Type: Base for Manifolds, Communication Protocol: EtherNet / IP Compatible, Output Format: PNP Sensor Input, Type: EX250 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (without DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-,
Type: Base for Manifolds, Communication Protocol: EtherNet / IP Compatible, Output Format: PNP Sensor Input, Type: EX250 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø5/16" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-, E-Port
Type: Base for Manifolds, Communication Protocol: EtherNet / IP Compatible (2-Port), Output Format: PNP (Negative Common), Type: EX600 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: M12 Connector Power Supply (maximum supply current: 2A), Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting
Type: Base for Manifolds, Communication Protocol: EtherNet / IP Compatible (1-Port), Output Format: PNP (Negative Common), Type: EX600 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: M12 Connector Power Supply (maximum supply current: 2A), Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: EX500, 128 Points Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (without DIN rail), Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action pipe fitting (P-, E-Port), Specification:
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: EX500, 128 Points Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (without DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-, E-Port), Specification
Enclosure: IP67, SI Unit: for DeviceNetâ„¢, End Plate Type: Power Supply with 7/8" Connector, Max. Supplied Current 8 A, SI Unit Common: Negative Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/o DIN Rail, DIN Rail Option: -
Enclosure: IP40, SI Unit: for PROFIBUS DP, End Plate Type: Power Supply with M12 Connector, Max. Supplied Current 2 A, SI Unit Common: Positive Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/o DIN Rail, DIN Rail Option: -
Enclosure: IP67, SI Unit: for PROFIBUS DP, End Plate Type: Power Supply with M12 Connector, Max. Supplied Current 2 A, SI Unit Common: Positive Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/o DIN Rail, DIN Rail Option: -
Enclosure: IP40, SI Unit: EtherNet/IPâ„¢, 2 Ports, End Plate Type: Power Supply with M12 Connector, Max. Supplied Current 2 A, SI Unit Common: Positive Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/DIN Rail, DIN Rail Option: -
Enclosure: IP40, SI Unit: EtherNet/IPâ„¢, 2 Ports, End Plate Type: Power Supply with M12 Connector, Max. Supplied Current 2 A, SI Unit Common: Negative Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 5/16" One-touch Fitting, Mounting: DIN Rail Mounting, w/o DIN Rail, DIN Rail Option: -
Enclosure: IP67, SI Unit: EtherNet/IPâ„¢, 2 Ports, End Plate Type: Power Supply with M12 Connector, Max. Supplied Current 2 A, SI Unit Common: Negative Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 5/16" One-touch Fitting, Mounting: DIN Rail Mounting, w/o DIN Rail, DIN Rail Option: -
Enclosure: IP67, SI Unit: for EtherNet/IP™, End Plate Type: Power Supply with 7/8" Connector, Max. Supplied Current 8 A, SI Unit Common: Negative Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/o DIN Rail, DIN Rail Option: -
Enclosure: IP67, SI Unit: for EtherNet/IP™, End Plate Type: Power Supply with 7/8" Connector, Max. Supplied Current 8 A, SI Unit Common: Positive Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/DIN Rail, DIN Rail Option: -
Enclosure: IP67, SI Unit: for EtherNet/IP™, End Plate Type: Power Supply with 7/8" Connector, Max. Supplied Current 8 A, SI Unit Common: Negative Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/DIN Rail, DIN Rail Option: -
Enclosure: IP40, SI Unit: for EtherNet/IP™, End Plate Type: Power Supply with M12 Connector, Max. Supplied Current 2 A, SI Unit Common: Negative Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/o DIN Rail, DIN Rail Option: -
Enclosure: IP67, SI Unit: for EtherNet/IP™, End Plate Type: Power Supply with M12 Connector, Max. Supplied Current 2 A, SI Unit Common: Negative Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, w/o DIN Rail, DIN Rail Option: -
Enclosure: IP67, SI Unit: for EtherCAT, End Plate Type: Power Supply with M12 Connector, Max. Supplied Current 2 A, SI Unit Common: Negative Common, I/O Unit Stations: None, Valve Stations: 12 Stations, P, E Port Location: Both Sides, SUP/EXH Block Assy: Internal Pilot, A, B Port Size: ø6 One-touch Fitting, Mounting: DIN Rail Mounting, w/DIN Rail, DIN Rail Option: -
Series: 2 (10-SV2000), Enclosure: W10CD, Valve Stations: 12 Stations, P, E Port Locations: B (Both Sides, 2-20 Stations), SUP/EXH Block Assembly Specifications: Internal Pilot, A, B Port Size: C6 (One-touch Fitting for Ø6)
SI Unit: 1A3N (32 Outputs, 1 to 16 Stations), Stations: 12 Stations, SUP/EXH Block Mounting: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)