(Refer to "Air Fittings and Tubing" CAT.E501-B.) Note 2) On standard products all brass parts are electroless nickel plated. (Suitable for copper free applications.) Flow Rate and Effective Area VR1220F VR1210F Model Metric size 10 8 6 8 6 4 3.2 Applicable tubing O.D.

LED LED SI LED 2 SI LINK (X1) Port1(X1) ACT (X1) Port1(X1) LINK (X2) Port2(X2) ACT (X2) Port2(X2) FO1(X1) Port1(X1) FO2(X2) Port2(X2) SF BF US1 / US2 / US3 US4 . 6-3 SI LED 6.4.1. LINK LED . 6-2 LINK LED LINK 1/2(XF1/2)Ethernet 1/2(XF1/2)Ethernet 6.4.2. ACT LED . 6-3 ACT LED ACT / 1/2(XF1/2)Ethernet 1/2(XF1/2)Ethernet 47 No.EX-OMU0020CN 6.4.3.

Station number 20 (No.2) 2 (No.6) 1 (No.7) 40 (No.1) 8 (No.4) 4 (No.5) 10 (No.3) SW2 OFF 1 OFF OFF OFF OFF OFF OFF ON 2 3 4 OFF OFF OFF OFF OFF ON OFF 6 5 4 3 2 1 ON ON OFF OFF OFF OFF OFF ON ON : Switch No.5 and No.6 are unused. (Turn them OFF.) OFF OFF OFF OFF ON OFF OFF : : : : : : : : HOLD/CLR setting (Switch No.1) The setting is as follows.

x P (Rc, NPT, G) NA AL F Width across flats B1 H1 2 x NN Standard port Relief port M5 x 0.8 H2 I Relief port D C B 4 x LD LH MM 2 x 4 3.2 N X Y N X Y S + Stroke LX LS + Stroke Z LZ ZZ + Stroke (mm) AL LH LS LZ MM G NA N LX LD D C A B 16 13 13 13 8 F Bore size K H1 H 8 6 6 5 H2 I 41 32 32 26 B2 54 47 47 40 B1 Stroke range 50 45 45 41 M10 x 1.25 M8 x 1.25 30 40 32 25 20 5.5 5.5 5 200 to 1000

N L1 L2 Weight (g) Port B Min. port size L3 L4 L5 L6 P Q1 Q2 MA MB FA FB KM11-03-09-6 KM11-03-09-10 KM11-07-11-6 KM11-07-11-10 KM11-09-13-6 KM11-09-13-10 6 65 10 40 22 5 32 5 16 18 29.5 19.5 27 10.6 12 16 18.5 6 10 86 6 77.8 10 104 6 85 10 115 61.5 30 48 32 10 19.5 31.5 21.5 30.5 13.2 13 17 21 7 1 4 3 8 73.5 44 52.8 44 12.7 23.7 37.7 25 35.9 15.2 15 18.5 22 9.5 5 16 1 2 83 62 Metric Applicable

SW power 24 VDC 23 VDC Sensor Bit: 7 0 Byte 3 Offset 1 Tie-rod (2 pcs.) Accessory 3 4 7 2 Bit No. 0 2 4 6 0 0 4 6 Input block SI unit Output No. Solenoid on side A 2 4 6 16 28 30 0 8 No. Description Function To obtain the operation manual about this product and control unit, please refer to the SMC website (URL https://www.smcworld.com) or contact SMC directly.

OUT (2) 1 Coil insulation Body material and coil insulation type Symbol Body material Seal material (1) IN Nil A B PPS NBR FKM EPDM Class B Voltage 5 6 24 VDC 12 VDC Symbol Size Series Port connection type G Grommet Coil type P7 P10 C4 C6 C8 C10 30 40 P7 quick fastener P10 quick fastener One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 10 Power-saving

) Connections 1/2, 3/4 inch face seal, 1/2, 3/4 inch tube weld 3.

L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover

13 20 Metric 6 12 19 Inch Integral fittings 1/4" 1/2" 3/4" Tubing size Tube extensions Metric 6 6 Inch 1/4" 3/8" 1 Regulator for Chemical Liquids Series LVR How to Order 07 LVR 2 Z 0 Integral ttings Body class Pilot port thread type Symbol Type Nil Rc N NPT Symbol Body class 2 2 4 4 5 5 Applicable tubing size Fitting type LQ1 Metric size Inch size Symbol Model V LQ1 Z LQ3 Symbol Applicable

) ) ) ) PE 1) 1) 1) 1) 2) 2) 2) 2) PE PE (AMC ) 3 3 3 3 (A,B) (N.C.)N.O.3 3 B (CYL.1) A (CYL. 2) N.C.

2 !2 !3 !3 !4 !4 !5 !5 M5 port M5 port y y u u !7 !7 q w e r t q w e r t o o !0 !0 !1 !1 i i !4 !4 !2 !2 !3 !3 !6 !6 Component Parts Description Material Description Material No.

industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -(1:) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4.2 2 VFR5000-OMN0001 / / / / 1 1 3) 3) 1 1 () 3 VFR5000-OMN0001 VFR5000 Series 5 / 1 DC 3 () 0.1 2 C-R () C-R DC 3% AC 20% ( ) () () 3 3 EXH (VVFS5000-R-04-1,2) ( ) () 3 4 No.VFR5000-OMN0001 VFR5000 Series 5 / (SSR )AC 1) (C-R ) OFF 2)() 1 -10 1 1) M5 1/6~1/4 1

(Q + Stroke) Q + Stroke CY1F 4 x MM thread depth ML (LL) LA 6 x YA recessed area Note 2) XAH7 PA Adjustment bolt Max. approx.

Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Power supply is 24 VDC Internal voltage drop in switch is 4 V. Example: Load impedance is 3 k.

Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Power supply is 24 VDC Internal voltage drop in switch is 4 V. Example: Load impedance is 3 k.

Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included

Flow Characteristics With DIN terminal block With terminal block Port size Flow characteristics 2 3 (A R) b Cv C [dm 3/(sbar)] 1 2 (P A) b Cv C [dm 3/(sbar)] 26 38 0.38 0.30 7.0 9.8 27 38 0.37 0.32 7.4 9.8 27 40 0.36 0.22 7.3 9.8 25 40 0.37 0.20 6.8 9.6 2 1 (A P) b Cv C [dm 3/(sbar)] 3 2 (R A) b Cv C [dm 3/(sbar)] 1/2 3/4 Port size Effective area (mm2) 2 3 (A R) 1 2 (P A) 235