SMC Corporation of America
Elite Part Number Search
Search Results "CDM2C20-75Z-A93"

Magnet: Built-in, Type: Pneumatic, Mounting: Single Clevis, Bore: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Leadwire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Single Clevis, Bore: 20mm, Port Thread: Rc, Stroke: 25mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Leadwire or Prewired Connector: -, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Single Clevis, Bore: 20mm, Port Thread: Rc, Stroke: 25mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Leadwire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Single Clevis, Bore: 20mm, Port Thread: Rc, Stroke: 25mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Leadwire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Single Clevis, Bore: 20mm, Port Thread: Rc, Stroke: 25mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: H7BA--Solid State, Water Resist., 2 Wire, Leadwire or Prewired Connector: 3m, Number: -

Magnet: D (Built-in Magnet), Mounting: C (Single Clevis), Bore Size: 20mm, Port Thread: Rc, Stroke: 250mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Pivot Bracket: No Bracket, Rod End Bracket: W (Double Knuckle Joint)

Magnet: D (Built-in Magnet), Mounting: C (Single Clevis), Bore: 20mm, Port Thread: Rc, Stroke: 100mm, Cushion: A (Air Cushion), Rod End Thread: Male Rod End, Rod Boot: J (Nylon Tarpaulin), Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental

(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

Note 4) Figures in ( ) in the table W are D-A93.

-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.

Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with p are produced upon receipt of order.

D-M9/M/9W/M9A Less than 20 stroke Note 2) Less than 55 stroke Note 2) D-A90/A93 Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in types other than those mentioned in Note 1. 152 Auto Switch Mounting CJ2Y Series Operating Range Auto Switch Mounting Brackets/Part No.

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

D-M9/M9W/M9A D-A90/A93 Less than 20 stroke Note 2) Less than 55 stroke Note 2) Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in styles other than those in Note 1.

D-A90(V) AC DC AC DC 100V or less 20mA AC DC 24V or less 50mA Maximum load current Contact protection box OUT () Brown [Red] Reed switch Reed switch Reed switch Contact protection circuit Internal voltage drop CD-P11 OUT ( ) Blue [Black] CD-P12 D-A93, A93V, D-A96, A96V (with indicator light) D-A93(V) D-A93 In-line D-A93V Perpendicular D-A96 In-line D-A96V Perpendicular Relay, PLC IC circuit