JS20, 32, 40, 63 Center of sphere M M U U D J F B E G P A R H (mm) Max. thread depth P Center of sphere R Allowable eccentricity U Max. operating tension and compression force (N) Weight (kg) M A B C D E F G H J Model JS10-4-070 JS16-5-080 8.5 0.5 17 0.01 14.4 M4 x 0.7 9.5 12 4 7 4.7 80 4 1.5 26 12 0.5 23 19 0.02 M5 x 0.8 13.5 16 6 10 5.8 210 5 2 34.5 JS20-8-125 JS32-10-125 15.5 0.5 29.9
Black 6 A A-5 Orange 9 B B-6 Nil Robotic type B A-6 Black 8 3 (d) cable Signal name Terminal number S Standard cable Red 4 Lock (+) B-1 Black 5 Lock (-) A-1 Brown 1 Sensor (+) B-3 Sensor (-) A-3 Blue 2 Actuator side Controller side (8) (14.2) (a) (b) A1 B 2 1 (17.7) 1 (14) (18) A6 B6 5 6 (10.2) 2 1 B1 A1 B3 A3 (d) (5.7) 15 16 (c) L (11) (30.7) 10.6 Actuator cable [For sensor/ with lock (
B B-6 Nil Robotic type B A-6 Black 8 (d) 3 cable Signal name Terminal number S Standard cable Red 4 Lock (+) B-1 Black 5 Lock (-) A-1 Sensor (+) B-3 Brown 1 Sensor (-) A-3 Blue 2 Actuator side Controller side (8) (a) (b) (14.2) B1 A1 2 1 (17.7) (14) (18) B6 5 6 A6 (10.2) B1 A1 B3 A3 (d) 2 1 (5.7) (c) 15 16 L (11) (30.7) 12.6 Actuator cable [For sensor/ with lock (8-20m)] (a) (b) Signal name
Adjustment bolt b CRA1 Adjustment bolt d CRQ2 q First adjust both rotation end positions. Apply pressure to ports A and C to adjust adjusting bolt b. Apply pressure to ports B and D to adjust adjusting bolt a. Lock the bolts with fixing nuts after adjustment. w Next, apply pressure to ports A to D to adjust the center position. Loosen the fixing nuts for adjusting bolts c and d.
D-A72/A7H D-A80H/A73C D-A80C/F7/J79 D-J79W/F7V D-J79C/F7W D-F7WV/F7BAL D-F7BAVL/F79F Auto switch model D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AVL D-A9 D-A9V D-A73 D-A80 D-A79W D-F7NTL D-P4DWL Bore size A B A B B A B A B A A A B B 32 40 50 63 36.5 26 30 40.5 27 37.5 27.5 38 32.5 43 24.5 35 42 30 34 46 31 43 31.5 43.5 36.5 48.5 28.5 40.5 27 39 43 32.5 36.5 47 33.5 44 34 44.5 39 49.5 31 41.5 29.5
Circuit Diagram : D-90Type Bore Dimension A j Dimension B Dimension C ;t)-k.
D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.
Next, IB is entered to find IA the moment of inertia for the rotation of shaft (A) as a + b 2 2 A = ( ) b a 2 B = m 12 No. of teeth = b 11-10-3 4 Technical Data 3: Theoretical Output 5.
Intermediate bracket A. Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. M5 tap M5 threads 4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (M5) of brackets.
AC-OMT0014-A PRODUCT NAME AIR COMBINATION MODEL/ Series AC10(A,B)-A AC20(A,B,C,D)-B AC25(B,C)-B AC30(A,B,C,D)-B AC40(A,B,C,D)-B AC50(A,B)-B AC55(B)-B AC60(A,B)-B Contents PAGE 1. PRECAUTION FOR SAFETY 18 2. APPLICATION 9 3. SPECIFICATIONS. . . 9 4. SERIESMAP AND COMBINATION OF EQUIPMENT. . . 10 5. HOW TO ORDER 1118 6. ATTACHMENTS / ACCESSORIESOPTIONSPART NUMBER 19 7.
D-M9V, D-M9WV D-M9A D-M9AV A B W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable
A port: n-Rc 1/8 Note for P1 Confirm internal pilot or common external pilot by checking whether P1 has a M5 screw or not. Internal pilot P1 has no M5 screw. Common external pilotP1 has an M5 screw.
Example) For 10-CQSXB25-47D, a 3mm spacer is installed inside a standard stroke 10-CQSXB25-50D cylinder.
AW20 (K) ro 40 (K) * When more than one sperrcalDn s.equ red, ndrcate n as.ending nlhe callhe. a phabetica order Port size Nole 1)The on y d ibrence lbm the standard specil lions s fre adjusting spring joflhe regutarol [do6 not resl(cl lhe sen ng ol02MPa ormore sYmbot Pgrt 1 0 20 40 Nole 2) Wlhout a valle tufclon M5 a 1/8 a a a a 3/8 a a 1i2 a 314 a Nole 3) For M5 and NPT thread rype Accessories
Proper Auto Switch Mounting Position (Detection at stroke end) MX A B MTS MY MY3A D-A9, D-A9V (mm) D-F9W, D-F9(W)V (mm) D-M9, D-M9V (mm) CY A B Operating range Bore size 16 25 40 63 A B Operating range Bore size 16 25 40 63 B Operating range Bore size 16 25 40 63 A 088.5 084.5 26.5 084.5 22.0 26.5 2 06.5 3.0 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080
C D A B (mm) D-A9, D-A9V (mm) D-F9, D-F9V (mm) D-F9W, D-F9WV A A A B B B Bore size 16 25 32 Operating range Bore size 16 25 40 Operating range Bore size 16 25 40 Operating range 54 106 58 102 57 103 54 156 58 152 57 153 11 8.5 8.5 85 245 89 241 88 242 (mm) (mm) (mm) C C C D D D Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range 27 133
/B64 D-B59W D-G5BAL D-G59F D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C Auto switch model D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C D-H7C D-G5NTL D-G5W D-K59W D-G5BAL D-G5 D-K59 D-G5NTL D-H7W D-H7BAL D-H7 D-H7C/H7NF D-C7/C80 D-C73C D-C80C D-C73C D-C80C D-B5/B64 D-G59F D-B59W Applicable bore (mm) Hs Hs Hs A A A A A B B B B B B 16 (24) A 21.5 (29.5) 20.5 (28.5) 15.5 (22.5) 17.5 (25.5) 19.5 (27.5)
Switch operating position (ON) Hysteresis Switch reset position (OFF) Unit: mm Auto switch model Air gripper D-Y7 W N B D-Y59A B D-Y69A B D-Y7 WV N B D-Y7BA 0.8 0.6 0.7 0.5 MHL2-10Dl Note)Use a watchmakers screwdriver with a grip diameter of 5 to 6mm to tighten the auto switch set screw. Use a tightening torque of 0.05 to 0.1 Nm.
, are Nil, A, B, D, E, Z. 3 Available for air and water. 270 IN OUT C 3 A 3 A 6 D 1 Available for the VXZ A to 2 .