Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: Y (w/o Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: T (w/o Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
This is a legacy product, and replaced byISE20A-T-01-J ISE30/ISE30A PRESSURE SWITCH. SWITCH. INSTRUMENTATION. ISE30 1/8 INCH PT VERSION. .22875 lb. CA.
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
2 (A) ] 0.5 [2 (A) 3 (R) ] bar) ) b 0.2 [1 (P) 2 (A) ] 0.15 [2 (A) 3 (R) ] Rc, NPT, G1/8 ON Delay 480g (*) 4 4 V R 2 1 1 0 01 01 Rc 1/8 N01 NPT 1/8 F01 F01 2 G 1/8 9 5 VR 1 ON Delay 0.560 () () 1 ON OFF 6 (1) 2 0.5MPa 2 10 (2) VR2110 3 )0.25MPa A 60sec (), (S) 0.8MPa 40sec B (3) (MPa) 3 OFF 1)4 1) OUT 0.7 0.6 VM1 VM1 () 0.5 0.4 0.3 0.2 ,0.6MPa VM2 VM2 0.1 ,0.3MPa 2
Ref er t o t he SM C w ebsi t e ( U RL ht t p: //w w w . sm cw orl d. com ) f or m ore i nf orm at i on about t roubl eshoot i ng. Thi s operat i on m anual ref ers t o general di gi t al i nput t ype ( m odel : X93) and i s part i al l y appl i cabl e t o anot her speci al m odel s.
Drain Discharge Q B ZM Drain guide (-J) ZH ZU Maintenance space 40 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com R ZL P Rc 1/8 Drain 1/4 female thread without valve function ZY Hexagon width across flats 24 ZQ AMJ5000 L A F ZF Bracket (Option) G K M ZP D J C E
Pressure Switch: For Air ISE70/71 Series How to Order p. 6 Options/Part Nos. p. 6 Specifications p. 7 Set Pressure Range and Rated Pressure Range p. 10 Internal Circuits and Wiring Examples p. 10 Dimensions p. 11 Function Details p. 12 Safety Instructions Back cover 5 RoHS 3-Screen Display High-Precision Digital Pressure Switch: For Air ISE70/71 Series How to Order ISE70 02 M L2 Pressure