Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: Voltage, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): -5~50, Operating Humidity
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: -, Calibration Certificate: -
Pressure Range: -100.0 to 100kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: w/Certificate
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: w/Certificate
Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: w/Certificate
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/Flow
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
* 16.2 P.72 RESET BDC24V E 16.1 5 OUT0~3 IO (OUT0OUT3) SVRESETON IO ALARM OUT0 (OUT1) OUT2 OUT3 B ON OFF ON OFF OFF C ON OFF OFF ON OFF D ON OFF OFF OFF ON E ON OFF OFF OFF OFF IO SVRE SETON B RESET C RESET D OFF RESET,SVON E OFF OFF D 1 D SVREOFF (OFF) 2 RESET() SVON SVREON(ON) 71 - 16.2 code <> 12 12 0 1-048 B RESET <> <> -+ W 1W 2 W 12 0 1-049 PARA B RESET <>
When PA exceeds the specified pressure, the force that pushes up the valve e becomes smaller than the force that pushed down the spool w.
When PA exceeds the specified pressure, the force that pushes up the valve e becomes smaller than the force that pushed down the spool w.