(Non-locking) Manual override 69.4 (30.5) 24 13.5 2-6.5 (For mounting) (X port) (M5 x 0.8) (R port) Rc 1/4 101.6 26.7 (17.5) 3(R) 1(P) 3(R) 1(P) 3(R) 1(P) 3(R) 27 50 V100 1(P) MAX.10 D: 112.8 26.7 Y: 112.3 101.6 102.4 MAX.10 112.8 (P port) Rc 1/4 SY SYJ 300 (Pitch) Pg9 Pg9 85.6 95.6 27.5 28 (Lead wire length) 95.1 105.1 Y: 97.6 114.6 L1 L2 7.5 90.1 100.1 D: 95.6 112.6 Applicable lead wire
For vacuum equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www. smcworld.com Nozzle diameter Port size 05 0.5 mm 07 0.7 mm Nil 6 One-touch fitting 01 Rc1/8 female thread Symbol EXH Vacuum pressure reached S 90 kPa L 48 kPa Mounting P V Caution Specifications 1 .
AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10 20 50 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 40 30 5 10 20 10 0 5 0 5 20 10 10 0 10 Number of needle rotations Number of needle rotations Number
System: P (Vacuum Pump System, Single Unit), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L1 (L-type Plug Connector Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached
System: P (Vacuum Pump System, Single Unit), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit
System: P (Vacuum Pump System, Single Unit), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit
System: P (Vacuum Pump System, Single Unit), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L1 (L-type Plug Connector Lead Wire for Pressure Switch), Vacuum, V Port: 09 (Inch Size, ø5/16" One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting
NOTE [ on] Display ON [F80] [ dSP] Display OFF mode [F81] [P in] Security code [oFF] Not used The direct current power supply used should be UL approved as follows. Circuit (class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. The product is a UL approved product only if it has a mark on the body.
D-P3WA 56mm Nm D-M9(V) D-M9W(V) D-M9A(V) D-P3DWA 0.050.15 -12- (mm) L1 L2 L3 L4 L5 L6 16 5 MHM-16D 1 1 1 1 MHM-25D 36 34 MHM-32D 50 24 MHM-50D 23 25 80 41 / 3 NPN 3 PNP PLC PLC 2 2 PLC PLC PLC PLC -13- AND(),OR() *50ms 3 NPN OR 3 NPN AND 1 1 1 2 2 2 3 PNP AND 3 PNP OR 1 1 1 2 2 2 2 AND 2 OR 2 AND ON , 2 ON 20V 2 OR OFF OFF 1 1 ON 2 2 ON =-2 OFF =2 =1mA2 3k =6V 3k
) NPT Nil F N Voltage Manual override/Classification C F H J P V Y Z 9 1 2 3 4 5 6 7 8 A B 115 VAC, 50/60 Hz 32 VAC, 50/60 Hz 42 VAC, 50/60 Hz 230 VAC, 50/60 Hz 100 VDC 6 VDC 48 VDC 110 VDC Other voltages 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz 48 VAC, 50/60 Hz 12 VAC, 50/60 Hz 24 VAC, 50/60 Hz Electrical entry Non-locking
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
-23 AS221F-01-01 1/8" 20.4 3.2 9.3 20.4 16 27.5 27.5 16 9.3 12.7 12.7 AS221F-01-04 AS221F-01-03 5/32" 4 20.4 27.5 27.5 20.4 17 9.3 9.3 14.2 13.4 13.4 17 12 12 AS221F-01-06 AS221F-01-05 35.2 30.2 32.1 13.5 27.1 3/16" 6 23.1 16.5 30.2 35.2 30.2 32.1 27.1 27.5 20.4 14.2 1/8 17 11.6 1/8 11.4 (12.7) (12.7) AS221F-01-08 AS221F-01-07 1/4" 8 23.9 18.5 32.4 25.3 15.2 18.5 13.2 31 19 19 AS221F-01-
: (800) 258-9200-www.stevenengineering.com KA (manual unlocking unit) Dust cover NH1 M(D)LUB25,32 (Extension locking) K H2 P ZZ1 + Stroke GB GA Unlocks when pressurized BP unlocking port Front cylinder port GC D GW GY NH (manual unlocking unit) Dust cover P Rear cylinder port NS + Stroke NG NF NJ NJ NI Width across flats KA MM Width across flats B1 EY EY NY C H1 AL 4-ND through 4-ET B A NB
GC1 MM1 KA (manual unlocking unit) Dust cover NH1 M(D)LUB25,32 (Extension locking) K H2 P ZZ1 + Stroke GB GA Unlocks when pressurized BP unlocking port Front cylinder port GC D GW GY NH (manual unlocking unit) Dust cover P Rear cylinder port NS + Stroke NG NF NJ NJ NI Width across flats KA MM Width across flats B1 EY EY NY C H1 AL 4-ND through 4-ET B A NB NA K 2 x 4-NC counter bore Prepared
VH*-OMX0068-A PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-R,Z)-D VHS30-(F,N)02~(F,N)03(-R,Z)-D VHS40-(F,N)02~(F,N)04(-R,Z)-D Contents Page 1. Safety Instructions 1~5 2. Application 6 3. Specifications 6 4. How to Order 7~8 5. Construction / Parts List 9 6.
Stations: 10 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: J (Vacuum Break Flow Adjusting Needle, Round Lock Nut), 1st Nominal Nozzle Size: 1 (ø0.7), 1st