p/rev)Single phase 100 to 120 VAC (50/60 Hz)Single phase 85 to 132 VAC3.0Single phase 100 to 120 VAC (50/60 Hz)Single phase 85 to 132 VAC0.4CC-Link communication (Ver. 1.10)CC-Link Ver. 1.10 compliant cable (Shielded 3-core twisted pair cable) 11 to 6416 k12000.2 or more1 station occupied (Remote I/O 32 points/32 points)/(Remote register 4 words/4 words) 2 stations occupied (Remote I/O 64
points/64 points)/(Remote register 8 words/8 words)Up to 42 (when 1 station is occupied by 1 driver), Up to 32 (when 2 stations are occupied by 1 driver), when there are only remote device stations.Available with CC-Link communication (2 stations occupied)Available with CC-Link communication, RS-422 communication CC-Link communication (1 station occupied): 31 pointsCC-Link communication
11 to 6410 M1000.2 or more1 station occupied (Remote I/O 32 points/32 points)/(Remote register 4 words/4 words) 2 stations occupied (Remote I/O 64 points/64 points)/(Remote register 8 words/8 words)Up to 42 (when 1 station is occupied by 1 driver), Up to 32 (when 2 stations are occupied by 1 driver), when there are only remote device stations.Available with CC-Link communication (2 stations
p/rev)Single phase 100 to 120 VAC (50/60 Hz)Single phase 85 to 132 VAC5.0Single phase 100 to 120 VAC (50/60 Hz)Single phase 85 to 132 VAC0.4CC-Link communication (Ver. 1.10)CC-Link Ver. 1.10 compliant cable (Shielded 3-core twisted pair cable) 11 to 64625 k9000.2 or more1 station occupied (Remote I/O 32 points/32 points)/(Remote register 4 words/4 words) 2 stations occupied (Remote I/O 64
Please contact us for the latest version.sales@ocaire.com, 64/64 IO SI UNIT, PROFIBUS, VALVE, EX500 SERIAL INTERFACE UNIT, 22, EX500 NO SIZE RATING, 1.74299 lb
Each module is capable of 128 inputs and 64 outputs. EX245 series is also compatible with PROFINET MRP® (Media Redundancy Protocol) and Provides Fast Start Up function to reduce donwtime and improving machine productivity.
Each module is capable of 128 inputs and 64 outputs. EX245 series is also compatible with PROFINET MRP® (Media Redundancy Protocol) and Provides Fast Start Up function to reduce donwtime and improving machine productivity.
GW system, 4 branches; Valve & input unit manifolds can be connected around the GW unit; Compatible with 64-digital-outputs & 64-digital-inputs; GW unit, input unit manifold: IP65; Valve manifold including SI unit: IP67
EX510 can comment up to 64 outputs and 64 inputs. Available protocol include CC-Link, DeviceNet™, and Profibus®. Up to 16 solenoids; Up to 4 manifolds can be connected to one EX510 gateway; Available with positive and negative common specification
The RMHF2 series offers 64 mm long stroke, which is ideal for a variety of workpieces. 2-Finger, Standard Type; Opening/Closing stroke: 64 mm; External Gripper Force(N): 90; Internal Gripping Force (N): 90; Manual changer built-in; Actuator position sensor mountable
The RMHF2 series offers 64 mm long stroke, which is ideal for a variety of workpieces. 2-Finger, Standard Type; Opening/Closing stroke: 64 mm; External Gripper Force(N): 90; Internal Gripping Force (N): 90; Manual changer built-in; Actuator position sensor mountable
EX510 can connect up to 64 outputs and 64 inputs. Available protocol include CC-Link, DeviceNet™, and PROFIBUS®. Plug lead serial transmission, S kit; Decentralized serial EX510; Up to 8 stations available as standard
EX510 can connect up to 64 outputs and 64 inputs. Available protocol include CC-Link, DeviceNet™, and Profibus®. Up to 16 solenoids; Up to 4 manifolds can be connected to on EX510 gateway; Available with positive and negative common specification
EX510 can connect up to 64 outputs and 64 inputs. Available protocol include CC-Link, DeviceNet™ and PROFIBUS®. Up to 16 solenoids; Up to 4 manifolds can be connected to one EX510 gateway; Available with positive and negative common specification
GW system, 4 branches; Valve & input unit manifolds can be connected around the GW unit; Compatible with 64-digital-outputs & 64-digital-inputs; GW unit, input unit manifold: IP65; Valve manifold including SI unit: IP67
Each module is capable of 128 inputs and 64 outputs. EX245 series is also compatible with PROFINET MRP® (Media Redundancy Protocol) and Provides Fast Start Up function to reduce donwtime and improving machine productivity.
The RMHF2 series offers 64 mm long stroke, which is ideal for a variety of workpieces. 2-Finger, Standard Type; Opening/Closing stroke: 64 mm; External Gripper Force(N): 90; Internal Gripping Force (N): 90; Manual changer built-in; Actuator position sensor mountable
Thrust, speed and positioning (64 points) can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes: 16, 25, 32; Compatible with slide bearing and ball bearing; Speed control/positioning: maximum 64 points; RoHS compliant
EX510 can connect up to 64 outputs and 64 inputs. Available protocol include CC-Link, DeviceNet™, and Profibus®. Up to 16 solenoids; Up to 4 manifolds can be connected to one EX510 gateway; Available with positive and negative common specification
EX510 can connect up to 64 outputs and 64 inputs. Available protocol include CC-Link, DeviceNet™, and Profibus®. Up to 16 solenoids; Up to 4 manifolds can be connected to on EX510 gateway; Available with positive and negative common specification