SMC Corporation of America
Elite Part Number Search
Search Results "VV5FA5-21-031"

Dimensions B A D C M (mm) Stopper bolt Stroke adjustable range (mm) 5 Applicable size B A C D M Model Lock nut MXW-A812 21 MXW8 8 M5 x 0.5 2.5 6 MXW-A812-X11 15 31 MXW-A1212 5 23.5 MXW12 8 M5 x 0.8 2.5 6 Avoid operating within 1 mm. The effectiveness of the shock absorber and urethane damper will not be brought into full play, and could be adversely affected.

1, @2 and @6 each. 12 MXY12-PS 8-9-11 11 Series MXY Dimensions 2-M5 x 0.8 Piping port J + Stroke Same in case of the type of centralized piping on one side without switch rail ( ) JH Piping port (Plug: M-5P) 2-M5 x 0.8 (Plug: M-5P) 2-M5 x 0.8 Piping port FL 21 21 FH 2-M thread depth MM +0.03 0 Width across flats MB (lock plate fixing bolt) R 4-M thread depth MM PR RL PR +0.03 0 MA (Stroke

(This is effective against upward starting delays and for conservation of air.) 21 Series CYP Specific Product Precautions 2 Be sure to read before handling. Cushion Effect (Sine Cushion) and Stroke Adjustment Particulate Generation Characteristics Caution Caution 1.

Load 21 Series CYP Auto Switch Precautions 2 Mounting & Adjustment Wiring Warning Warning 1. Do not drop or bump. Do not drop, bump or apply excessive impacts (300m/s or more for reed switches and 1000m/s or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2.

Load 21 Series CYP Auto Switch Precautions 2 Mounting & Adjustment Wiring Warning Warning 1. Do not drop or bump. Do not drop, bump or apply excessive impacts (300m/s or more for reed switches and 1000m/s or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2.

9200-www.stevenengineering.com VT 20.5 19 3 2 VP 1 9.5 6.5 5.5 4.5 VG 12.3 10 10 25 VP M3 x 0.5 3 (EXH) port M3 x 0.5 1 (SUP) port M3 x 0.5 2 (OUT) port S070 VQ VKF S070B-C-M3 Plug lead type VQZ VZ VS 0.1 W with power saving circuit 150 (Lead wire AWG#26) 3.5 27 6 VFN 26 23.5 20.5 3 9.5 28.5 3.5 4-11-5 6 Series S070 Dimensions Base mounted with screws S070B-G-M5 Grommet type 16.5 3 7 15 21

L dimension 19 248 18 235.5 17 223 16 210.5 15 198 14 185.5 13 173 12 160.5 11 148 No. 20 260.5 L dimension 30 385.5 29 373 28 360.5 27 348 26 335.5 25 323 24 310.5 23 298 22 285.5 21 273 No. Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

Note 12) Consult P/A for detailed dimensions and available attachments and options. 21

4.5 11 66 + Stroke 27.5 93.5 + Stroke 10, 16, 20, 25 Mounting nut Rod end nut G1 G2 NN 2-P I NA D J N2 N1 MM A F F S + Stroke H ZZ + Stroke (mm) P Bore size (mm) MM A NN D F G1 G2 S ZZ I H J N1 N2 NA TN TF 10 15 M12 x 1 4 M5 x 0.8 8 15 6 M4 x 0.7 65 101 18.5 28 16 11 20 16 16 15 M14 x 1 5 M5 x 0.8 10 15 6 M5 x 0.8 74 114 22 30 22 12 21 19.5 20 18 M20 x 1.5 8 Rc1/8 13 NPT1/8 25 G1/8

#4) SMTS20, #3 7 Precision Cylinder Series MTS Dimensions/25 MTS25 Basic type 12 10 53.5 51.5 2-cushion needle Width across flats 11 7.5 6 Rod cross section 7 6 2-M5 x 0.8 (port size) 28 0.2 16.5 15 M6 x 1.0 4.5 4-4.5 through 2 x 4-7.5, counter bore depth 4.5 (opposite side also) 22 0.2 4-M5 x 0.8 Effective length 8 6.5H7 +0.015 0 13h7 0 0.018 30 0.2 30 0.2 40 38 31 32 57.5 109 + Stroke 21

A + Stroke DL LL DM MO HR W 32 45 25 15 22 15 33.5 DM With front lock 40 52.5 29 21 26 19 38.5 50 59 29.5 21 24 19 45 63 64 28.5 21 25 19 50 63 cylinder tube configuration Q F A + Stroke B + Stroke Rod end male threads (mm) With rod end male threads H1 Bore size (mm) L1 C1 X H1 32 20.5 23.5 M14 x 1.5 28.5 40 20.5 23.5 M14 x 1.5 28.5 50 26 28.5 M18 x 1.5 33.5 C1 63 26 28.5 M18 x 1.5 33.5 X

Applicable auto switches/For detailed auto switch specifications, refer to page 17 through 21. Lead wire length (m) 0.5 (Nil) 3 (L) 5 (Z) Auto switch part no.

BIT 4 Stp-No.bit3 (7) 20 Step designation BIT 5 Stp-No.bit4 (20) 8 BIT 6 Stp-No.bit5 (8) 21 BIT 7 Stp-No.bit6 (21) 9 Stp-No.bit7 (9) 22 SET-ON 10 Temporarily stops the program run by means of the ON input. (3) Temporary stop HOLD READY 23 BUSY < 2 > 11 (16) Emergency stop (nonlogical input) Performs an emergency stop when ON input stops.

Bolt used Max. tightening torqueN.m{kgf.cm} l mm Model MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 10.5 12.5 16 21 26 32 1.2{12.2} 1.2{12.2} 2.8{28.6} 5.7{58.1} 5.7{58.1} 10{100} M3 x 0.5 M3 x 0.5 M4 x 0.7 M5 x 0.8 M5 x 0.8 M6 x 1 3. Top body tapped A hand can be caught by an adjuster option.

Product Features .pages 158-159 Q Q MXP Series Q How to Order .page 160 Q Specifications .page 161 Q Table Accuracy .page 162 Q How to Select .pages 163-164 Q Table Deflection .page 165 Q Construction/ Parts List, Seal Kits .page 166 Q Dimensional Drawings.pages 167-170 Q Auto Switch Specifications and Mounting.pages 171 Q Please see safety instructions on pages 20-21

hexagon socket head plug. 7 Mechanically Jointed Rodless Cylinder High Precision Guide Type Series MY2H Stroke adjusting unit Low load shock absorber MY2HT Bore size Stroke L G (Shock absorber stroke) T S TT E SD EY EA EC Stroke adjusting unit Shock absorber FA EB W Applicable cylinder MY2HT16 MY2HT25 MY2HT40 Shock absorber model RB1007 RB1412 RB2015 E 14.4 19.7 29.1 EA 7 10.7 15.1 EB 21

MXW25 MXW20 0.08 Table deflection quantity mm Table deflection quantity mm Table deflection quantity mm MXW25 MXW20 0.02 0.02 0.06 0.04 0.01 0.01 0.02 0 0 0 300 200 100 400 500 100 200 300 400 600 500 100 200 300 400 600 Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf 142 Long Stroke Slide Table MXW Series Construction / Parts List Packing List 5 3 4 6 17 18 15 2 1 21

(301 0.s9 t22.61 0.67 (17) 0.53 0.04 (1) o.22 o.24 (6) 0.83 (21) 0.61 (15.41 3.17 2.41 0.31 (8) 0.55 13.9 Millimeters in Parentheses DIRECTIONAL AIR VALVE MANIFOLD ASSEMBLY SERIES NVF 110 Manifold gaskets: W100-3-t (2-sta.)

Bore size (mm) 32, 40 50, 63 Stroke range (mm) 21 to 99 31 to 99 Stroke range Part number: RLQB32-47-B A special tube is manufactured for a 47 mm stroke.

Power Consumption (0.5W) Interchangeable with the NVJ and NVZ Vacuum Applicable Base Mounted/Body Ported Configurations P R O D U C T S Q Q Q Table of Contents Q Q Q Q Features & Benefits .pages 4-5 Q Preferred Option Program.page 7 Q Specifications.page 9 Q SYJ300 .pages 10-12 SYJ500 .pages 13-15 SYJ700 .pages 16-18 Q Q How To Order .page 19 Q SYJ300 .pages 20-21