SMC Corporation of America
Elite Part Number Search
Search Results "DMK6-04-C1"

Please contact us for the latest version.sales@ocaire.com, BODY ASSY, AIRLINE EQUIPMENT, AMD MICROMIST SEPARATOR, C1, AMD 1/8INCH PART, 0.385 lb

Please contact us for the latest version.sales@ocaire.com, LUBRICATOR MAINTENANCE KIT, AIRLINE EQUIPMENT, AL MASS PRO, C1, AL MASS PRO 1/8 PART, .22880 lb

Part Number Description: BRANCH, BLOCK   Product Line: O   Product Line Description: OTHERS   Family Code: 914   Family Description: FHG HYDRAULIC FILTER   Class Code: C1   Click here to report information errorImage shown may not match exact part number

VDW 2 0 1 B 1 Series Lead wire length OUT (2) 1 2 3 10 20, 200 30, 300 300mm 600mm Nil L1 Note) Note) Type L1 is optional. (1) IN 2 port valve Voltage Type Note 1) Maximum operating pressure differential MPa (psi) 1 2 3 4 5 6 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC Orifice size mm B C1 C2 20, 200 10, 30 300 Model Pressure port 2 Note 1) Pressure port 1 1 0.4 (58) 0.9 (130.5) VDW10 1.6 0.2

Auto switches are available AC /DC and in reed, solid state and 2 color output.Magnetically coupled rodless cylinder, Type: slide bearing, Bore size (mm): 6, 10, 15, 25, 32, 40, Maximum stroke: 60" (depending on size), Auto switch capable, ADJUST BOLT, ACTUATOR, NCY1S GUIDED CYLINDER, C1, 6MM NCY1S PART, .01943 lb

Dual rod cylinder with air cushion, Slide bearing or ball bushing bearing, Bore sizes: 20mm, 25mm, 32mm, Standard strokes: 20-100mm, Thread types: M, Rc, NPT, G, Auto switches available, PLATE, ACTUATOR, CXS GUIDED CYLINDER, C1, 6MM CXS PART, .01540 lb, SeriesDescriptionModelTypeNoteVol. no. (for std model)CXSDual rod cylinderCXSStandard type--3 From P. 561

Please contact us for the latest version.sales@ocaire.com, GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .27901 lb, ModelPressure range (1)Indication unitConnection threadNote MPapsiG46-4-02M-C/C1-X40 to 0.4?MPa1R 4M5 (Female thread)Oil-free, With cover ring assembly

Please contact us for the latest version.sales@ocaire.com, GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .35783 lb, ModelPressure range (1)Indication unitConnection threadNote MPapsiG46-4-02M-C/C1-X40 to 0.4?MPa1R 4M5 (Female thread)Oil-free, With cover ring assembly

Please contact us for the latest version.sales@ocaire.com, MIN QTY 125, ACTUATOR, CJ2 ROUND BODY CYLINDER, C1, 6MM CJ2 PART, .00000 lb, ModelPort sizeMass (Bottom ported)Mass (Rear ported)Leakage02R1/4117 g89 g1 x 10?5 Pa?m3/sN02NPT1/4118 g90 gC01Rc1/8114 g86 g1 x 10?5 Pa?m3/s

Please contact us for the latest version.sales@ocaire.com, VACUUM EJECTOR, C1, CONNECTOR, VACUUM SERIES, ZR MODULAR VACUUM SYSTEM, CH, ZR NOZZLE SIZE 1.0, .72311 lb

Please contact us for the latest version.sales@ocaire.com, VACUUM EJECTOR, C1, CONNECTOR, VACUUM SERIES, ZR MODULAR VACUUM SYSTEM, GH, ZR NOZZLE SIZE 2.0, .73700 lb

Please contact us for the latest version.sales@ocaire.com, EXTERNAL VACUUM, C1, CONNECTOR, VACUUM SERIES, ZR MODULAR VACUUM SYSTEM, 2H, ZR NO SIZE RATING, .77161 lb

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure

. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

Valve Stations: 08 (8 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 5 (24VDC), Coil Specifications: Standard (w/Light Surge Voltage Suppressor)(+COM), Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C1 (Length 300mm), Bracket: F (With Bracket)