Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04 FLOW CONTROL. SPEED CONTROLLER. 221.00000 lb. SVD.
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch FLOW CONTROL. SPEED CONTROLLER. 5.00000 lb. SVD.
M3 AS-34B AS-36B 4 4 AS-35B AS-37B AS-32B AS-34B AS-36B AS-38B AS-41B AS-42B AS-44B AS-45B M4 M4 4 4 AS-45B AS-42B AS-44B AS-47B AS-46B Precautions when options are ordered Threaded studs for manifold are not included when L-bracket and DIN rail mounting bracket are ordered.
screw (M3 x 0.5 x 10l ) Switch spacer Switch mounting nut Data 50 25 to 600 BQ-2 63 25 to 600 Please contact SMC regarding non-standard strokes.
MVGQ 10 16 20, 25 32 0.54 10% M3 CUX32-PS Grease pack (10 g): 1 pc. 1.23 10% M4 It is impossible to replace seals in bore size 10 mm. CC 2.55 10% M5 4.02 10% M6 2. Grease pack When maintenance requires only grease, use the following part numbers to order. Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1.
Terminal block cover 6mm M3 screw Mounting screw (M4) Gasket Electrical entry 4-G1/2 Step 3. How to replace the terminal block cover Securely tighten the screws to the torque shown in the table below, after confirming that the gasket is installed correctly.
Air Flow Max. flow line Pressure drop (MPa) Max. air flow rate (m3/min (ANR)) Air flow rate (l /min (ANR)) Model Selection Select the model in accordance with the following procedure taking the inlet pressure and max. air flow into consideration. (Example) Inlet pressure: 0.6 MPa Max. air flow capacity: 5 m3/min (ANR) 1.
Max. air flow rate (m3/min (ANR)) JIS Symbol P . 14-20-55 Inlet pressure (MPa) Caution Be sure to read before handling.
Specifications 0.01 m (95% filtered particle diameter) Filtration of outlet air Max. 0.1 mg/m3 (ANR) (0.08 ppm) Note) Outlet air oil mist concentration (Prior to oil saturated 0.01 mg/m3 (ANR) or less, (0.008 ppm or less)) Note) With inlet air oil mist concentration of 30 mg/m3 (ANR) (24 ppm) Applicable Model Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080
/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2 x 3 x 60 = 2736g/h. 6 7 8 3 1 2 3 4 5 Dew Point Conversion Chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 -40 -30 -20 -10 -60 -50 -60 -50 -40 -30 -20 -10 0 10 20 30 Atmospheric
mounting screw (M3 x 0.5 x 10l ) Switch spacer Switch mounting nut Data 50 25 to 600 BQ-2 63 25 to 600 Please contact SMC regarding non-standard strokes.
MVGQ 10 16 20, 25 32 0.54 10% M3 CUX32-PS Grease pack (10 g): 1 pc. 1.23 10% M4 It is impossible to replace seals in bore size 10 mm. CC 2.55 10% M5 4.02 10% M6 2. Grease pack When maintenance requires only grease, use the following part numbers to order. Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1.
Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 RS H A Manufacture of Intermediate Stroke BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut RZQ Ordering Refer to standard part number and ordering on page 10-10-2.
Check the detecting position again and tighten the mounting screw to fix the auto switch definitely (the tightening torque of M3 screw should be about 50 to 70 N/cm). 5. Modification of the detecting position should be made following step #3. C76 C85 C95 Auto Switch Mounting Band Part No.
Dimensions 28 IN OUT 58(Max.60) 37 20 22 15 5 34 14 SMC 31 IN OUT 62 O-ring size 4 x 1.5W Holding screw M3 x 0.5 x 20 SMC P K U C S O H L 9 14-4-46 29 Compact Manifold Regulator/Series ARM10/11 Specific Product Precautions 1 Be sure to read before handling. Design & Selection Piping Warning Caution 1. Confirm the specifications.
Vertical mounting: 0 (None) Data NO Confirmation of sum of load ratio to the guide unit n 1 The moment load rate must be calculated in accordance with the above formula for all types, M1 to M3. As for Wmax and Mn, refer to the maximum load mass and allowable moment table in the next section.
Size: M3, M5 Basis, Thread: Rc (Metric thread, M3, M5), Port Size: M3 x 0.5, Option: None, Lock Nut: Round
Recommended tightening torque Thread size 0.61 to 0.63 Nm M3 0.73 to 0.75 Nm M4 Never use this product in locations where the explosion of dust is likely to occur or flammable or explosive gases are used. This can cause fire. 1.3 to 1.5 Nm M5 5. Do not touch the emitter directly with fingers or metalic tools.
Required ventilation rate [m3/min] Heat radiation amount [kW] Differential temp. of 3C Differential temp. of 6C Model between inside and between inside and outside of installation area outside of installation area 7. This product series are constant-temperature fluid circulating machines with built-in tanks.
Power cable Signal Cable Specifications Signal cable Terminal specifications Cable specifications Terminal block screw diameter Recommended crimped terminal 0.75 mm2 (AWG18) Shielded cable M3 Y-shape crimped terminal 1.25Y-3 Partially enlarged view A 174 Thermo-chiller Inverter Type HRSH Series Operation Display Panel List of Function The basic operation of this unit is controlled through