.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZL ZY ZQ ZF ZP ZCU AMJ Misc.
When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Base mounted (4 port) VR (Manifold use only) SYJA3 30 2 VH VHS Base mounted (5 port) SYJA3 40 2 Port size Type of actuation Nil Without sub-plate 4 3 2 position double 2 position single 2 1 M5 port with sub-plate M5 3 position closed center JIS Symbol
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F Foot bracket Mounting bracket are supplied, but unattached.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Functions Error function Display calibration function Take the following corrective solutions when error occurs.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4. Selection of response time 5. Setting Auto/Manual SET SET SET Press the SET button. Press the SET button. Press the SET button to complete the setting.
900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 AU Flow rate (/min (ANR)) Flow rate (/min (ANR)) AF AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ARX21-01 ARX21-02 0.35 0.35 IR 0.30 0.30 Outlet pressure (MPa) Outlet pressure (MPa) VEX 0.25 0.25 0.20 0.20
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 8 Rc 3 position exhaust center 1 4 1 8 Rc 0.86 VR 1 8 Rc Note) The table shows the valve without sub-plate. With sub-plate: Add 0.24 kg VH Specifications Large flow capacity.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VR Model VH Flow characteristics Pilot port size Pilot port piping location b Cv b C [dm3/(sbar)] 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) C [dm3/(sbar)] Cv Function Port size Valve model VHS VZA2121-M5 VZA2221-M5 VZA2321-M5 VZA2421-M5 VZA2141-1-01 VZA2141
AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IR VEX Maintenance and Other Warning AMR 1. Perform maintenance and inspection on a regular basis.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP Pads can be directly mounted. ISA2 Manifolding is possible.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 IF For details about certified products conforming to international standards, visit us at www.smcworld.com. Data Push-button calibration allows for precise and simple set up.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Selection Selection Selection Selection Selection Warning 1. Check the specifications.
When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available. Please contact SMC. 3) 14 to 194F (10 to 90C) for Vespel seat.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Due to its small size, the sensor can be installed close to a pad.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 IF Data Can be integrated with ZX or ZR ejector system.
How to Order Port Number e r KT10 R C 4P 4 1 0 0 Installation option Delivery pressure Code Installation Panel installation Delivery pressure Code 5 to 500 psig (0.034 to 3.4 MPa) 5 to 800 psig (0.034 to 5.5 MPa) 10 to 1500 psig (0.07 to 10.3 MPa) 15 to 2500 psig (0.1 to 17.2 MPa) 25 to 4000 psig (0.17 to 27.6 MPa) 50 to 6000 psig (0.34 to 41.4 MPa) 100 to 10 psig (0.7 to 69 MPa) 1) No code
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
The CNA2 series cylinder with lockĀ isĀ suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated
Magnet: None, Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 800mm, Bellows/Cushion: Cushion Both Sides