SMC Corporation of America
Elite Part Number Search
Search Results "CY1L32H-800B-J79W"

Magnet: Built-in, Mounting: Front Flange, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: C+M, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: -, Rod End Bracket: -, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Mounting Threads

(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options: Rod End Male Thread, Auto Switches: J79W

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m)

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m)

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: J79W, Lead Wire Length(m)