K J E Size variations Standard strokes Model Auto switch 20 30 40 50 100 60 70 80 90 C(D)U20 20 to 32 Direct mounting type auto switch C(D)U25 C(D)U32 Features 2 Free-Mounting Cylinder with Air Cushion Series CU 20, 25, 32 How to Order CU 32 32 50 50 A A F9BW With auto switch CDU Without auto switch Number of auto switches With auto switch (built-in magnet) 2 pcs. Nil S 1 pc.
If an instantaneous flow of 10 L/min lasts for 5 minutes, the accumulated flow will be 10 x 5=50 L. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.It is possible to calculate the total accumulated flow by counting the pulses.
N.O. 1/4 to 2 32 A to 50 A 10 to 50 N.C. N.O. 1/4 to 1 32 A to 50 A 10 to 50 Series VXA21/22, VXA31/32 Series VNC For Air, Vacuum, Water, Oil Air Operated 2/3 Port Valve Cutting Oil, Coolant for Machine Tool, etc. Coolant Valve Valve type Port size Body Seal Cast iron NBR N.C. N.O. C.O. Valve type Model Port size Body Seal N.C.
Electric specifications of the power supply HEC006 AC200-220V, 50/60Hz 5A Single phase 2-wire type + GND (PE) line HEC012 AC200-220V, 50/60Hz 10A Single phase 2-wire type + GND (PE) line Do not bend, pull or bind the power supply cable with a strong force.
A B C A B A B A B A B 15A 20A 25A Note 1) For each piping diameter for each body size, the second and later numbers or symbols indicate reducing.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
[Horizontal and lateral mounting] A B SOL.3 W RE A B A magnetic field of 14.5 mT is equivalent to a position that has about 18 cm radius from a welded part using about 15,000 amperes of welding amperage. When using it in a stronger magnetic field, cover the sensor with magnetic and shield it.
MY-SA 2-G F E 2-H C D A B Side support B MY-SB 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.
Note 8 Pad ZP3E-mmm Flat/Bellows type with groove r 9 Plate ZHP1-PLm-A 10 Holder ZM u e 11 Plug TB00148 Included for metric size ZL TB00055 Included for inch size q w 12 One-touch fitting KJHm-C2 ZH 13 Ejector assembly ZK2-EJmW-A A A 14 Silencer assembly ZHP1-SA1-A ZH 15 Lock screw CA00284 Included ZH -X267 3 pieces are included in one product. (The part numbers are for 1 piece.) !
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or Caution moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death Warning or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or Danger serious injury. Warning 1.
Adjustment bolt (A) Adjustment bolt (B) For 90 rotation Single vane (S): 80 to 100 adjustable Double vane (D): 85 to 95 adjustable A B 180 Adjustment range of adjustment bolt (A) Adjustment range of adjustment bolt (B) 10 10 22.5 Size Allowable radial load (N) Allowable thrust load (N) Allowable moment (Nm) 1 10 15 20 0.3 A B Positioning pin hole 3 15 30 40 0.7 7 30 60 50 0.9 Adjustment bolt
SYJA 2(A) 2(A) Standard VZA (P)1 3(R) (P)1 3(R) i VFA 2(A) 2(A) 2(A) 3(R) VFRA o For vacuum (P)1 3(R) (P)1 3(R) VPA4 SYJA X VZA 1(P) VTA For vacuum u y t r e w q VGA VPA VPA VPA3 i 2(A) 3(R) o X Component Parts No.
B-1 2 L A A-1 1 B B-2 6 1 1.5m B A-2 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 S 9 B A-6 8 3 14.2 2 1 (8) 14 18 B1 A1 17.7 5 6 2 1 A6 B6 15 16 11 30.7 112 [820m] A B-1 2 A A-1 1 L B B-2 6 8 8m B A-2 5 COM-A/COM B-3 3 A 10m COM-B/ A-3 4 B 15m Shield C 20m Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6
Model determination 61 Series REBR Model Selection 2 Design Parameters 1 Selection Method A: Distance from cylinder shaft center Allowable driving capacity> REBR25 REBR32 REBR15 500 400 300 200 300 200 Allowable driving force Fn (N) Load weight W (kg) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 40 50 20 30 40 50 30 20 20 Usable range 10 10 10 Usable
(mm) Electrical entry P Port size B C D E F H K L M N A Model Grommet: G Conduit: C Conduit terminal: T Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101
60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 240 VAC, Hz Other (Without connector) 50 60 50 60 50 60 4 5 6 7 50 60 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 9 Option Port size M5 x 0.8 Rc 1/8 (A port) M5 01 Body ported (Single
L32 pin clamp cylinder available O Compact design makes it applicable to a broad range of workpieces. OContributes to a lightweight jig.
B A B A B A B A B A B A B HS HS HS HS HS 20 20.6 9 14.6 8.5 14.1 14 10.5 16.1 12.5 18.1 11.9 17.5 19.6 15 24.5 27.3 62 69.7 27 25 20.6 9 14.6 8.5 14.1 14 19.6 10.5 16.1 12.5 18.1 11.9 17.5 15 27 29.8 64.5 72.2 29.5 32 22.6 8.9 16.6 8.4 16.1 13.9 10.4 18.1 12.4 11.8 19.5 21.6 20.1 14.9 30.5 33.3 68 75.7 33 40 27.7 13.9 21.7 13.4 21.2 18.9 26.7 15.4 23.2 17.4 25.2 16.8 24.6 19.9 35 37.8 72.5
D. 9 to 11:P368010-27 At accessory H: (with external scale plate) 100 44 46 IP8100-01 (With terminal box) OUT2.Rc1/4 110 38 192 251 110 40 35 58 218 OUT1.Rc1/4 SUP.Rc1/4 23.5 43 23.5 38 39 11 9 39 OUT2 MPa 0% 50 42 20 162 117 25% MPa 65 A 15 122 ELECTORO PNEUMATIC IP8100 P O S I T I O N E R DA 50% 22.5 75% 100% 125 View A 12 168 8 2 x M8 x 1.25 depth12 Female thread for side mounting 2 x
This could cause a malfunction. 5. Vibration When vibrations are applied on an impacting material, implement a secure guide on the impacting material. D-X 891 RJ Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 3 to 12 for Common Precautions. Mounting Warning Caution 1.