SMC Corporation of America
Elite Part Number Search
Search Results "VG342R-5DZ-06-M-X87"

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage

G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell

L M a l e E l b o w . . . . . . L__ Plug-in Elbow .. ... L Union Elbow . . . . . . LF Female Elbow . K 45" Male Elbow . . . KF 45' Female Elbow Y M a l e R u n T e e . . . . . T Male Branch Tee . , T Union Tee , . . . . . . , TF Female Branch Tee E Bulkhead Connector E Bulkhead Union . . , U Male Branch 'Y" . . . U Union "Y" . . . . . . . .

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: B2 [Supply Valve (N.O.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage

Lubrication Manual override Impact/Vibration resistance (2) Enclosure VV061 Non-locking push type 150/50 m/s2 VT325-C VV100 Dustproof Note 1) Based on dynamic performance test, JIS B 8419: 2010.

Compressed air 1.0 MPa Fluid Max. operating pressure Min. operating pressure 0.05 MPa 1.5 MPa Proof pressure Ambient and fluid temperature Filtration degree Element life 5 to 60C 3 m (95% particle size collection) 2 years (1 year for A type) or when pressure drop reaches 0.1 MPa 0.1 MPa (N.O. type) or 0.15 MPa (N.C. type) in the case of types with auto-drain.

M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMG850 1 2 13 42 348 220 57.5 220 10 14-20-7

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm)

(A red color spot indicates the replacing time.) 5 to 60C 0.01m(95% particle size collection ) Oil mist removal rate Less than 3.5 particles 0.3 m or larger per liter of air ( 100 particles or less per cubic foot) Element Color Indicator (When element becomes saturated with oil the element surface changes from white to red.)

8000 AMF801 24000 AMF901 Model Rated flow (l/min (ANR)) Port size (Nominal size B) 2B Flange Weight (kg) 40 2B/3B/4B Flange 120 Specifications Compressed Air 1.0MPa Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient and fluid temperature 0.05MPa 1.5MPa 5 to 60C Filtration rating 0.01m(95% particle size collection) Oil mist removal rate Less than 3.5 particles 0.3 m

Applicable auto switch types / Tie-rod mount Cylinders with built-in magnets Lead wire length (m) 0.5 (Nil) 3 (L) 5 (Z) Load voltage Indicator light Applicable load Auto switch part no. Special functions Type Electrical entry Wiring (output) In cases of built-in magnets without auto switches, the symbol for auto switch type will be Nil. (Ex.) MDNBL40-100-D AC DC 3 wire (NPN equiv.)

J 1n 114 250 3/8 350 112 450 3/4 5 5 0 1 650 1 1i2 850-2 I I Port Sr" I PT pofts ilodel Bracket Beplacement Element AMG150 BM5'I AMG-EL150 02 1/4 (AMG 1s0) 03 3y8 (AMG 250) 04 1/2 (AMG 350) 06 3/4 (AMG 4s0) 1 o 1 ( A M G 5 5 O ) 14 1 1/2 (AMG 6s0) 20-2(AMGsso) AMG250 BM52 AMG-EL25O AMG35O BM53 AMG-EL35O AMG45O BM54 AMG-EL45O AMG550 BM55 AMG-EL55O AMG65O BM56 AMG-EL65O AMG850 BM57 AMG-EL85O

Target position: 100.000[mm] (=10 [m] = 186A0h) Target speed: 100[r/min] (=10 [0.01r/min] = 2710h) Acceleration time constant: 100 [ms] (= 64h) Deceleration time constant: 100 [ms] (= 64h) The setup value is as follows.

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage

E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm)

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage