SMC Corporation of America
Elite Part Number Search
Search Results "JSY5A03T-5NZ-H"

Micromist separator AMD900, 1000, 901 Model Connect (Flange) 2B 2B/3B/4B 400 A 280 B 6B C 550 D 150 E 270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 Mounting Caution q Verify the direction of the flow of the compressed air and the "e" mark that indicates the inlet of the product before connecting.

Cylinder EA Absorber model EB EC ED EF EY S T EH EI h i TT REA ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 4.5 3 MAX. 16.5 RB1412 120 107 30 25 16 93 73.2 15 38 49 5.5 6 MAX. 20 REC RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 5.5 6 MAX. 25 RHC Side Support MTS CC Side support A Side support B (mm) H G F J E Cylinder D Part No.

48 24.5 10 D 2-5.5 through 4-9 counter bore depth 7 2-Rc 1/8 (port size) 36 K C X L 8 36 47 14 20 50 + Stroke 55 + Stroke 5 2-P (port size) 32 to 100 H with effective thread depth C F F 4-N through hole 8-O counter bore Approx.

D-A9, F9 Rod end nut C1 X L1 Rod end male thread (mm) Bore size (mm) C1 X H1 L1 32 20.5 23.5 28.5 M14 x 1.5 40 20.5 23.5 28.5 M14 x 1.5 50 26 28.5 33.5 M18 x 1.5 (mm) Without auto switch With auto switch A B A B U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43

S: Upper space 90, Lower space 180 6 Compact Rotary Actuator Rack-and-Pinion Type Series CRQ2 TF effective depth TL Sizes 20, 30, 40 TA TB 45 BE CA CA BU 8-JJ (opposite side 4 places) 2-J through (opposite side JA counter bore depth JB) BD B With double shaft DD W D I K Auto switches b (10) Max. 2-Rc1/8 (port size) H F (US) M (UW) CB Q BC N BB BA BA G D A (AU) Max S L TF effective depth

31% Ove Ove O 31% 31% 31% CY1F MY2H CY1H CY1F Height mm CY1H 10 15 25 Series CY1F CY1H 28 34 46 46 63 39.5 Overall length mm h i h h t weight ht weight t weight ht ht Series 240 350 310 CY1F CY1H MY2H 198 225 205 294 260 50% reduction in weight 50% reduction in weight 50% reduction in weight 50% reduction in weight For 100mm stroke cylinder Weight kg Guide un Base gasket 10 15 25 Series

Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.

T PW 2-Rc P (plug) Rc 1/8 unlocking port Unlocks when pressurized GC GA XAH7 depth XL 2-Rc P PB A + Stroke E B + Stroke FA FB C + Stroke PA + Stroke GB Q G J K IE S XAH7 depth XL (mm) MLGPM, MLGPL common dimensions Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB GC H HA IA IB IC ID IE 14 11 100 44 16 12 44 54 10 120 M6 34 52 14 4 14 40 25, 50, 75 100, 125, 150, 175 200, 250, 300,

Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.

(mm) Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5 15 178 195 221 16 16 16 12 15 15 44 50 56

P P P Lock position Z80 P P H R Rear lock Front lock Y59A Y69A P p P Manual release Y7PV Y7P P P p N L Non-locking type Locking type Y59B Y69B P p P Solid state switch Y7NW Y7NWV P P p Y7PW Y7PWV P P p Y7BW Y7BWV P P p Y7BA P p Lead wire symbols 0.5m . Nil (Example) Y69B 3m . L Y69BL 5m . Z Y69BZ Solid state switches marked with a "p" are produced upon receipt of order.

in-line mount Z axis motor side mount Axis type Y Y axis Ball screw specifications Stroke(mm) Rolled ball screw(mm) 16, 32 lead Symbol J 100 150 10 15 Motor specifications 950 1000 95 A0 Motor specifications Mitsubisi Electric Corporation, Yaskawa Electric Corporation, OMRON Corporation Brake 400W without brake Symbol G *Standard strokes are available in 50 mm increments. 400W with brake H

Dimensions/Socket (S) Male thread type A2 A1 T D H L1 L2 (mm) A1 A2 Effective area mm L2 Body size H Width across flats T Connection male thread Minimum bore Model D Weight g When When L1 connected connected KKH3S-01MS R1/8 33.5 20.4 20.4 6 36 18.2 14 1/8 40 37.5 KKH3S-02MS R1/4 31.5 19.5 21.1 9 34 KKH4S-01MS R1/8 54.1 50.4 46.4 48.8 22.9 6 50.1 KKH4S-02MS R1/4 54.7 51 19 45 45.4 38.9 9 48.7

Lock pin Allows fine stroke control ame as d on one h sides Features 2 Series MY1 Model Selection The following are steps for selection of the series MY1 best suited to your application.

Up to 36% reduction MY3A With rubber bumper Height (H) MY1B MY3A/3B MY3B With air cushion Height(H) (mm) Series 16 25 40 63 MY3A MY3B MY1B 27 37 54 84 MY1B With air cushion 37 54 84 116 Up to 53% reduction Max. 53% Weight Overall length(Z+Stroke) Z dimension Weight (kg) (mm) Series 16 25 40 63 Series 16 25 40 63 MY3A MY3B MY1B 0.34 0.87 2.95 8.26 MY3A MY3B MY1B 110 150 240 320 0.35 0.97

K ( across flats) H (With locking) 80 9 6.5 10 18 50 YB-03 32, 40 120 11 6.5 12 22 60 YB-05 50, 63 d2 d1 L UT C UA (mm) UA C d1 d2 H k L UT Weight (g) 25 Part No.

S Number of auto/ proximity switches Guide type Direct acting guide H 1 2 1 pc. 2 pcs. When using both auto and proximity switches, list the proximity switch part number after the auto switch part number. Example) F9N1G2 AC servomotor Motor type A 6 6 pcs.