Blue .012 F-2815-121-NORYL Green .014 F-2815-141-NORYL Orange .016 F-2815-161-NORYL Grey .017 F-2815-171-NORYL Brown .019 F-2815-191-NORYL Red .020 F-2815-201-NORYL Dk.
Blue .012 F-2815-121-NORYL Green .014 F-2815-141-NORYL Orange .016 F-2815-161-NORYL Grey .017 F-2815-171-NORYL Brown .019 F-2815-191-NORYL Red .020 F-2815-201-NORYL Dk.
override 34.7 [41.7] M5 x 0.8 (A, B port) 2-1.8 (For manifold mounting) (Light/Surge voltage suppressor) 28 [35] + 22.1 54.4 [56.6] 2 13.5 12.6 15 R P R (Bracket) 15 11 10 1.2 (PE port) 22.1 7 7 15 M5 x 0.8 (P, R port) M8 connector (WO): SYJ3120-WO-M3 (-F) L plug connector (L) : SYJ3120-L-M3 (-F) M plug connector (M): SYJ3120-M-M3 (-F) (2) Approx. 300 (Lead wire length) 28 [35] 12.6 32.5
Features 5 Air Dryer Variations Series IDF E/F/D Standard inlet air temperature type Rated inlet air temperature: 95, 104F (35, 40C) [Max. inlet air temperature: 122F (50C), 140F (60C) (F and FS type only)] Refer to SMC website for details.
Head Flange: CG3GN Bore size Stroke With rubber bumper Width across flats KA GA GB 4 x FD 8 x J 2 x P F R0.5 H1 0 E 0.05 MM D FX 0.15 0 E 0.05 I B C Corner of the cover (20 to 63) H A AL Width across flats B1 Width across flats NA F FT C FX 0.15 S + Stroke ZZ + Stroke B End boss is machined on the flange for E.
FC Mounting hole B 0 0.3 A F NA FT NB FX FZ H S + Stroke F Z + Stroke Refer to page 8 for details of the mounting nut.
Displacement of Section A when force acts on Section F Displacement of Section A when force acts on Section F F A F Guide central axis (1 axis type) F For the double axis type, this is the cylinders central axis.
EX600-DX#D/E/F (5 byte) Byte Bit Parameter Setting value 0..3 Unit No. 0..8 0 4..7 Parameter type 1 EX600-DX#D: 05 (Hex) EX600-DX#E: 14 (Hex) EX600-DX#F: 16 (Hex) 1 0..7 Unit ID Unit parameter 0 Monitor short circuit (power) 0: disable, 1: enable 1 Reserved 0 2 Inrush current filter 0: disable, 1: enable 2 3 Reserved 0 4..5 Input filtering time 0: 0.1 ms, 1: 1 ms, 2: 10 ms, 3: 20 ms 6..7
G1, Symbol N: NPT1) Tank port size Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4) Supply side pressure range MPa 0.2 to 0.5 Automatic water fill function (Standard) Supply side water temp. range oC 5 to 35 Automatic water fill port size Rc1/2 (Symbol F: G1/2, Symbol N: NPT1/2) Over flow port size Rc1 (Symbol F: G1, Symbol N: NPT1) Fluid contact part material Metal Stainless steel, Copper (Brazing
Operating pressure: 0.4 MPa Model Selection Illustration When gripping a workpiece as in the figure to the left and with the following definitions, F: Gripping force (N) : Coefficient of friction between attachments and workpiece m: Workpiece mass (kg) g: Gravitational acceleration (= 9.8 m/s2) mg: Workpiece weight (N) F F the conditions under which the workpiece will not drop are mg F F
Eliminate the unnecessary parts. 1.10-13 Series CS1 Front Flange/CS1F Lube (CS1F), Non-lube (CS1FN), AIr-hydro (CS1FH) Long stroke With auto switch/CDS1F (mm) Stroke range (mm) W/o rod boot With rod boot Style Bore (mm) J FT FX FD S AL B E F FA KA M MM H A D EA FY FZ G K N P B C h ZZ e f l ZZ1 125 140 160 180 200 250 300 115 1/2 M30 X 1.5 145 75 40 145 190 100 230 M14 X 1.5 110 238 133 261
Operating pressure: 0.4 MPa Model Selection Illustration When gripping a workpiece as in the figure to the left and with the following definitions, F: Gripping force (N) : Coefficient of friction between attachments and workpiece m: Workpiece mass (kg) g: Gravitational acceleration (= 9.8 m/s2) mg: Workpiece weight (N) F F the conditions under which the workpiece will not drop are mg F F
mg F F Gripping force at least 10 to 20 times the work piece weight The "10 to 20 times or more of the work piece weight" recommended by SMC is calculated with the safety margin of a = 4, which allows for impacts that occur during normal transportation, etc. 2F mg Number of fingers and therefore, mg F 2 x With "a" as the safety margin, F is determined as follows: mg F = x a 2 x When
F = one finger thrust.
1.6 (PE port) 1/8 (P, R1, R2 port) B A 17 One-touch fitting (A, B port) (4.9) 36 Applicable tubing O.D.: 6, 1/4" : 8, 5/16" (3.6) L plug connector (L): SYJ7120-L-01 (-F) M plug connector (M): SYJ7120-M-01 (-F) M8 connector (W0): SYJ7120-W0-01 (-F) DIN terminal (D): SYJ7120-D-01 (-F) Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 65 31.5 [38.5] 101 Max. 10 57.5 16.1 46.2 31.1
NA S + Stroke F H WH B ZZ + Stroke (mm) A B C D E F GA GB H H1 H2 I Bore size (mm) Stroke range (mm) Effective thread length 26 8 5 44 47.5 53.5 16 14.5 10 18 40.5 32 15.5 200 to 700 20 31 8 6 48 49.5 56.5 16 18 12 22 45.5 36 19.5 200 to 700 25 38 9 6 51 51.5 55 19 18 12 22 51.5 44 19.5 200 to 1000 32 47 11 8 54.5 51.5 56 21 20.5 16 24 61.5 53 21 200 to 1000 40 N NE NA NB NF ND NN P S WH
Function selection mode In measurement mode, press the button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 Measurement mode Power is supplied. Press the button between 3 and 5 seconds.
Function selection mode In measurement mode, press the button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 Measurement mode Power is supplied. Press the button between 3 and 5 seconds.
Function selection mode In measurement mode, press the button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 Measurement mode Power is supplied. Press the button between 3 and 5 seconds.
ON: Green OFF: Red [F 2] Setting of OUT2 Same setting as [F 1] OUT1. At the output mode, Error detection mode can be selected. Display color is linked to the setting of OUT1, and can not be selected.