refrigerationR134a (HFC)PID controlTemperature: 10 to 35 C, Humidity: 30 to 70%RHClear water, Deionized water10 to 408.0 (at 20 C)1.25 (at 20 C)?
refrigerationR134a (HFC)PID controlTemperature: 10 to 35 C, Humidity: 30 to 70%RHClear water, Deionized water10 to 408.0 (at 20 C)1.25 (at 20 C)?
VQC1100 10ms2ms: 200 million cycles VQC2100 20ms2ms: 200 million cycles VQC4100 17ms3ms: 100 million cycles SV VQC Refer to catalog for details.
VQC1100 10ms2ms: 200 million cycles VQC2100 20ms2ms: 200 million cycles VQC4100 17ms3ms: 100 million cycles SV VQC Refer to catalog for details.
MGP(kg) MGPM12100 (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 MGPM12 0.24 0.28 0.31 0.35 0.39 0.50 0.59 0.70 0.79 0.89 0.98 1.17 16 MGPM16 0.33 0.38 0.43 0.48 0.53 0.68 0.80 0.97 1.09 1.22 1.35 1.60 20 MGPM20 0.67 0.75 0.83 0.91 1.17 1.37 1.57 1.76 1.96 2.16 2.63 3.03 3.42 3.82 25 MGPM25 0.95 1.05 1.16 1.27 1.65 1.92 2.19 2.47 2.74 3.01 3.67 4.21 4.76 5.30 32 MGPM32
HOW Replacement Element Part No. 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) Element size Port size (Nominal size) 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) 28 (3 1/2B), 32 (4B) 65 x 90 85 x 110 100 x 160 120 x 180 140 x 200 180 x 260 EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N EM001H-105N EM101H-105N EM201H-105N EM301H
8-J NA (mm) Stroke range Bore size (mm) A AL B1 C D DL2 E F GA GB H H1 HR HN (max.)
Types: Dryers, Method: Desiccant type heatless, Shape: Standard, Outlet Flow Rate(l/min): 155, Outlet Open Air Pressure Dew-Point(°C): -50, Exit Flow Rate Class(l/min): Up to 200, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 5 to 50, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 1/2, Control Side Connection Type: [Rc (R)] Rc, Control Side Plumbing
, 2C, LE ACTUATOR, ModelCompatible motor capacity [W]Compatible encoderMain power supplyControl power supplyParallel inputParallel outputMax. input pulse frequency [pps]FunctionOperating temperature range [ C]Operating humidity range [%RH]Storage temperature range [ C]Storage humidity range [%RH]Insulation resistance [M ]Weight [g]Power voltage [V]Allowable voltage range [V]Rated voltage
Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 100~120V no longer available; 200~230 (LECSS-S); 200~240 (LECSS-T); Display and settings buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSS2-T only)
Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 100~120V no longer available; 200~230 (LECSS-S); 200~240 (LECSS-T); Display and settings buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSS2-T only)
Bore size/Stroke (mm) 10 25, 50, 75, 100 Cushion (Option) 15 25, 50, 75, 100, 125, 150, 175, 200 With adjusting bolt (2 pcs.) Nil 25 25, 50, 75, 100, 125, 150, 175, 200 B With shock absorber (2 pcs.) For 15 and 25, strokes up to 300 are available as made-to-order. (-XB11) BS With shock absorber (1 pc.)
range Symbol Specifications 025 25 mm 050 50 mm 100 100 mm 200 200 mm Lead wire Symbol Specifications A Separate line, 2.0 m B M8-4 pin, 0.3 m C M12-4 pin, 0.3 m 4
V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) Class B G C D, T S S L, Z Note) Be sure to read this before handling the products.
AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 AMF150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.
AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Rated flow (l/min (ANR))(1) 200 500 1000 2000 3500 6000 12000 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 1, 11/2 11/2, 2 3/4, 1 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow capacity at a pressure of 0.7MPa.
TYPICAL INSTALLATION S ngle Actnq Aciuoio' Splined Shaft Fitting Assembly (long) (c) 210050-31 Connecting feedback shaft to main spindle of actuator.
Cooling capacities: 2 kW, 8 kW, 15 kW, 30 kW ; Temperature range setting: 20 to 90°C ; Temperature stability: ±0.3°C ; Power supply requirement: 3-phase 200 VAC / 50Hz or 3-phase 200~208 VAC / 60Hz ; Circulating fluid: Clear or deionized water, fluorinated liquid, or 60% ethylene glycol solution ; Standards: UL, CE, SEMI (S2-0703, S8-1103, F47-0200), SEMATECH (S2-93, S8-95)
Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: Fluorinert™ or GALDEN® (see catalog for compatibility); Temperature range setting: -10 to 90°C (2kW), -20 to 90°C (4, 8, 10kW); Note: Temperature range depends on fluorinated fluid choice; Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8