to the right. 5 5 0.2 MPa 0.2 MPa 0 10 20 30 40 50 0 10 20 30 40 50 F1 Gripping point L (mm) Gripping point L (mm) F1 F1 532 MHR3/MDHR3 Series Rotary Actuated Air Gripper 3-Finger Type Construction q !
Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).
No.PS-OMS0006CN-G / / ZSE20(F) ISE20 2 8 10 11 14 14 16 18 [] 20 21 3 22 24 26 26 26 F0 28 F1 OUT1 29 F3 32 F4 33 F6 35 F10 36 F11 41 F80 42 F81 43 F82 45 F90 46 F98 48 F99 49 50 54 54 55 62 62 64 -1No.PS-OMS0006CN-G *1) (ISO/IEC)(JIS) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules
Model Cushion Bore size (mm) 6 10 16 Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Rubber Air 10-/21-CDU6 10-/21-CDU10 10-/21-CDU16 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 10-/21-CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 10-/21-CDU25 25 Non-lube Double acting Single rod M5 x 0.8 11-/22-CDU6 11-/22-CDU10 11-/22-CDU16 6 10 16 5, 10, 15, 20, 25, 30
Max. load current or load current range (mA) D-A53 None PLC 5 to 50 24VDC 5 to 50 24VDC 5 to 25 100VAC Relay, PLC D-A54 5 to 12.5 200VAC None D-A56 20 IC circuit 4 to 8VDC 50 24VAC/DC or less None D-A64 25 100VAC Relay, PLC 12.5 200VAC None 30 Max. 24VDC None IC circuit, PLC D-A67 (2 color indication) 5 to 40 Relay, PLC 24VDC D-A59W None PLC 5 to 50 D-A33 24VDC 5 to 50 24VDC D-A34
44 51 Approx. 90 10 9.5 Bleed Bleed 63 Exhaust SUP(1) OUT(2) G 2 OUT 30 OUT(2) SUP(1) OUT 10 43 35 EXH Approx. 43 2-Rc(PT) 1/8 Port size 2-Rc(PT) 1/4 Port size Rc(PT) 1/8 Pressure gauge port 50 50 35 2-Rc(PT) 1/8 Pressure gauge port Approx. 60 50 Mounting hole IR300-0 IR2120-02 36 2 Bracket (optional) 30 82 Mounting hole Pressure gauge (optional) 60 2.3 48 Bracket (optional) 5.5 9.5 M5
/60/Hz) DC VO301-00T-X302 Conduit terminal 100 V, 200 V, Other voltage (Option) 24 V, Other voltage (Option) 15 to 10% of the rated voltage Class B or equivalent (130C) 70C or less (When rated voltage is applied.) 12 VA (50 Hz), 10.5 AV (60 Hz) 7.5 VA (50 Hz), 6 VA (60 Hz) 4.8 W Non-locking push type LVA Allowable voltage fluctuation Coil insulation type Temperature rise LVH LVD Inrush Holding
-2No.PS-OMV0003CN-G / *3) 1 1.5 *3)1 1 [] -3No.PS-OMV0003CN-G () () () () -4No.PS-OMV0003CN-G () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMV0003CN-G * FG (35 N () ,() *() 6 33 () 20 m DC(-)() * ( ) -6No.PS-OMV0003CN-G () CE 0~50(5 ) (FKMHNBR) * 1015 10 1% 1959 LCD * -7No.PS-OMV0003CN-G ISE70 02 L2 M 3 Y K T ISE70 0~1MPa ISE71 0~1.6MPa 02 Rc1/4 N02
A quick recovery time indicates little liquid pool. 50 Ratio of resistance [k m] Particle ratio [number/cc] PFMC 100 2 or 3 particles/cc PFMV 10 00 10 20 30 40 50 60 70 PF2A 1 0 5 10 15 20 25 30 Duration of flow [min] Duration of flow [hour] PF3W The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room
(Convertible) Standard 0.2 to 1.0 Operating pressure range (MPa) For vacuum 100 kPa to 0.2 Pilot pressure (MPa) 0.2 to 1.0 (Equivalent to the operating pressure or more) Ambient and fluid temperature (C) 10 to 50 (No freezing) Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance (m/s2) Note) 300/50 Note) Impact resistance: No malfunction to axis and right
L/min 10 L ON OFF ON () OFF () 2 5 5 10 L/min 10550L 14 No.LFE*-OMY0008 sa ON-OFF () 1 L/min 10 11 12 1 L/min () 0 ta (SI )SI LFE ON-OFF () [S/cm](/ 100200S/cm na ON 0 ha 15 No.LFE*-OMY0008 2MPa(69 ) IN ()IN (68 ) DC(-)/ + 2 2 2 20mm 0mm 0mm 0mm 2 2 2 20mm 0mm 0mm 0mm 5 5 5 50mm 0mm 0mm 0mm 5 5 5 50mm 0mm 0mm 0mm 16 No.LFE*-OMY0008 FR0( FR0( FR0( FR0( ) ) ) ) FR1 FR1
Return 0.5 0.4 0.2 0 0 Out -0.2 -0.4 -0.5 -0.6 -0.8 0 25 50 75 -1 1 2 3 4 -1 100 5 Input signal % F.S.
Link, No Activity (10 Mbps) 7 LINK/ACT1 LINK/ACT2 Orange LED flashes. Link, Activity (10 Mbps) Red LED is ON. IP address has been duplicated. 100 Mbps: Green 10 Mbps: Orange OFF EtherNet/IP is not connected. 15 Wireless System EX600-W Series LED Display Wireless slave unit No. LED name Function Color of LED Operation Green LED is ON.
-8-A-X2112 1 C42FP-260S 1 111692 1 1 2019 3 2019 2 SERIAL No.XP AD48-8-X2110 SMC WEB IDF Series 9-2 9 2 IDX-OM-W026 10 L 10 L 10-1 ( ) 10-2 1.6MPaADH4000-04 IDF22E-**-L IDF37E-**-L IDF55E-**-L IDF75E-**-L 0.151.6 ) N.O. () ) 50L/min(ANR) (ADH4000-04) ( 10) IDF Series 10-1 10 1 IDX-OM-W026 10 L 10-3 IDF Series 10-3 10 2 IDX-OM-W026 11 M 11 M 11-1 ( ) IDF Series
-03 9.6 10 17.5 33 21.5 15.5 2.5 4 6 KQL04-06 10.4 10 18 33 21.5 16 4.2/4.2 4 8 KQL04-08 10.4 10 18 35 22 16 4.2/4.2 1/8 4.8(3/16) KQL01-05 9.6 10 17.5 33 21.5 15.5 2.5 6 8 KQL06-08 12.8 10 20 36.5 24.5 17 11.4/11.4 5/32 4.8(3/16) KQL03-05 10.4 10 18 33.5 22.5 16 3 6 10 KQL06-10 12.8 10 20 38.5 24 17 11.4/11.4 5/32 6.3(1/4) KQL03-07 10.4 10 18 34 22.5 16 3 8 10 KQL08-10 15.2 12 23 39.5 26
uctuation 15% to +10% of rated voltage Min. applicable load 5 VDC, 1 mA (Load resistance) 5 VDC, 5 mA (Load resistance) Max. voltage 24 VDC Power consumption 2.2 W Suppressor Diode Max. load current 50 mA Indicator LED Max. load inductance 0.5 H Insulation voltage 300 V 600 V Protection against electric shock Class II (EN60947-5-1: 2004) 20 VG342-X87 Symbols Safety limit switch Made by OMRON
Bore size(mfn) Standard stroke(mm) MGOftl Slide bearing MGor12, rc 10, 20, 30, 40, 50 MGOr2o,2s 20, 30, 40, 50, 75, 100 25, 50, 75, 100 MGOL Ball bush bearing MGOr32,40, 50, 63, 80,1OO . intermediate stroke As to intermediate stroke (5, 10, 15, 20, 30, 35 )' spacer of 5, 10' 15,20mm width will be used (Example) MGOM50-10 is produced by installing 1smm spacel in MGQM50'25 Consult factory when
0.5 s 1 s 1.5 s 2 s 2.5 s 50 50 100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 3) Supply pressure: 0.2 MPa Flow rate consumption: 188 L/min (ANR) 4) Supply pressure: 0.3 MPa Flow rate consumption: 253 L/min (ANR) 200 200 150 150 2.5 s 2 s 100 100 50 50 0.5 s 1 s 1.5 s 2 s 0.5 s 1 s 1.5 s 50 50
workpiece (mm) 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) Size: 80 Size: 100 30 50 0.4 (MPa) 0.4 (MPa) 25 40 0.3 (MPa) 0.3 (MPa) Lifting force (N) Lifting force (N) 20 30 0.2 (MPa) 15 0.2 (MPa) 20 10 0.1 (MPa) 0.1 (MPa) 10 5 0 0 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) 738 Non-contact Gripper XT661 Series