Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
B 1.8 1.6 Groove position of auto switch A 10.4 12.8 Model MHK2-12 MHK2-16 A B Dimensions A and B of other models are same as standard switch grooves. Standard switch grooves 12-6-17
B 1.8 1.6 Groove position of auto switch A 10.4 12.8 Model MHK2-12 MHK2-16 A B Dimensions A and B of other models are same as standard switch grooves. Standard switch grooves 12-6-17
MHW2 Groove position of auto switch A Model MHK2-12l MHK2-16l A 10.4 12.8 B 1.8 1.6 MRHQ B Auto switch Standard switch grooves Dimensions A and B other models are same as standard switch grooves. 2.4-17
How to Use PneuAlpha Series Controllers Getting Started. 21 5.
B Locking ' Special Order option t Consult factory for availability NVF 1100-ODO{IT (drx ) Lamp and Sorga Protec-tion Z rv/Lamp/Surge Protection S dsurqe Protection Onlv L.mp and S dsurge Only BRACKET (Sutfix "F') .[ otMEr{stoNs A B c D E F 1.35 (34.41 1.34 (34.11 0.61 115.4) 0.83 Q 1 t 1.76 1.77 (44.9) Millamte.s in Parenthe$s rxfENsroNs A B c D E F G H J K It N o P o R 64.7) 0.83 (21) l.t
Test operation . 21 5.1 Operation procedure . 21 5.2 JOG Mode . 22 5.3 Positioning Mode . 23 5.3.1 Positioning Mode . 24 5.3.2 Motor speed configuration . 25 5.3.3 Acceleration/deceleration time configuration . 26 5.3.4 Move distance Configuration and Operation . 27 6.
B Locking ' Special Order option t Consult factory for availability NVF 1100-ODO{IT (drx ) Lamp and Sorga Protec-tion Z rv/Lamp/Surge Protection S dsurqe Protection Onlv L.mp and S dsurge Only BRACKET (Sutfix "F') .[ otMEr{stoNs A B c D E F 1.35 (34.41 1.34 (34.11 0.61 115.4) 0.83 Q 1 t 1.76 1.77 (44.9) Millamte.s in Parenthe$s rxfENsroNs A B c D E F G H J K It N o P o R 64.7) 0.83 (21) l.t
A port 1/8, 1/4 NPTF P,R port 1/8, 1/4 NPTF X port (External pilot) M5 0.8 17 Series SYJ700 3 Port Solenoid Valve Manifold Specifications Manifold Specifications For internal pilot Type 20 Type 21 Type 40 Type 41 Type 42 Type For external pilot Type 21R Type 41R Type 42R Manifold type Single base type /B mount P(SUP), R(EXH)Type Common SUP, Common EXH Valve stations 2 to 20 stations Location
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Rubber Bumper
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Rubber Bumper, Series: J2
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: J79C--Solid State, Gen. Purpose, 2 Wire, Connector, Vertical, Lead Wire or Prewired Connector: 3m, Number: 3 pcs., Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -, Series:
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A73, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BA, Lead