SMC Corporation of America
Elite Part Number Search
Search Results "PF2D540-19-1-C"

D ZS-24-D X X X ZS-35-C X X X X X E ZS-35-D X X ZS-35-F X X X X X + F ZS-35-G X X 1/ 1 ZS-24-A A M35 L,M45 L 2 ZS-24-B B M45 L, 2 ZS-24-D D M35 L,M45 L 2 ZS-35-C (01,N01) ZS-35-D (W1,WF1,M5,C4,C6) ZS-35-F +(01,N01) ZS-35-G +(W1,WF1,M5,C4,C6) -10No.PS-OMM0006CN-E M8(3 ) 01 N M L ISE40A 1/ 2 ISE40A -0.11.000 MPa Y ZSE40A 0.0-101.3 kPa K + T + 1 01 R1/8(M5) N01 NPT1/8(M5) A A

62 AWG20 (24V0V) 60 EMG AWG20 EMG+,EMG60 8mm 23 - D (100 ) D 63 CN2SW(EMG+,EMG-) LECEMG CN2SW RY CN4 CN2 EMG+ EMG24V 0V CN2SW EMG+,EMG-(LEC) (LEC)EMG+,EMG-OPEN 24 - (LEC) LEC6 (DC24V 0V ) Ry EMG+ Ry EMG(1 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V LECOFF 25 - 7CN3: 1 5 4 3 2 1

RLQ MLU View A-A' ML1C DStandard Stroke BP BZ C D E F G GC A AA AB AC AD AE AF AP B Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 135 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 118 28 35 32 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 104 19 75 160 50 140 29 40 37 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5

RLQ MLU View A-A' ML1C DStandard Stroke B AF AP E A AA AB AC AD AE BP BZ C D F G GC Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 32 35 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 28 135 118 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 19 104 75 37 40 50 29 160 140 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5

Mounting Bracket/Accessories L: Foot Note F: Front flange G: Rear flange C: Single clevis D: Double clevis Mounting bracket B: Basic (1 pc.) (1 pc.) (2 pcs.) (1 pc.) Note 2) Note 1) Standard Mounting nut Note 1) Rod end nut Clevis pin With pin T-bracket Option Note 1) Mounting nut is not included with integral clevis, single clevis and double clevis types.

(A P) Flow characteristics Weight (g) Operating pressure range (MPa) 1 2 (P A) 2 3 (A R) Port size Valve model C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet 0.44 0.40 0.40 0.44 0.40 0.41 0.63 0.63 0.41 0.63 0.13 0.10 0.10 0.13 0.10 0.20 0.14 0.14 0.20 0.14 VK332 0.47 0.41 0.41 0.47 0.41 0.85 0.65 0.65 0.85 0.65 0.47 0.38 0.38 0.47 0.38 0.76

Nil AS AT A BS Note 1) Without adjuster Extension end Retraction end Both ends Extension end Retraction end Both ends Extension end Retraction end Both ends Option combinations Rubber stopper Functional option Adjuster option Nil F R P FR FP Shock absorber BT Note 1) Nil B Note 1) Note 3) Note 3) Note 3) AS, CS CS CT C Metal stopper x x AT, CT x x Note 3) x x A, C x x Note 1) Series MXQ6

x l 250 M16 x l 300 M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2

+ COM (For COM specifications, specify them separately.) 1 3 5 6 VZ1120MOZ-M5 Applicable valve model Rated voltage 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Note 1) Value at manifold base mounted, single operating Note 2) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.

MH*-OMD0082-A PRODUCT NAME Parallel Type Air Gripper MODEL / Series / Product Number MHZ2-6 MHZJ2-6 MHZA2-6 MHZAJ2-6 Contents Safety Instructions 1. Product Specifications 1-1. Specifications 2. Operating method or operation 2-1. Design precautions 2-2. Selection 2-3. Mounting 2-4. Air supply 2-5. Piping 2-6. Operating environment 2-7. Lubrication 3. Maintenance 3-1. Precautions 3-2.

SI No. 1 COM M OUT 1 COM 0V 2 3 P OUT 1 Zone 1 4 SOL 0 0 Zone 1 ON Zone 1 11 SOL 7 7 Zone 1 ON 12 P OUT 2 Zone 2 13 SOL 8 8 Zone 2 ON Zone 2 20 SOL 15 15 Zone 2 ON 21 P OUT 3 Zone 3 22 SOL 16 16 Zone 3 ON Zone 3 29 SOL 23 23 Zone 3 ON 30 N. C. N.

Content 0 1: There is an error in the digital input unit. 1 1: There is an error in the digital output unit. 2 1: There is an error in the analogue input unit. 3 1: There is an error in the analogue output unit. 4 1: There is an error in the SI unit. 5 Reserved 6 Reserved 7 Reserved -66No.EX-OMN0028-B Unit standard diagnostic data Header 7 6 5 4 3 2 1 0 Byte 19 0 1 0 0 1 0 0 1 Bit No.

M26 x 1.5 Rc(PT) 1/4 70 43 16 11 29 50 16 92 M6 x 1.0 x 10 21 46 19 M32 x 2.0 S W X ZZ R T Model REA25 REA32 REA40 111 50 30 137 8 17 124 50 40 156 8 17 150 60 40 182 10 19 REA 50, 63 14 2 -Rc(PT) 1/4 L 0 0.2 NA 33 14 E(h8) E(h8) X PD I 4 -TC Effective thread depth R 14 8 -Q Effective thread depth R 14 22 23 25 K W 23 25 4 -M8 x 1.25 Effective thread depth 12 C 0.1 14.5 B 2 S + Stroke 2

(mm) M Effective area (mm 2) Weight (g) A L2 L1 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 DL04-01 15 3.5 23 DL04-02 17 19 4 10 23.5 19.6 10 30 DL06-01 25 17 Applicable tubing 19.6 10 23.5 DL06-02 16 19 31 14 6 9 12 DL06-03 22 53 26.5 24.5 21.6 22.6 24.5 25.8 24.5 29.4 29.6 30.3 29.4 91 Reference dimensions after R thread installation.

Single end lock Double end lock Content Bore size (mm) Bumper 17 Urethane C-ring 18 Steel wire Zinc chromated 40 50 63 80 100 MBB40-PS MBB40-PS-W Seal retainer 19 Rolled steel Zinc chromated Consists of numbers #0, #1, #2, #4, and #6 above.

g Effective area mm2 L1 L2 KKA3P-01F-1 Rc 1/8 9.6 23.2 14 -02F-1 1/8 T Rc 1/4 16.0 6.0 22.6 20.2 30.3 17 -03F-1 Rc 3/8 26.2 32.0 19 KKA4P-02F-1 Rc 1/4 20.0 29.7 17 -03F-1 1/4 Rc 3/8 18.9 8.0 40.2 25.8 34.0 19 -04F-1 Rc 1/2 46.1 39.4 24 L2 H KKA6P-03F-1 Rc 3/8 34.3 30.9 22 L1 -04F-1 1/2 Rc 1/2 20.4 11.0 76.0 50.0 39.6 24 -06F-1 Rc 3/4 78.6 42.8 30 Dimensions/Socket (S) Without check valve

24 5 19 14.5 11.5 15 10 5 25 19 M22 X 1.5 20.5 4.5 17.5 15 31.5 27 24 Panel Mounting Style CJPB B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14

Only when output 1 and 2 are in the ON state, and C turns ON, will output 3 turn ON. If either A or B is turned OFF , output 3 will not be turned ON, even if C is turned ON.