Size: 1 [ø7], Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: B (FKM Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 8A (1/4), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Bracket: B (Bracket)
Size: ø10, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: FKM, Thread: Rc, Port Size: 1/4, Voltage: 24VDC, Lead Wire: Grommet Terminal w/Light & Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Bracket: Bracket, X200: -, CE Compliant: -
Size: ø10, Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/4, Voltage: 24VDC, Lead Wire: Grommet, Manual Override: Non-locking Push Style, Bracket: Bracket, X200: -, CE Compliant: -
Size: ø10, Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/4, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Bracket: Bracket, X200: -, CE Compliant: -
Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Open, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference
Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference
Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference
Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference
Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference
Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: FPM seal, Thread: Rc(PT), Port Size: 1/4, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Bracket: None, CE Compliant: CE Compliant
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Valve Stations: 1 Station, Port Size: 03 (3/8), Thread: N (NPT), SI Unit: Q (DeviceNetâ„¢), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A)
Valve Stations: 3 Stations, Port Size: 03 (3/8), Thread: T (NPT/NPTF), SI Unit: WS (Wireless Remote Unit), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)
Valve Stations: 4 Stations, Port Size: 03 (3/8), Thread: F (G), SI Unit: N (PROFIBUS DP), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A)
Valve Stations: 3 Stations, Port Size: N11 (ø3/8" One-touch Fitting), Thread: N (NPT), SI Unit: WE (EtherNet/IPâ„¢, Compatible Wireless Base Unit), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)
Valve Stations: 6 Stations, Port Size: 02 (1/4), Thread: T (NPT/NPTF), SI Unit: V (CC-Link), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A)
Valve Stations: 3 Stations, Port Size: C8 (ø8 One-touch Fitting), Thread: Rc, SI Unit: Q (DeviceNetâ„¢), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)
Valve Stations: 3 Stations, Port Size: 03 (3/8), Thread: T (NPT/NPTF), SI Unit: Q (DeviceNetâ„¢), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A)
Valve Stations: 4 Stations, Port Size: 03 (3/8), Thread: T (NPT/NPTF), SI Unit: Q (DeviceNetâ„¢), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A)