cable (26P) without cable Flat ribbon cable (26P) with 1.5 m cable Flat ribbon cable (26P) with 3.0 m cable Flat ribbon cable (26P) with 5.0 m cable 25 pins IP40 compliant IP67 compliant 1 to 12 stations (24) FD0 FD1 FD2 FD3 D-sub connector (25P) without cable D-sub connector (25P) with 1.5 m cable D-sub connector (25P) with 3.0 m cable D-sub connector (25P) with 5.0 m cable 1 to 12 stations
D !"# Coil insulation type # 9% ,* /) 3 ? $% % 33 1 ,) % % 1 ) ,, ) /) H B 7 !"# ! , & Ordering example VX021-001GB-01 !"# $ % & VX021-002DBT-04 ' ( !
D !"# Coil insulation type # 9% ,* /) 3 ? $% % 33 1 ,) % % 1 ) ,, ) /) H B 7 !"# ! , & Ordering example VX021-001GB-01 !"# $ % & VX021-002DBT-04 ' ( !
Ground wire (1.5 m)/Accessories IZH-A-01 High-voltage measuring handle/Option IZH-C-01 Soft case/Accessories IZH-B-01 High-voltage measuring handle Ground wire Soft case Note) Be sure to use a high-voltage measuring handle in situations such as during high-voltage measurement when there is a possibility of personnel coming in contact with electricity.
1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4
D-B54, B64, and B59W cannot be mounted for bore size 044 and 056. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN For details about auto switches with pre-wired connector, refer to Best Pneumatics catalog. D-A9, M9, M9W are shipped together.
It cannot be used if connected in the opposite direction. 4.6-24 Series AME Dimensions: AME150 to AME350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4, 3/8
Option Manifold Plug-in unit 1 Option None Symbol Nil Stations 10 Clean series 2 B Note 2) D D0 D Note 5) K Note 3) N R Note 4) 200/220 VAC models (F/L kit only) With back pressure check valve DIN rail mounting With DIN rail bracket (Without DIN rail) With ejector unit Special wiring spec.
Option Manifold Plug-in unit 1 Option None Symbol Nil Stations 10 Clean series 2 B Note 2) D D0 D Note 5) K Note 3) N R Note 4) 200/220 VAC models (F/L kit only) With back pressure check valve DIN rail mounting With DIN rail bracket (Without DIN rail) With ejector unit Special wiring spec.
An example of when the SI unit station number is set to 01 is shown below.
D: Contents are added. [June 2017] E: Contents revised in several places.
L IZS41-CP 3000 +60 0 IZS41-CPZ 9850 +100 0 Shield Terminal semi-stripped 17.5 6.2 5 16.4 1 AB 60 47 L Cable Specifications No. of cable wire/Size 10 pcs./AWG20 (4 pcs.), AWG28 (6 pcs.) Nominal cross section 0.54 mm2 (4 pcs.) 0.09 mm2 (6 pcs.) Outside diameter 0.96 mm2 (4 pcs.) 0.38 mm2 (6 pcs.)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: w/o Lead Wire, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: -
Air consumption(Note 4) 1.0 or less [Measuring conditions: supply pressure 1.0 MPa, set pressure 0.2 MPa] [L/min(ANR)] Ambient temp. and Standard product: -5 to 60 Fluid temperature With digital pressure switch: 0 to 50 [OC] (No freezing) Port size 1/8 Pressure gauge port size 1/8 [2 ports] Weight [kg] Note 5)0.13 (Note 1) When there is no flow rate on the outlet side.
AL-OMQ0006-C PRODUCT NAME LUBRICATOR MODEL / Series / Product Number AL10-M5(-2,3,6,R,Z)-A AL20-(F,N)01(F,N)02(B)(-2,3,6,C,R,Z)-A AL30-(F,N)02(F,N)03(B)(-2,3,6,8,R,3W,Z)-A AL40-(F,N)02(F,N)04(B)(-2,3,6,8,R,3W,Z)-A AL40-(F,N)06(B)(-2,3,6,8,R,3W,Z)-A AL50-(F,N)06(F,N)10(B)(-2,3,6,8,R,3W,Z)-A AL60-(F,N)10(B)(-2,3,6,8,R,3W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2. APPLICATION 6 3.
H Clean One-touch fittings D MS Applicable tubing O.D.
XL-OMY0001 L // XLA-2 2 11 4 , 2.2 5 , , , , 33 7 4. 9 5 11 6. 13 7 14 1 XL-OMY0001 *1) *2) (ISO/IEC) (JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating