm2, mmHg. bar, PSI) mmHg, kPa, PSI MPa, PSI Unit indicalions kgf/cm:i, bar kgf/cm2, bar -Variety of switch output modes MPa:O.01. PSI:1 Min. dISplay dilferenllal kgf/cm2 :O.02. bar:O.D2 kgf/cm2:O. 1, bar:O.1 mmHg:l 0. kPa:2.
Meter-out: Gray Meter-in: Light blue 23 3.2 Note 2) 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" ASR ASQ 04 4 06 6 08 8 10 10 12 12 16 16 Thread type Nil R N NPT Note 1) For selecting applicable tubing O.D., refer to the Model on page 554. Note 2) Use 1/8" tube. Port size 01 1/8 02 1/4 03 3/8 04 1/2 Made to Order (For details, refer to page 562.)
Note1) Metric size Inch size 02 2 23 3.2 Note 2) 01 1/8" 03 5/32" 07 1/4" 04 4 06 6 Note 1) For selecting applicable tubing O.D., refer to the Model on page 667. The color of the release button is white (metric, inch). Note 2) Use 1/8" tube.
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1
200 S AS 01 X785 Pilot port Port size Body size Thread type Seal method 2 1/8, 1/4 3 3/8 4 1/2 Nil R, Rc G G Nil Without sealant (for G) S With sealant (for R) Cylinder side 01 1/8 02 1/4 03 3/8 04 1/2 * R thread type: With sealant G thread type: Without sealant Valve side Cylinder side 04 F 10 S AS4201 X785 Pilot port Thread type Seal method Nil R, Rc G G Nil Without sealant (for G) S With
1 8 VEX How to Order SRH ARM 1000 A1 5 01 G SRP Semi-standard Regulator for manifold Nil 1 0.7 MPa setting (Standard) 0.2 MPa setting SRF Number of stations Note 1) Pressure gauge for 1.0 MPa is used.
+ 30 (n 2) (n = 2, 4, 6, 8) Note 1) 80 + 30 (n 2) (n = 2, 4, 6, 8) Note 1) 85 + 30 (n 2) (n = 2, 4, 6, 8) Note 1) n (Same surface) 90 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 95 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 100 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 105 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 110 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 1 60 65 75 80 85 2 (Different surfaces) 70 75 80
Pressure 50 45 40 3/8" 45 40 35 40 35 Pressure Drop (psid) 30 1" 3/4" 35 Torque (in-lbs) 30 25 30 1" 1/2" 25 1/4" 1/4" RPM 25 20 1/2" 3/8" 20 3/4" 20 15 3/4" 15 15 1/2" 3/8" 10 1" 10 10 2" 1/4" 5 5 5 1-1/2" 0 0 0 0 2000 1000 3000 4000 5000 1000 0 2000 3000 4000 5000 0 10 20 30 40 50 60 70 80 90 Pressure (PSI) Pressure (PSI) Flow (USGPM) Quick Coupling Division 8145 Lewis Road Minneapolis
Parameter Definition Item Content Default Parameter setting setting range 2/2/2/2 byte I/O size of port 1 to 4: 2 byte/2 byte for each 4/4/4/4 byte I/O size of port 1 to 4: 4 byte/4 byte for each 8/8/8/8 byte I/O size of port 1 to 4: 8 byte/8 byte for each I/O size of port 1 and 2: 16 byte/16 byte for each 16/16/2/2 byte I/O size of port 3 and 4: 2 byte/2 byte for each I/O size of port 1
2: Clear / PD Out invalid 4..5 Idle output (IO-Link) 0: Clear 1: Hold 2: Force ON 6..7 Idle output (DO) 0: 2 / 2 / 2 / 2 1: 4 / 4 / 4 / 4 2: 8 / 8 / 8 / 8 3: 16 / 16 / 2 / 2 4: 32 / 2 / 2 / 2 Process data mapping Port1/Port2/Port3/Port4 (Input and Output) 4 0..7 0 L+ control Port 1 0: L+ ON, 1: L+ OFF 1 L+ control Port 2 0: L+ ON, 1: L+ OFF 5 2 L+ control Port 3 0: L+ ON, 1: L+ OFF 3
KKA9S-10M -12M -14M KKA3S-01M-1 -02M-1 -03M-1 KKA4S-02M-1 -03M-1 -04M-1 KKA6S-03M-1 -04M-1 -06M-1 R 1/8 R 1/4 R 3/8 R 1/4 R 3/8 R 1/2 R 3/8 R 1/2 R 3/4 R 1/2 R 3/4 R 1 R 3/4 R 1 R 1 1/4 R 1 R 1 1/4 R 1 1/2 R 1/8 R 1/4 R 3/8 R 1/4 R 3/8 R 1/2 R 3/8 R 1/2 R 3/4 R 1/2 R 3/4 R 1 R 3/4 R 1 R 1 1/4 R 1 R 1 1/4 R 1 1/2 1/8 1/8 1/4 1/4 With check valve 1/2 1/2 3/4 3/4 1 1 Without check valve 1 1
(Pitch) P = 10 12.8 34.3 23.6 32.1 15.4 15.6 3/5 3/5 3/5 2 2 2 2 2 2 2 30.6 46.2 54.5 1 1 1 58.2 4 4 4 4 4 4 4 D D D M5 x 0.8 [4(A), 2(B) port] One-touch fitting [4(A), 2(B) port] Applicable tubing O.D: 2, 1/8" 4, 5/32" 6, 1/4" One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D: 8, 5/16" One-touch fitting (PE: Pilot EXH port) Applicable tubing O.D: 4, 5/32" 20.5 6.2 One-touch fitting
VX3 Valve type Material VXA 0 1 2 N.C. N.O. Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 VN Symbol 01 02 01 02 02 03 03 04 04 06 10 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Body class Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.
LVN Valve type Material TL/TIL 0 1 2 N.C. N.O. Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Symbol 01 02 01 02 02 03 03 04 04 06 10 Body class LQ3 Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.
[mm] Connection thread Rc Model T (M) Weight [g] X (X) Y Nylon Urethane hole M 7 mm or less H1 H2 T Oval type Round type 4 1/8 KQ2E04-01G1 M12 x 1 14 14 24.4 10 7.7 10 13 13.3 5.6 4 3 21.2 1/4 KQ2E04-02G1 M12 x 1 17 14 29 14.6 7.7 10 13 13.3 5.6 4 3 30.9 4, 6 8 to 16 6 1/8 KQ2E06-01G1 M14 x 1 17 17 23.6 9.2 9.7 12 15 13.3 13.1 10.4 4.5 28.9 1/4 KQ2E06-02G1 M14 x 1 17 17 28.4 14 9.7 12 15
3(R) port 2-Rc 1/2 1(P) port 4-G 1/2 Conduit port VQC SMC SMC SMC SMC SMC SMC SMC SQ 95.5 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 77.5 90 72 VQ0 13 55.5 42.7 43.5 20.5 VQ4 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 33.5 11.5 15.7 12 2-Rc 1/8 (Pilot exhaust port) VQ5 (6.5) 21.5 2-Rc 1/8 (External pilot port) 27 2n-Rc 1/4, 3/8, C8, C10, C12 <4(A), 2(B) port> Rc 1/4: 1/4" Female thread Rc 3/8: 3/8" Female thread
fluid and facility water piping . 4-1 4.1.4 Operating signal from your system . 4-1 4.1.5 Check emergency off [EMO] switch . 4-1 4.2 Opening of Facility water Valve . 4-1 4.3 Supply of Circulating Fluid . 4-2 4.3.1 Preparation of circulating fluid . 4-2 4.3.2 Supply of circulating fluid . 4-3 4.4 Requirement for System Startup . 4-4 4.4.1 Turning ON power. 4-4 4.4.2 Circulating fluid temperature
NPT 1/8 CS1 32 NPT 1/8 40 NPT 1/4 C76 50 NPT 1/4 NPT 1/4 63 C85 80 NPT 3/8 NPT 3/8 100 NPT 1/2 NPT 1/2 C95 Series RSQ Series CY Series MGQ Series MY1 CP95 Bore size (mm) Bore size (mm) Bore size (mm) Bore size (mm) Port size Port size Port size Port size NCM 20 20 20 25 NPT 1/8 NCA NPT 1/8 25 32 25 32 NPT 1/8 NPT 1/8 32 40 32 40 NPT 1/4 DNPT 1/4 40 50 40 50 NPT 3/8 NPT 1/4 50 50 63 NPT 1
ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM