Screw torque (Nm) depth (mm) MHZJ2-10 M3 x 0.5 0.9 6 MHZJ2-16 M4x0.7 1.6 4.5 MHZJ2-20 M5 x 0.8 3.3 8 MHZJ2-25 M6x1 5.9 10 Max. tightening torque (Nm) Maximum screw-in Model No. Screw depth (mm) MHZJ2-10 M3 x 0.5 0.69 5 MHZJ2-16 M4x0.7 2.1 8 MHZJ2-20 M5 x 0.8 4.3 10 MHZJ2-25 M6x1 7.3 12 Max. tightening Model No.
Hexagon socket Head cap screws M5x10 Positioning pin3x6 ISO9409-1-31.5-4-M5 Compliant Adapter plate. O ring5x3x1 For closing the finger(S) Speed controller JAS-LEA04-M5 For opening the finger (O) Speed controller JAS-LEB04-M5 Hexagon socket head cap screw M6x10 Hexagon socket head cap screwM4x20 Positioning pin5x10 Positioning pin6x10 ISO9409-1-50-4-M6 Compliant Mounting flange. 5 - 3.
Standard part number X1 Clean room specifications Specifications Non-grease specifications Cleanliness Bleed port Class 10 With M5 fitting (applicable tube O.D. 6) Manifold Specifications (except type IR2120 and series IR3000) 6 IR1000/2000: M5 fitting (applicable tube O.D. 6) IR3000: Rc(PT) 1/2 female thread EXH port Grease Teflon grease 2 to 8 station manifold type regulators.
g (including 0.6 m-long lead wire) R 1/8, M5 x 0.8, NPTF 1/8, M5 x 0.8 Port size R 1/8, M5 x 0.8 NPTF 1/8, M5 x 0.8 ZX ejector mounted type: M5 x 0.8 Enclosure IP40 Note 1) Instant pressure supply of 0.5 MPa has no influence on the switch.
: M5 x 0.8 0XY: M6 x 1.0 771
40 J (5) Drain guide 1/4 AFM30/40 Float type auto-drain (N.C.) (4) Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right Left AFM20 to 40 N (1) Drain cock with barb fitting: 6 x 4 nylon tubing Float type auto-drain (N.O.) (4) W F (2) AFM30/40 D AFM30/40 Note 1) Drain guide is NPT 1/4 (applicable to AFM30 and 40), and the exhaust port for auto-drain comes
Micro Mist Separator Series AFD20/30/40 How to Order 03 BD F 30 2R AFD Option Symbol 2 6 8 C J R Description Applicable model Micro mist separator Accessory AFD20 to 40 AFD20 to 40 AFD30/40 AFD20 AFD30/40 AFD20 to 40 Metal bowl Port size F.R.L. Description With bracket Float type auto-drain (N.C.) Float type auto-drain (N.O.)
A One-touch fitting for 12 is attached to each port.
Table. 11-1 Length the EX245 series module n 0 1 2 3 4 5 6 7 8 L 113.6 167.6 221.6 275.6 329.6 383.6 437.6 491.6 545.6 Formulas: L = 54n + 113.6 (max. 8 modules) (Dimensions in mm) -57No.EX##-OMU0020-A 12. Troubleshooting 12.1. EX245-SPN1/SPN2 Table. 12-1 Troubleshooting for bus communication No. Problem Possible cause Remedy 1 LINK indicator is OFF.
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Incorrect power supply Supply the correct voltage of 12 to 24 VDC 10%. Check the wiring to the power supply.
Incorrect operation of the internal data of the Pressure switch (Er0, Er4, Er6, Er7, Er8, Er9) System error (Er0, Er4, Er6, Er7, Er8 or Er9) is displayed. (2) Check that the power supply voltage is within the range 12 to 24 VDC 10%. (2) Supply a correct voltage of 12 to 24 VDC 10%.
MPa POWER LIGHT MPa POWER LIGHT 14-12-6 7 Compact Manometer Series PPA Dimensions Connecting tube port 40 20 Accessory One-touch fitting F.R.L.
Note) Dimension X includes the One-touch fittng IC 4 6 1/4" 123 124 126 VBA VE (Front) (Back) VY1 G 20 Option/Case holder 5 Fitting port diameter M5 x 0.8 Thread depth 5 PPA 44 6.8 9.2 4.5 AL 2 SMC 15 25 18 2-(R) 4.5 120 29 14-12-7 8 Series PPA Error Correction Maintenance Span calibration method When errors occur, they should be corrected as shown below.
Power supply connector POWER Connector (e-con) IZS41, IZS42 7 8 12 13 9 1 2 3 4 5 10 11 14 6 Operation NO.
M5 x 10 DIN913-45H VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 2 8 VT G 1/4 DIN/ISO228/1 M5 Drive flange face VP VG 19.5 5.5 Solenoid valve flange face VP O-ring 16 x 2 1.5 3 S070 VQ VKF The solenoid valve can be attached with 2 mounting bolts.
at 40 mA) Current leakage 100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
EX500-DXPB Install the product using 2 M5 screws x 20 mm or longer with a head 9 to 11. 51 No.EX-OMS0014-A Wiring EX500-DXPA Branch wiring Connect the branch cable to the branch connector (IN/OUT). Refer to page 12 for wiring. Sensor wiring Connect the sensors to the sensor connectors. Pin layout of the sensor connector M8 connector (3 pin, socket) No.
50 100 125 2 (Different surfaces, same surface) 1 95 100 70 80 85 75 D-A9 70 + 40 (n 4) 2 (n = 4, 8, 12, 16) 75 + 40 (n 4) 2 (n = 4, 8, 12, 16) 80 + 40 (n 4) 2 (n = 4, 8, 12, 16) 85 + 40 (n 4) 2 (n = 4, 8, 12, 16) 95 + 40 (n 4) 2 (n = 4, 8, 12, 16) 100 + 40 (n 4) 2 (n = 4, 8, 12, 16) n 2 (Different surfaces, same surface) 1 45 55 60 70 75 50 D-A9V 45 + 30 (n 4) 2 (n = 4, 8, 12, 16
(n 4) 2 (n = 4, 8, 12, 16) Note 2) CS2 2 (Different surfaces, same surface) 1 80 85 90 95 100 110 D-M9lA n 80 + 40 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 85 + 40 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 90 + 40 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 95 + 40 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 100 + 40 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 110 + 40 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 2 (Different surfaces