Formula CRA1 F1 = x A1 x P (1) F2 = x A2 x P (2) A1 = D2 (3) 4 CRQ2 MSQ A2 = (D2 d2) (4) 4 MSZ CRQ2X MSQX F1 = Cylinder force generated on the extending side (N) F2 = Cylinder force generated on the retracting side (N) = Load rate A1 = Piston area on the extending side (mm2) A2 = Piston area on the retracting side (mm2) D = Tube bore size (mm) d = Piston rod diameter (mm) P = Operating
L RR,IU1 E, A, L, t MM NX Part no A2 NDHIO boreSlzc D
A1 (mm) Note 2) Operating range Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 B1 B2 B3 (mm) 10 15 25 5.5 34 64 22 76 34 76 5 35 70 23 82 35 82 Mounting pattern w B2 A2 5 40.5 99.5 28.5 111.5 40.5 111.5 Note 1) Adjust the auto switch after confirming the operating conditions in the actual setting.
Nozzle Diameter: 1.3 mm, Vacuum Pressure: -53 kPa, Exhaust: Built-in Silencer, Valve: Air Operated, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Manual Override: -, Switch/Filter: -, Output: -, Unit Specification: -, Lead Wire: -, Adjusting Needle/Bracket: -, CE Compliant: -
Nozzle Diameter: 1.3 mm, Vacuum Pressure: -84 kPa, Exhaust: Built-in Silencer, Valve: Air Operated, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Manual Override: -, Switch/Filter: -, Output: -, Unit Specification: -, Lead Wire: -, Adjusting Needle/Bracket: -, CE Compliant: -
Nozzle Diameter: 1.5 mm, Vacuum Pressure: -53 kPa, Exhaust: Built-in Silencer, Valve: Air Operated, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Manual Override: -, Switch/Filter: -, Output: -, Unit Specification: -, Lead Wire: -, Adjusting Needle/Bracket: -, CE Compliant: -
Nozzle Diameter: 2.0 mm, Vacuum Pressure: -84 kPa, Exhaust: Built-in Silencer, Valve: Air Operated, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Manual Override: -, Switch/Filter: -, Output: -, Unit Specification: -, Lead Wire: -, Adjusting Needle/Bracket: -, CE Compliant: -
Valve: Air Operated, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Manual Override: -, Switch/Filter: -, Output: -, Unit Specification: -, Lead Wire: -, Adjusting Needle/Bracket: -, CE Compliant: -
Output Specification: Voltage Output Type (1~5V), Option 1: None, Option 2: Connector 1 pc. for Pressure Sensor Controller
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SENSOR, GENERAL FLUID SWITCH, INSTRUMENTATION, PSE200/300/530-560, DX, PSE200/300/530-560 1/4, .65737 lb
Series PSE digital pressure switches allow pressure to be controlled from a remote location. Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Pressure sensor for general
Series PSE digital pressure switches allow pressure to be controlled from a remote location.? Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Pressure sensor for general
Designation Description Fieldbus interface connector (BUS IN) EtherNet/IPTM connection PORT 1 (M12 4-pin socket, D-coded) 4 2 SI24 V +24 V for SI unit operation 2 1 SV24 V +24 V for solenoid valve 2 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 4-pin plug, A-coded) 3 1 3 SI0 V 0 V for SI unit operation MS NS L/A1 L/A2 PWR(V) 4 Ground
Element Description Safety Instructions S/E ST L/A1 PWR(V) L/A2 Fieldbus interface connector (BUS OUT/Port2) 1 POWERLINK connection PORT 2 (M12 4-pin socket, D-coded) LED Status Description These safety instructions are intended to prevent hazardous situations and/or equipment damage.
L/A2 Displays the communication status of the BUS OUT side. ST(M)-LED LED display Content OFF The power supply for control and input is OFF. Green ON Normal operation. Diagnostic error of I/O unit is detected. Green flashing Valve is short circuited or disconnected. Red flashing Detect a communication error between SI unit and I/O unit.
OUT2 will operate with Auto shift function, when "A2" is selected. The operating value of OUT2 applies corrected value [P_3], [P_4] or [n_3], [n_4]. Both OUT1 and OUT2 will operate with Auto shift function, when "Ab" is selected. The operating value of OUT1 and OUT2 applies corrected value [P_1] to [P_4] or [n_1] to [n_4].
. -63No.PF-OMA1007-B Right-click on the selection [A1/A2, Ethernet] in the [I/O Configuration] folder, and select [New Module]. The [Select Module Type] screen is displayed.
Current consumption Compatible encoder Incremental A/B phase (800 pulse/rotation) Battery-less absolute encoder ( 4096 pulses/rotation) LED Details L/A1 Link/Activity1 L/A2 Link/Activity2 LED display PWR Power supply ALM Alarm status RUN EtherCAT communication status. ERR EtherCAT communication error status.
Red LED is flashing EtherNet/IP connection time out Red LED is ON IP duplicated OFF BUS IN side (P1): No Link, No Activity L/A1 Link/Act Green LED is ON BUS IN side (P1): Link, No Activity Green LED is flashing BUS IN side (P1): Link, Activity OFF BUS OUT side (P2): No Link, Activity L/A2 Link/Act Green LED is ON BUS OUT side (P2): Link, No Activity Green LED is flashing BUS OUT side (P2)