9/16 21/32 21/32 11/32 11/32 9/32 9/32 10-FB3 10-FB2 10-FB4 10-FB1 10-FLB1 (Short) 10-FLB2 10-FLB2 (Short) 10-FLB1 21 Page 5 Distributed by Power Aire, Inc.
Flow direction symbols on body Meter-out type Meter-in type Flow Rate and Effective Area Symbol JIS symbol ASD230FG ASD330FG ASD430FG ASD530FG ASD630FG 4, 6 Model 6 8 10, 12 10 12 8, 10 6 6, 8 Metric size 1/4" 5/16" 3/8" Tube O.D. 1/8" 5/32" 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size l/min (ANR) Flow rate Controlled (Free) flow 295 350 75 175 500 600 700 1200 1300 4.5 5.3 2.7 1.1 7.6 9.1
L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 5 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 2 to 200 L/min 1 to 1 L/min 10 to 1000 L/min 3 to 3 L/min 20 to 2000 L/min Power supply voltage 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% Temperature characteristics 2% F.S. 2% F.S. (15 to 35C) 2% F.S. (15 to 35C) (25C standard)
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system
capacity [W] Facility water temperature 35C Facility water temperature 20C 1500 1500 1000 1000 Facility water temperature 20C Facility water temperature 10C 500 500 Facility water flow rate: 10 L/min Facility water flow rate: 10 L/min 0 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] HECR012-W Circulating fluid: Tap water
14 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 20 12 12 10,11 10, 11, 12 08, 09 1000 10 15 8 500 06, 07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-53 12 Series ASD-FG Construction ASD230FG ASD330FG/430FG ASD530FG/630FG ASD530FG-02 @1 !
-03 ASG521F-03 ASG620F-04 ASG621F-04 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1000 25 15 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 1500 Effective area (mm2) Effective area (mm2) 20 10, 12 10 08 1000 15 500 10 5 500 5 0 0 0 0 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) 2 Stainless Steel Speed Controller Series ASG Construction Elbow type
FLOW CAPACITY . 10-32 port 1/8" NPT port 2.0 CFM (56 LPM) with supply 10 PSI above set-point 2.3 CFM (65 LPM) with supply 10 PSI above set-point Operating characteristics are influenced by flow and outlet restriction Part Number Description S-5200-10S-5200-30S-5200-60S-5200-1000-10 PSI, 10-32 ports 0-30 PSI, 10-32 ports 0-60 PSI, 10-32 ports 0-100 PSI, 10-32 ports XX XX XX XX 0-10 PSI, 1/
(mm) (1) D L Applicable tubing Nylon Urethane KGR04-08 KGR04-06 1.8 2.0 3.3 3 2.5 3 4.7 4 6 8 10 4 8 10 12 10 12 12 16 16 17.5 18 18.5 21 34.5 36.5 39.5 37 37 39.5 42 41 42 44.5 50.5 50.5 10.4 16 5.6 4 KGR04-10 12.8 KGR06-04 KGR06-08 KGR06-10 KGR06-12 KGR08-10 KGR08-12 KGR10-12 KGR10-16 KGR12-16 4 4 12.8 17 6 18.5 Applicable fitting size d 13.1 10.4 15.2 20 4.0 4.6 33 8 15.2 20 18.5 26.1
12 10,11 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-101 11 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F-02 !
EXW1 EXW1 Up to 100 m V.1.0/V.2.0 Available*1 EXW1 EXW1+EX600 *2 V.1.0 NA EXW1 EX600 Up to 10 m V.1.0 NA EX600 EXW1 Up to 10 m V.1.0 NA Available*3 EX600 EXW1+EX600 Up to 10 m V.1.0 NA Available*3 EX600 EX600 Up to 10 m V.1.0 NA Available *1: Available in protocol V.2.0. *2: Up to 100 m between an EXW1 series Base and Remote, and up to 10 m between an EXW1 series Base and an EX600-W series
0.8 Upstream pressure 0.5MPa 20 10 50 0.15 0.3 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) 40 0.6 Effective area mm Effective area mm Effective area mm 0.1 0.2 30 0.4 10 5 20 0.1 0.05 0.2 10 0 0 0 0 0 Number of needle revolutions 5 10 Number of needle revolutions 5 10 10 20 0 Number of needle revolutions 2 Speed Controller for Low Speed Operation Series AS-FM Construction
Ambient temperature (C) Recommended circulating fluids 10 to 45 Tap water, ethylene glycol aqueous solution 15(wt)% -5 to 10 Ethylene glycol aqueous solution 15(wt)% -20 to -5 Ethylene glycol aqueous solution 40(wt)% Circulating fluid temperature(C) Recommended circulating fluids 10 to 35 Tap water, ethylene glycol aqueous solution 15(wt)% 5 to 10 Ethylene glycol aqueous solution 15(wt)%
15 0 5 10 15 20 25 0 5 10 15 20 Vertical L7 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 600 600 600 Z 400 400 400 200 200 200 Mep m 0 0 0 0 5 10 15 0 5 10 15 20 25 0 5 10 15 20 L8 Work load [kg] Work load [kg] Work load [kg] Calculation of Guide Load Factor Mounting orientation 1.
SOL.B SOL.A 10 10 () (+) White Black SOL.A Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to below.
Core wire colors Brown: Not connected Note 1), 24 VDC 10% (Control power supply) Note 2) White: 24 VDC +10%/5% (Solenoid valve power supply) Blue: Not connected Note 1), 0 V (Control power supply) Note 2) Black: 0 V (Solenoid valve power supply) Gray: Not connected Brown: 24 VDC +10%/5% (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) Blue: 24 VDC 10% (Control power
be mounted. 14-10-2 E-P HYREG Series VY1 Standard Specifications 02 03 04 04 06 10 02 03 04 VY1A0 0 1-M5 VY1B0 0 1M 0 5 1 VY110 0 10 0 1 2 VY120 0 10 0 1 2 VY130 0 1VY140 0 1VY150 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 Model VY1D00-M5 10 M5 01 M5 Port M5 01 02 01 02 02 03 20 04 02 03 04 04 06 10 12 14 P Port size Rc 11 2 1 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 1 1 4 A M5 M5
Flow Direction Symbols on Body Meter-out type Meter-in type Symbol Indication symbol Flow Rate and Sonic Conductance Model ASD230FG ASD330FG ASD430FG ASD530FG ASD630FG Metric size 8, 10 6 8 10, 12 10 12 4, 6 6, 8 6 3/16" 1/4" 1/8" 5/32" 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" Inch size 1/4" 5/16" 3/8" 3/8" Flow rate (L/min (ANR)) 75 175 295 350 500 600 700 1200 1300 Controlled flow Free
10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Note) Distance to the gripping point L of single acting type is shortened by spring return.
Internal Grip External Grip MHKL2-12S MHKL2-12C 20 15 Gripping force (N) Gripping force (N) Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 15 Pressure 0.6 MPa MHZ 10 0.5 MPa 0.5 MPa 10 MHF 0.4 MPa 0.4 MPa 5 5 MHL 0.3 MPa 0.3 MPa F F 0 0 MHR 10 20 30 40 50 10 20 30 40 50 10 20 30 40 50 Note) In case of single acting type, the value is for stroke center.