Displays exact the same pressure values for all channels. kPa MPa Auto identification function (page 14) Can automatically identify the pressure range of a connected P/A sensor. CH kPa MPa kPa MPa MPa kPa kPa MPa kPa MPa OUT1 OUT2 CH 1 2 3 4 P R E S S U R E Copy function (page 14) Each channel's information can be copied to another channel.
Table 1 Table 2 Output type ON YES Hysteresis mode For air OFF P-1 P-2 Display Instantaneous flow rate l/min Cumulative flow rate l Large flow rate "P" H H H (fixed hysteresis) = 3 digits CFM x 10-2 ft3 x 10-1 ON CFM = ft3/min Window comparator mode NO OFF P-1 P-2 For water Large flow rate OUT1 Output mode Display Instantaneous flow rate l/min Cumulative flow rate l ON YES OUT2 is the
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.03 s or less 0.03 s or less 0.05 s or less 0.05 s or less Response time Hysteresis 3% F .S. IR Repeatability 3% F .S. VEX Sensitivity 0.5% F .S.
EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 NPTF Passage symbol Port size (A) 4 (B) 2 Size 02 Size 01 Piping specifications Symbol Nil A01 A02 FG Without sub-plate 1 (P) 5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B) 2 Single Nil R Metal seal Double FJG Rubber seal 1 (P) 5 (R1
P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 e OR-1400-178P P: PTFE F: FKM OR-2670-178P r P: PTFE F: FKM Wave washer For VCS30, 40 When the loosened clip is pulled out in direction e using pinchers, etc., the coil can be removed and replaced in direction r.
8 x L counter bore J J A + Stroke M M Rod end male thread CHKDB20, 25 CHKDB32 to 100 Water resistant type S N g C B + Stroke h + Stroke A + Stroke Rod end male thread (mm) B C D E F G H J K L M P Q R A Bore size (mm) 20 51 43 8 12 10 M8 x 1.25 10 6 30 5.5 9.5 depth 5.4 43 1/8 16.5 6 25 53 45 8 14 12 M10 x 1.5 12 6 36 5.5 9.5 depth 5.4 49 1/8 17 8 32 61 51 10 18 14 M12 x 1.75 15 7 47 6.6
Fittings & Tubing Air Cylinders Rotary Actuators 2 x P (Rc, NPT, G) H2 Width across flats B2 2 x NN G Relief port M5 x 0.8 G H1 Width across flats B1 Standard port I Relief port 2 x Eh8 D MM AL A F K NA N N H S + Stroke F ZZ + Stroke (mm) ZZ S P N I E D A 12.5 11 10 10 13 F Bore size Stroke range AL K MM NA NN G H2 41 32 32 26 B2 H H1 22 17 17 13 B1 0 6 6 5 8 8 8 50 45 45 41 200 to 1000 150
Compact 35mm Light weight 120g 50mm 66mm 270g 700g Pressure gauge can be mounted from the front or rear Rear pressure gauge mounting Standard Back Pressure gauge VAC SET SMC P (Vacuum pump side) (Pad side) K U C S O H L VAC SET L H O S C Pressure gauge Panel mounting capability is standard U K P SMC (Vacuum pump side) (Pad side) Front Applications Lifting of work pieces Leak tester Pressure
Power consumption P: 1000 [W] Q = P = 1000 [W] Cooling capacity = Considering a safety factor of 20%, 1000 [W] x 1.2 = 1200 [W] V: Power supply voltage HRSH 090 P HRSH Power consumption HRSE HRSE e Derive the heat generation amount from the output. Output (shaft power etc.) W: 800 [W] w Derive the heat generation amount from the power supply output.
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
Axial piping available (6, 10) Compact Type Dual-Rod Cylinder Series CXSJ 6, 10, 15, 20, 25, 32 How to Order Piping Standard piping (6 to 32) Axial piping (6, 10) Nil Nil TN TF Standard piping Axial piping Port thread type Nil Port position M thread Rc1/8 NPT1/8 G1/8 6 to 25 P Port position 32 CXS P 6 M 50 F9BW J S Number of auto switches Compact type Nil S n 2 1 n M L Bearing type Slide
Note 2) When changing the port location, please order a new port plug: MXH-P (2 pcs.)
Contact P/A when the AC welding current exceeds 16,000 A.
m/s Piston Speed m/s 19 4-3 Selection Example .
Printed in Japan. 1st printing April, 2003 D-DN P-120 (DN) Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.
Vertical collision (Upward) Vertical collision (Downward) Horizontal collision ML2B25 Horizontal collision: P = 0.5 MPa CEP1 2000 1500 m m s s Stroke adjusting unit Type of impact Piston speed (mm/s) CE1 s 1000 Air cushion m 500 400 300 CE2 1 m2 2 Kinetic energy E1 ML2B ML2B
Normal operation Value clear Initial setting P.14 Adjust the zero point of atmospheric pressure. Detects and displays pressure and operates switch. Set "Output mode", "Response time" and "Auto/ Manual mode." Auto preset P.14 P.16 The pressure set point is calibrated automatically at the time of adsorption or primary pressure confirmation.
SMC 50 35 5 SMC 6 28 (R) P P K U K C S U O C H L S O H L 38 AV AU Panel cut Panel thickness: Max. 4 Panel cut Panel thickness: Max. 3 34 AF 40 15.4 x 5.4 AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IR 8 x 6.5 79 13 45.5 VEX Atmosphere 106 G SET SET Pad side