RLQ Symbol Standard Stroke MLU W MLGP Bore size (mm) Standard stroke (mm) 20, 25, 30, 40, 50, 75, 100 30, 40, 50, 75, 100 32, 40 50, 63 ML1C Manufacture of Intermediate Stroke W Retraction locking Without bypass pipe Extension locking Without bypass pipe Method Ordering Description Exclusive body Please refer to How to Order for standard part no. (page 844).
Symbol Specications -XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C)1 CA2 -XB7 Cold resistant cylinder (40 to 70C)2 CS1 -XB9 Low speed cylinder (10 to 50 mm/s) -XB13 Low speed cylinder (5 to 50 mm/s) -XC4 With heavy duty scraper -XC6 Made of stainless steel -XC8 Adjustable stroke cylinder/Adjustable extension type -XC9 Adjustable stroke cylinder/Adjustable retraction
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
4.5 1.5 7 10 0.5 20 13 36 M5 24.5 10.5 50.5 59 22 14 21 11 6 14 (13.5) (7.5) M5 M5 0.005 0.020 0 0.043 50 40 13 22 5 2 8 12 1.0 26 14 43 M5 34.5 14 64 75 24 15.5 25 16.5 8 16 (18) (10) M5 M5 0.005 0.020 0 0.052 63 45 15 30 6.5 4.5 9 20 1.5 31 20 56 M5 39.8 17 79.5 90 30 21 31.6 17.5 10 25 (16) (10) 10 Rotary Actuator Series CRB2 Vane Type Dimensions: 10 Double vane # Following figures show
B 9 18 () 22 10 SOL. A 23 6 () 11 Station 8 SOL.
P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 Series CDRB1BW50 Series CRB1 Series CRB2 Single/Double type CDRB1BW63,80,100 Solid state switch for size 10 and 15 requires no switch block, therefore the unit part no. will be P211070-13.
VQ 0 5 1 1 0 1 10
VQ 0 5 1 1 0 1 10
Electric Actuator with Integrated Guide Series LTF Series LTF Lead screw lead mm Page Series Guide type Motor type Model Mounting orientation Ground ball screw Rolled ball screw 6 10 20 10 20 6 10 20 10 20 LTF6 LTF8 LTF6 LTF8 Page 60 to Horizontal 10 10 Page 68 to Standard Frame-type LTF motor linear guide 6 6 Page 76 to Vertical 10 10 Page 84 to Construction Page 92 Mounting Page 93
6.5 7.0 7.5 8.0 Parallel gripper 6.5 7.0 7.5 8.5 30 to 10 30 to 10 30 to 10 22.5 to 10 Angular gripper 180 opening/closing 88 to 5 54 to 6 58 to 5 41 to 5 30 to 4 Note) The operating range for grippers is measured when both ends are open.
5 10 15 4 6 10 15 10 12 19 27 11.5 13.9 22 31 Variation Action Mounting Note 2) Bore size (mm) Mounting Series Bore size (mm) Standard stroke (mm) 5, 10, 15 (20) Note 1) Series Action Standard stroke (mm) 5, 10, 15 5, 10, 15 5, 10, 15 5, 10, 15 4 6 10 16 4 6 10 15 Basic Flange Foot Clevis Trunnion Panel mount type, Embedded type Single acting, Spring return Double acting, Single rod 5, 10
Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet Flat Type with Groove A 3 30.5 11 1.2 11 04 6 37 14 14.5 10 47 18 20.5 J K Width across flats E 3 30.5 11 1.8 11 6 37 14 14.5 10 47 18 20.5 06 08 N S U F GN GS HS 7 15 55 36.5 1.2 10 20 62.5 44 06 08 15 55 36.5 1.8 20 62.5 44 04 JB K ZP3 T UM B5 C2 3 31.5 12 11 J K 10 6 38 15 14.5 10 48 19 20.5 JB K 15 56 37.5 10 20 63.5 45 10
50 20 20 10 10 10 5 4 3 2 1 40 30 20 0.2 1 2 3 4 5 0.3 0.4 10 m1max m2max m3max m1max m3max m2max Weight (kg) Weight (kg) 10 Model Selection Series MY3A/3B MY350 w When the external guide is used. 300 400 500 Collision deceleration (m/s2) 200 External guide load factor selection 2300 N 100 External shock absorber Impact force and absorption capacity confirmation 30 40 50 20 10 2 3 4 5 10
HRR050-W-20 30 Facility water flow rate [L/min] 25 20 15 10 5 0 0 10 20 30 40 50 Facility water inlet temperature [C] This is the facility water flow rate at the circulating fluid rated flow and the cooling capacity listed on pages 20 and 21. 24 HRR Series Dimensions Air-cooled Refrigeration HRR010-A-20-m (75 10) 440 (Includes protruding parts) Ventilation air inlet Ventilation air outlet
, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 6 7 8 9 10 (Refer to the connector wiring diagram.)
Note 3) For replacement of the 10 wear ring A, contact SMC or your nearest sales representative. Seal kit includes a grease pack (6, 10: 5 and 10 g, 15 to 63: 10 g). Order with the following part number when only the grease pack is needed.
(Red Green Red) D-M5NW D-M5PW D-M5BW Auto switch model Wiring type 3-wire 2-wire Output type PNP NPN Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 5 to 40 mA 80
14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 4 4 4 18 10.4 20.7 D1 10 L2 A D2 8 H 6 10 10 19.5 12.8 22.8 Connection threads 10 (R) 8 (R) 15.2 18 26 21.5 12 26.3 Applicable tubing 10 18.5 29 41 24 29.4 M L1 17 17 12 20.9 46 58 25 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.
22.5 15.5 9.6 17.5 10 2.5 25.5 24.5 13.7 15.4 14.29 7 18 2.7 8 9 18 5 10 19 3.2 10 20 32 12 20 28 16 23 33 59 28 36 62 10-32UNF 12.7 2.3 9.3 15.6 1 16 22 11.11 5 32 23 16 1 8 1 4 10.4 10 18 3 26 25 14.29 KQ2L05-32 10-32UNF 20 22 2.3 11.11 11.4 10 19.5 3 16 1 8 1 4 22.5 26.5 15.1 23.5 27.5 29.5 24.5 28.5 30.5 26.5 29.5 31.5 35.5 31.5 33.5 37.5 24 26 16.5 3.5 14.29 10-32UNF 2.3 18.1 13.6
Note) D: Max. diameter 8.4 27.5 34.1 30.6 12.7 2.2 2.2 8.4 10 3.2 10 30.1 2.2 2.2 3.2 2.7 R 1 8 M5 x 0.8 28.2 31.3 12.7 34.8 9.3 4 9.3 10 10 30.3 30.8 4.5 4.5 2.2 2.2 11 11 R 1 8 33.4 36.9 M5 x 0.8 K 11.6 13.5 11.6 10 10 6 32.9 R 1 8 M