Max Operating Pressure: 7 MPa, Construction: Element Upward Removal, Threaded, Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: Differential Pressure Indicator, Relief Valve: None, Fluid: Petroleum, Element: Paper, Filtration: 10μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 14 MPa, Construction: Element Upward Removal, Threaded, Port Size: 3/8 Threaded, Pressure Indicator: Differential Pressure Indicator, Relief Valve: None, Fluid: Petroleum, Element: Paper, Filtration: 10μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 14 MPa, Construction: Element Upward Removal, Threaded, Port Size: 3/8 Threaded, Pressure Indicator: Differential Pressure Indicator, Relief Valve: None, Fluid: Petroleum, Element: Paper, Filtration: 20μm, Fluid Direction: -, Made to Order: -
Types: Nozzle, Nozzle Shape: Standard, Features: Standard / Quiet, Nozzle Connection Port Type: Male Thread, Nozzle Material: Brass, Maximum Operating Pressure(MPa): 1, Nozzle Diameter(φ): 1.1 × 8, Connector size: R1/4
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 225/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 225/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 260/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 260/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
, 200, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, 5 port solenoid valve, 4/5 PORT SOLENOID VALVE, 110 lb
Description Decimal Common Format "Data-INT" "Data-SINT" Input MIN. 1 word MIN. 2 byte MAX.110 words MAX.220 byte Output MIN. 1 word MIN. 2 byte MAX.110 words MAX.220 byte When configuration assembly fundtion is not used: Set to "0".
Appendix G: EX245-FPS Timing Values . 110 24. Appendix H: Cybersecurity . 111 3 No.EX##-OMY0004 1. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".