Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter), Option 3: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
This is a legacy product, and replaced byAS2201F-N01-07S, INVALID P/N (SGL P/N SYST *LQA, AIRLINE EQUIPMENT, AS***F 1/8INCSTANDARD (NPT), .03968 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air tube, 3 cores
output PNP open collector 1 output NPN open collector 1 output + Analog voltage output NPN open collector 1 output + Analog current output Symbol A B C D ARM ARP Accessory (Pressure gauge) Pressure Switch Specifications Nil None IR1000 series: G33--01 IR2000 series: G43--01 IR-A Set pressure range (MPa) 0.1 to 1 G Resolution of setting and display (MPa) 0.001 IR IR 12 to 24 VDC10%, Ripple (p-p
Lock 1 S Couplers Series KK Variations Plug (P) Socket (S) Male thread type Male thread type Body size Part no. Body size Port size Part no.
and D-A93(V): Oil proof vinyl cabtire cord 2.7 0.18mm22-core (brown, blue) 0.5m D-A96(V): Oil proof vinyl cabtire cord 2.7 0.15mm23-core (brown, black, blue) 0.5m Isolation resistance 50M or more at DC500VM (between lead wire and case) Withstand voltage AC1500V for 1 minute (between lead wire and case) Operating time 1.2ms Ambient temperature -10 to 60C Shock resistance 300m/s2
V 2-wire Refer to page 12-13-25 for solid state switch with pre-wire connector.
V 2-wire Refer to page 12-13-25 for solid state switch with pre-wire connector.
225 psi (1.5 MPa) 60 (0.4) Operating pressure range 30 to 150 psi (0.2 to 1 MPa) A1 A2 A3 45 (0.3) Ambient and fluid temp. 32 to 140F (0 to 60C) 30 (0.2) 113 20 122 37 61 1(P) to 2(A) Effective area (mm2) 132 24 141 49 76 2(A) to 3(R) 15 (0.1) 1.14 (0.64) 1.63 (0.74) 2.21 (1.00) 4.19 (1.90) 4.06 (1.84) Weight manual/solenoid lb (kg) 0 15 30 45 60 75 90 105 120 135 150 Weight manual lb (kg
PNP open collector 2 output + Analogue output Max. 80 mA Residual voltage: 1.5 V or less Bracket A (Part No.: ZS-46-A1) Bracket B (Part No.: ZS-46-A2) DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -