The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
Effective oil level stroke (mm) Converter nominal size/stroke (mm) 50, 100, 200, 300, 400, 500 100, 200, 300, 400, 500, 600 200, 300, 400, 500, 600, 700, 800 63 100 160 Specifications Operating pressure 0 to 0.7 MPa Proof pressure 1.05 MPa 5 to 50C Ambient and fluid temperature Fluid Turbine oil (40 to 100 mm2/s) Converter Standard Effective Oil Level Stroke/Effective Volume (cm3) Converter
Note 2)) 5 to 50C Note 1) (Air operated type: 60C) Pressure range External pilot air Lubrication Temperature Unrestricted Note 3) Mounting orientation Note 1) No freezing Note 2) Lubrication is not allowed for use with EPR seal material. Note 3) For external pilot solenoid, it is recommended that the pilot solenoid valve be oriented either vertically upward or horizontally.
Air Operated only) Ambient temperature External pilot solenoid VNB0 B C 2 1 1 2 5 to 50C Note 1) (Air operated type: 60C) 1.5 MPa Low vacuum to 0.5 MPa Low vacuum to 1 MPa 0.25 to 0.7 MPa 0.1 + 0.25 x (Operating pressure) to 0.25 + 0.25 x (Operating pressure) MPa Note 3) Refer to Graph (1) on page 568. Not required (Use turbine oil Class 1 ISO VG32, if lubricated.
Lubrication Temperature Allowable voltage fluctuation Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5 to 50C (Air operated type: 60C) Note 1) SGC 35C or less (when rated voltage is applied.) 50C or less (when rated voltage is applied.)
Pilot Operated Solenoid Valve Specifications VO307D DZ1(-Q) DIN terminal Pilot solenoid valve Electrical entry Coil rated voltage (V) AC (50/60 Hz) DC 100 V, 200 V, Other voltage (Semi-standard) 24 V, Other voltage (Semi-standard) 15 to +10% of the rated voltage Allowable voltage fluctuation Temperature rise 50C or less (When rated voltage is applied.)
Flow rate characteristics: C Max. operating frequency 0.8 MPa 0.15 MPa 5 to 50C 0.60 dm3/(sbar) 180 c.p.m SZ SUP side pressure (P1) To CYL port VVQ1000-FPG-02 1 set VQ1000-FPG-C6M5-D 2 pcs.
Buffer stroke 40 50 63 80 100 125 Series ZPT ZPX Related 25 50 75 100 Equipment Pad Material and Characteristics Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Base resistance Acid resistance Weatherability Ozone resistance Abrasion resistance Waterproof Solvent resistance (Benzene, toluene) Durometer HS (5C) Material 50C 50C 50C 60C 60C NBR
Use a pressure gauge below 50C. The Max. operating temperature of the standard accessory Pressure gauge is 50C. If temperature of the air tank exceeds 50C, provide a heat radiator (i.e. pipe siphon, etc.) between the tank and the pressure gauge. 3. Please keep the Class 2 Pressure Vessel Certificate in a safe place.
type. 10-16-4 5 Valve Mounted Guide Cylinder Series MVGQ Specifications JIS Symbol Meter-out 12, 16, 20 Bore size (mm) Rod extended when energized Rod retracted when energized Double acting Action Air Fluid Slide bearing (MVGQM), Ball bushing bearing (MVGQL) Bearing type Operating pressure range (MPa) 2 position single 0.15 to 0.7 12, 16: 0.12 to 0.7, 20: 0.1 to 0.7 2 position double 10 to 50C
The specified ambient temperature range for ionizer is 0 to 50C, and for AC adapter is 0 to 40C. Avoid sudden temperature changes even within specified ambient temperature range, as it may cause condensation. 2. Do not use this product in an enclosed space. This product utilizes a corona discharge phenomenon.
Fluid and ambient temperature ranges are 0 to 50C for the ionizer, feedback sensor and autobalance sensor. Do not use the ionizer in locations subject to sudden temperature changes even if the ambient temperature range is within the specified limits, as condensation may result. 2. Do not use this product in an enclosed space.
5 to 40C 5 to 50C Operating temperature range Electric power 640VA 300VA 640VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction Maximum positioning point setting Can be selected between the motor side and the side opposite the motor. 1008 points (when step designation is actuated) Movement command Absolute and
Enclosure IP67 equivalent (with manifold assembled) Ambient temperature (Operating temperature) 10 to +50C Ambient temperature (Storage temperature) 20 to +60C Ambient humidity 35 to 85% RH (No condensation) General Withstand voltage 500 VAC for 1 minute between external terminals and metallic parts Insulation resistance 10 M or more (500 VDC between external terminals and metallic parts)
sResponse timeHysteresisPower supply voltageResistancePF2W711Water7 to 110 l/min7 to 110 l/min10 to 100 l/min1 l/min1 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less1150 g3/4, 1Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
50 kPa to 0.5 MPa1.0 MPa0 to 50C?5% F.S. or less?1% F.S. or less (Connected with PF2A3 ), ?3%F.S. or less (Connected with PF2A2 )?2% F.S. or less (15 to 35C, based on 25C)?3% F.S. or less (0 to 50C, based on 25C)Analog voltage output (non-linear) output impedance 1 k output for display unit PF2A3Voltage output 1 to 5 V (within the flow rate range)Linearity: ?