No.EX-OMU0020CN PROFINET SI EX245-SPN1 / Series EX245-DX1 / Series EX245-DY1 / Series EX245-EA2-1 EX245-EA2-2 / Series . 4 . 5 1. . 10 1.1. . 10 1.2. . 11 2. . 12 3. . 13 3.1. . 13 3.2. . 15 4. . 18 4.1. . 18 4.2. . 20 4.3. SIEMENS PLC . 23 5. . 35 5.1. . 35 5.2. PROFINET . 39 5.3. . 43 6. SI EX245-SPN1 . 44 6.1. . 44 6.2. . 45 6.3. . 46 6.4.
Flash Operating voltage 24 VDC +20%/-15%, Class 2 1 ON US2 [US3, US4 .. etc] is present (> approx. 22.8 VDC). Detected: < approx. 20.4 VDC Cancelled: > approx. 21.6 VDC 3 : If the US2 power supply is not present or below the dropout level, the SF LED will also flash and the error code "0x01F1" will be generated.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2015 SMC Corporation All Rights Reserved EX-OMS0018
g +15 g DIN +65 g -66No.PF-OMO0004CN-E 1 () 2()10024 551005009.5 221002003.8 3OUT 40()90% ON(OFF) 5 6 70()90% 8 9 10 ZS-33-D AWG26 1.00 mm +0.10 3.5 -0.25 -67No.PF-OMO0004CN-E A B C 1 V 1.04 V 5 V 4 mA 4.16 mA 20 mA PFMB7201 2 L/min 200 L/min -68No.PF-OMO0004CN-E -() [L/min] OUT ()( ) [kPa] IN 200kPa IN 400kPa [L/min] -69No.PF-OMO0004CN-E IN 3F.S.8cm IN OUT [%F.S.]
Safety Instructions Piping Connector Pin numbers (on the lead wire) Output for PF2A3 + Analogue (4 to 20 mA) type: PF2A5 -2Output for PF2W3 + Analogue (4 to 20 mA) type: PF2W5 -2Use the product within the specified operating pressure range and temperature range. Proof pressure is 1.0 MPa for air and 1.5 MPa for water. Connect the piping to the fittings.
Zero or more Output for PF2D3 + Analogue (4 to 20 mA) type: PF2D5 -2 Flow direction Sensor Monitor PF2D3 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Writing registers.3-13 3.11.3 Function code: 16 Writing multiple registers .3-15 3.12 Negative response . 3-16 3.13 Register map . 3-18 HRS400-A-46 DOC1003626 Contents 3.13.1 Circulating fluid discharge temperature . 3-19 3.13.2 Circulating fluid flow rate . 3-19 3.13.3 Circulating fluid discharge pressure . 3-19 3.13.4 Circulating fluid electrical conductivity . 3-19 3.13.5 Status flag . 3-20
Writing registers .3-14 3.11.3 Function code16 Writing multiple registers .3-15 3.12 Negative response . 3-16 3.13 Register Map . 3-18 HRL Series HRX-OM-W069 Contents 3.13.1 Circulating fluid discharge temperature . 3-19 3.13.2 Circulating fluid electrical conductivity . 3-19 3.13.3 Circulating fluid discharge pressur . 3-19 3.13.4 Circulating fluid flow rate . 3-19 3.13.5 Status flag . 3-20
3.13.6 Circulating fluid set temperature . 3-20 3.13.7 Operation instruction . 3-20 3.13.8 Data instruction . 3-21 Chapter 4 Communication alarm function . 4-1 4.1 COMMUNICATION ALARM OCCURS . 4-1 4.2 COMMUNICATION ALARM RESET . 4-2 4.3 SETTING METHOD . 4-2 HRLE Series HRX-OM-Z015 Chapter 1 Read before using Chapter 1 Read before using The communication of this product consists of contact
Tightening torque Bore size Socket Tightening torque[Nm] 40,50 13 (M8) 7.4 63 17 (M10) 20 80,100 19 (M12) 29 2 4 Tie rod tightening order. 18 3-2-2. Removal of seals 1) Rod seal Insert a precision screwdriver from the front of the cover to pull out the seal as shown in Fig. 7.
Operating environment . 20 5-4. Lubrication . 20 6. Maintenance . 20 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
System error Brown DC(+) Internal data error 12 to 24VDC + Black OUT Load Internal data error Blue DC() 6 Series ZSE30/ISE30 Dimensions 20 0.1 2-M3 x 0.5 Thread depth 4 Lead wire with connector 9.5 25 8 30 3.6 M5 x 0.8 MPa PRESSURE 20 0.1 10 SMC OUT Width across flats 12 SET 1.5 01: R 1/8 T1: NPT 1/8 With bracket 42.5 10 15 4.2 3 22 30 20 25 20 SMC 45 30 1.8 35 35 Panel mount 8 17.8 7.2
SOLENOID SPECIFICATIONS Adder Number 0 1 Required Amplifier VEA1 30, VEA131 vEA 250, 251 ,252 Control Range 0-750mA 0 1 A Coil Resistance 26]2 (68"F (20"C) ) 1312 (68"F (20'C)) PorYer Consumotion 15W Max. Current (68"F (20"C) ) 13W Max. Current (68"F (20'C)) Insulation Class H Max. TempeEture Rise 284'F (140"C) at Full Current Elec-trical Connection DIN Connector (h" PF) NVEF.
NO.ZK2-OM00801-B // ZK2-ZSV-A A 2 9 10 11 14 14 15 16 16 17 17 20 20 20 F0 22 F1 OUT1 23 F2 OUT2 25 F3 27 F4 28 F6 30 F11 31 F80 32 F81 33 F90 34 F96 36 F98 37 F99 39 40 B 43 44 45 51 52 52 -1NO.ZK2-OM00801-B (ISO/IEC)(JIS)1)2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems.
Discharge the cleaning fluid and rinse the cooling tower with water for 20 minutes or longer to get rid of the cleaning agent. Hose Circulation pump Water amount 20 to 30 L/min. Pressure 0.1 to 0.3MPa Tank (Barrel) c Procedure when the cooling tower is used. 1. Inject the detergent into the cooling tower and clean the tower for specified period of time. 2.
Do not modify the internal electrical wiring of the product. 12.2 Operation / Error signal output Operation mode signal (Contact output) Operation signal During operation: contact "close" Error signal During error: contact "close" Contact capacity Rated load voltage 240 VAC or less / 24 VDC or less Maximum load current 5A (resistance load) / 2A (inductive load) Minimum applicable load 20
GFCI 5. 6. 7. 13 1 13 R 13-2 IDFA6E-20-R 5A 30mA 13-3 1) 2) 3) 9.5mm M5 1.25mm 2 L N 6.5mm M3 1.25mm 2 6-3 14-3 13 2 14 T 14 T T 14-2, 14-3 14-1 1. 2. 3. GFCI 4. 5. GFCI 6. 7. 8. 9.
No.PS-OMU0005CN-C // ZSE20B(F) ISE20B 2 8 10 11 15 15 17 20 [] 23 24 3 25 27 29 29 29 F0 31 F1 OUT1 32 F1 OUT2 35 F3 37 F4 38 F5 FUNC 40 F6 42 F10 43 F11 49 F80 50 F81 51 F82 53 F90 54 F96 56 F97 57 F98 59 F99 61 62 66 66 67 76 76 79 -1No.PS-OMU0005CN-C (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO
-2No.PS-OMV0008CN-E / *3) 1 1.5 3) 1 1 () [] -3No.PS-OMV0008CN-E () () () () -4No.PS-OMV0008CN-E () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) (ISE7G-T-ZS-48-A) N G -5No.PS-OMV0008CN-E Al2O3(96)C3604+FKM () O 1 /min 16MPa () * FG (35 N () ,() *() 6 33 -6No.PS-OMV0008CN-E () () 20 m DC(-)() * () () CE -5~70-5~50(5 ) (FKM) Al2O3()C3604()( ) -7No.PS-OMV0008CN-E
F 0 Unit selection 1 [ PA] kPa Connector Switch point Hysteresis Display colour ISA3-F: [ 20], ISA3-G: [ 50], ISA3-H: [ 50] OUT1 setting Bracket mounting hole ISA3-F: [ 3], ISA3-G: [ 20], ISA3-H: [ 20] F 1 [ SoG] Green when ON, Orange when OFF out2: [ Ewin] OUT port side pressure detection window comparator mode Output mode Thank you for purchasing an SMC ISA3 series Gap Checker.