L1 L2 5 P = 19 14 24.5 (mounting holes) 49.5 11.5 8.5 2 18.5 R P R P 11.5 18 37 11.5 18 37 67.5 59 Max .10 71.5 Pg.7 Manual override (non-locking) 4Rc(PT) 1/8 (ports P, R) 18 25 31 53.5 Approx. 300 (lead wire length) Light (DZ type only) 4Rc(PT) 1/8 (ports P, R) 75.5 83 Manual override (non-locking) nRc(PT) 1/8 (port A) Applicable cord O.D. 4 to 6.5 A A P = 19 20 L: Dimension table n: Stations
v Deionized water v Sodium hydroxide Ultra deionized water v Toluene v Hydrofluoric acid Concentration 50% or less v Sulfuric acid (except fuming sulfuric acid) Concentration 20% or less v Phosphoric acid Concentration 30% or less v Note 1) The material and fluid compatibility check list provides reference values as a guide only.
Set pressure with a flat head screw driver. 42 Base Mounted Type Series VQ5000 Plug-in Unit Metal seal type Rubber seal type (A) 4 (B) 2 VQ5101 (A) 4 (B) 2 VQ5100 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5201 (A) 4 (B) 2 (A) 4 (B) 2 VQ5200 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5301 VQ5300 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5401 VQ5400 (A) 4 (B) 2 (A) 4
[Driving to the intermediate position] 24 V 0 V Power supply (5) Alarm Reset ON OFF Alarm reset IN0-3 Input ON OFF Input RESET ON OFF OUT0-3 ON OFF ALARM Output Output BUSY Alarm out Release Hold ALARM is expressed as negative-logic circuit.
This wiring is common in each mode. (1) Using 3-phase 200 V AC to 240 V AC power supply for LECSN2-T Note 1. Between P3 and P4 is connected by default. 2. Always connect between P+ and D terminals. (Factory-wired) 4.
Front Structure of the product number W R 0001 (2018 April) W R 0001 Year Symbol Note Month Symbol Note Serial No. 2018 2019 2020 2021 W Repeated from A to Z in alphabetical order 1 2 3 4 o P Repeated from A to Z in alphabetical order, with o assigned for January and Z for December.
Plug Series Variations Bore sizes (mm) Seal materials Applicable auto switches 10 16 20 25 32 Series 40 50 63 80 100 Water resistant D-H7BAL CJ5-S NBR FKM Water resistant D-G5BAL CG5-S Related Equipment P. 18 Water Resistant Air Cylinders Speed Controller with One-touch Fittings/Stainless Steel Series AS-FG P. 20 One-touch Fittings/Stainless Steel Series KG P. 21 Miniature Fittings MS P.
(same side) D-Y59A (B), Y69A (B) Y7P (V) 20 1 pc., 2 pcs. (different sides) 70 2 pcs. (same side) D-Y7NW (V), Y7PW (V) Solid state switch Y7BW (V) 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
Unit 'k,gf Bore(mm) 40 50 53 IBasic weight 0.74 0.96 1.23 Cylinder ~ II / E E I Add itional weight per 25 stroke 0.10 0. 11 0.13 <100 // Single knuckle jOint 0.2 J> "V Double knuckle joint(With pin) 0.28 ~ ~ ~ 300 Limit switch mount 0.22 /~/ c E m Cam 0.12 Ii: 200 Special bracket 0.2 ~V Calculation method _ BaSIC weight . . ... . . 0.74 (40) 100 W :/ Example : CKI ()40-IOOY _ Additional
P kit F kit T kit PS (Side entry) FS (Side entry) Note 1) S kit is composed of a flat cable housing assembly (AXT1002PU20) of q SI unit and w P kit (20 pin).
DC (42 mA), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA)
Hysteresis Note 4) Variable from 0 Protection Short circuit protection Switch output Output type Voltage output: 1 to 5 V, Current output: 4 to 20 mA Voltage output Output impedance: Approx. 1 kW Maximum load impedance at power supply voltage 24 V: 600 W, at power supply voltage 12 V: 300 W Minimum load impedance: 50 W Response time Note 6) Linked with the response time of the switch output
2 VQ5250 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5351 (A) 4 (B) 2 VQ5350 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 VQ5451 VQ5450 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5551 (A) 4 (B) 2 VQ5550 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Parts list Parts list Description Material Note No. 1 2 3 Description Material Note No. 1 2 3 Body
(REFRIGERANT) IDFA60-23 W R 0001 (2018 4 ) W R 0001 o 1 Z 12 o P Q R A Z 1 2 3 4 W X y Z 2018 2019 2020 2021 IDFA60/70/80/90 Series 1-4 IDX-OM-W094 1.3 HFC 1-4 IDFA60/70/80/90 Series 1-5 IDX-OM-W094 1.4 / 1 1.5 () IDFA60/70/80/90 Series 1-6 IDX-OM-W094 2 2.1 IN OUT (ONOFF ) 6-4 6-4 L N PE 3-5 IDFA60/70/80/90 Series 2-1 IDX-OM-W094 () IDFA60/70/80/90 Series 2-2 IDX-OM-W094 3
L L+A Fig. 1 Fig. 2 L 2 1 V E = W ( ) 2 1000 Collision speed V = 1.4 Va Find the kinetic energy E (J) of the load. 1 420 E = 1 ( ) = 0.088 2 1000 V = 1.4 x 300 = 420 Correction factor (reference value) Find the allowable kinetic energy Ea (J).
Note 2) Refer to p.5.3-5 for lead wire length.
7 p. 7 Communication plug connector for IO-Link JXC-CD-T JXC-CD-S Straight type JXC-CL-S Straight type T-branch type (Accessory) To SI To ENC To SI To MOT To PWR Provided by customer Communication cable Power supply for controller 24 VDC (3 m) p. 7 Power supply plug p. 7 (Accessory) Options Conversion cable1 Controller setting kit Teaching box p. 7 p. 7 P5062-5 (0.3 m) (With 3 m cable) LEC-T1
IC circuit 5 V, 12 V 3-wire (PNP) Relay, PLC 2-wire 12 V Grommet 5 V, 12 V 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 12 V 2-wire Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) A93L 5 mZ (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-10-22 for details.
Lead wire length* (m) Load voltage Auto switch model Electrical entry Indicator Wiring (Output) 3 (L) 5 (Z) Applicable load Special function Style 0.5 () (N) AC DC P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P C76 IC circuit P P P P P p p p P p p p p p p p P P P P P P P P 3 wire (Equiv. to NPN) 5V Yes C73 100V 12V Relay PLC C80 IC circuit No 100V