(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).
6.2 (160) () () 110 95 20 95 B (140) () () Dimensions A Stroke Model B C D Note) LG1H202100-F LG1H202200-F LG1H202300-F LG1H202400-F LG1H202500-F LG1H202600-F LG1H202700-F LG1H202800-F LG1H202900-F LG1H202-1000-F LG1H202-1200-F 100 200 300 400 500 600 700 800 900 1000 1200 245.7 345.7 445.7 545.7 645.7 745.7 845.7 945.7 1045.7 1145.7 1345.7 400 500 600 700 800 900 1000 1100 1200 1300 1500
Rotating Torque/Permissible Number of Rotations Applicable tube O.D. 5/32/4 1/4/6 5/16/8 3/8/10 12 Rotating torque in-lbf (Nm)NOTE 1) 0.053 0.106 0.124 0.177 0.195 (0.006) (0.012) (0.014) (0.020) (0.022) Permissible number Series KS 500 500 400 300 250 of rotations Series KX 1500 1200 1200 1000 1000 Note) Value under pressure 73psi (0.5MPa).
Features 2 Series LJ1 Electric Actuator Series Variations Maximum work load (kg) Maximum speed (mm/sec) Positioning repeatability (mm) Stroke (mm) Motor output (W) Guide type Typical model Mounting position Series Feed screw 100 200 300 400 500 600 700 800 900 1000 1200 1500 Ground ball screw Lead 12mm 0.02 Horizontal Vertical 1) 600 10 Rolled ball screw Lead 12mm 50 0.05 0.1 500 Slide screw
The dryer comes already fitted with tubing in flexible plastics (6 mm in diameter and 1500 mm long) for the connection to the collection plant. The condensate drain occurs through a solenoid valve protected with a mechanical filter. In order to avoid clogging of the solenoid valve, the condensate coming from the cyclone separator is previously filtered, than discharged.
Specifications Body Size (in.) 1/4 3/8 1/2 3/4 1 1-1/4 1-1/2 2 Maximum Rated Pressure (PSI) 5000 5000 5000 5000 4000 4000 4000 3000 Except the following port options in the noted size 03 (Male JIC 37) 3000 2000 05 (Male SAE O-Ring Boss) 2500 06 (Female JIC 37) 90 Housing Port 4000 3000 3000 2500 2000 06 (Female JIC 37) In-Line Housing Port 3000 2000 07 (Female NPSM) 4600 3000 2600 2100 1650 1500
Rated voltage (with connector and 2 of sockets only) Lead wire length Nil 300 mm 6 600 mm Electrical entry 5 24 VDC 6 12 VDC 10 15 20 25 30 50 1000 mm G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm V 6 VDC S 5 VDC L With lead wire L plug connector R 3 VDC LN Without lead wire 50 60 1 100 VDC Hz LO Without connector With lead wire Without lead
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -25- 5.3.3 Acceleration/deceleration time configuration < Acceleration/deceleration time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount
Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -36- 6.6.3 Acceleration/deceleration Time Configuration < Acceleration/deceleration Time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount
Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -38- 6.6.3 Acceleration/deceleration Time Configuration < Acceleration/deceleration Time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount
ZL3 ZL6 ZL6 14 1 7 15 PBT 2 POM 16 POM 2 3 PBT 17 PBT 4 POM 18 5 FKM 6 PBT 19 7 PBT 3 6 8 1 PBT 20 , 9 1 4 1 10 2 21 11 2 PBT 5 22 12 POM 8 13 3 O HNBR/NBR 16 No.ZL3-OM00801-A 7.2 1 (/) ZL3/ZL6 ZL3-JSY3140-5LZ -a 1 3) 2) DC24V 1) 300mm 300mm * *0.150.18Nm 2) D: E: 1 1 1 1 3) 1 1 2 X12 ZL3/ZL6 SY100-30-4A-6 1 2) / 1) 2) 300 4 DC24V 6 600 10 1000 15 1500
IDFA100F150F 5 1 5.1 IDX-OM-U022 5. ( ) ( ) 60cm 1 10% 3 ( ) 60cm 1 2 INOUT INOUT () IDFA100F150F 5 2 5.1 IDX-OM-U022 5. 5.2 1-3 5.1 3.7 OFF () ON OFF ON IDFA100F150F 5 3 5.2 IDX-OM-U022 5. 5.3 R () OFF OFF OFF ON ON IDFA100F150F 5 4 5.3 R IDX-OM-U022 6. ence 6.1 IDFA100F-38IDFA125F-38IDFA150F-38560 MPa 0.151.0 / K 0.151.6 () 245 (85%) (ANR) 1 ) 960 1210 1500
SI unit and input devices are connected ) Communication method Protocol: Dedicated for SMC Speed: 750kbps Number of branches for input/output 4 branches ( 16 points/branch ) for input 4 branches ( 16 points/branch ) for output Loop resistance 110 /km Capacity 30pF/m or less Impedance 135 165 Cable length [m] 1200 1000 400 200 100 Transmission rate [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500
DC-DC Converter (Insulation) 19.2 kbps 45.45 kbps 93.75 kbps 187.5 kbps Communication speed Max. wiring length 9.6 kbps 1200 m 1000 m GND +24 V TD+ TD0 V Power supply for output INPUT OUTPUT 100 m Max. wiring length Communication speed 500 kbps 1500 kbps 3000 kbps 6000 kbps 12000 kbps 400 m 200 m +24 V 0 V COM D : Max. wiring length differs depending on the specification of a cable.
005 500 mm SSPS 010 1000 mm SAPA 020 2000 mm 030 3000 mm 050 5000 mm 100 10 mm (EX9-ACMJ-SSPS) (EX9-ACMJ-SAPA) CC-Link A code A code 54 7.7 mm 0.5 mm 2/AWG20 0.34 mm 2/AWG22 2.55 mm 77 mm -30No.EX-OMP0004CN-I (1) EX9-AC0 1 0-1 L 1 1000[mm] 3 3000[mm] 5 5000[mm] B code No. 6.6 mm 1 DC24 V() AWG22 2 0 V() 1.65 mm 3 DC24 V() 40 mm 4 0 V() 5 (2)(SPEEDCON ) PCA-140180 7 L 7 1500
PCT200 W/ SIEM S7-1500 PLC & FAULT INS, TRAINING EQUIPMENT, H25, 12.70000 lb
Auto switches are available on most models.Tie-rod type low pressure hydraulic cylinder, Bore sizes *: 40, 50, 63, 80, 100, 125, 160, Standard strokes *: 25 to 1500, 3.5MPa, 8 mounting styles, Aluminum tube type is auto switch capable, Hydraulic Cylinder, HYDRAULIC CYLINDER, CH, CC, HC, 345, 11.30000 lb
Auto switches are available on most models.Tie-rod type low pressure hydraulic cylinder, Bore sizes *: 40, 50, 63, 80, 100, 125, 160, Standard strokes *: 25 to 1500, 3.5MPa, 8 mounting styles, Aluminum tube type is auto switch capable, Hydraulic Cylinder, HYDRAULIC CYLINDER, CH, CC, HC, 345, 13.08000 lb