Cable type Terminating resistor Communication cable for CC-Link 110 1/2 W Built-in terminating resistor 110 Set the SI unit DIP Switch-No.2 to ON With socket for BUS IN PCA-1567720 With plug for BUS OUT PCA-1567717 CC-Link Ver.1.00 dedicated High-performance cable 130 1/2 W N/A Note Use the internal terminating resistor only when the SI unit is placed at the end of the CC-Link main line
Cable type Terminating resistor CC-Link dedicated cable 110 1/2 W (Brown, Brown, Brown) CC-Link dedicated cable compatible to Ver.1.10 CC-Link dedicated high performance cable 130 1/2 W (Brown, Orange, Brown) Fig. 3 Use the correct terminating resistor, available from the manufacturer of the CC-Link master. Use a CC-Link-dedicated cable, or a cable with the same specifications.
Cable type Terminal resistor CC-Link dedicated cable 110 1/2 W (brown, brown, brown) CC-Link dedicated cable compatible with Ver.1.10 CC-Link dedicated high performance cable 130 1/2 W (brown, orange, brown) Refer to Fig. 4 about how to connect to the unit. Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm. NOTE 1.
Cable specification Impedance 135 to 165 Capacitance between conductors 30 pF/m or less Conductor resistance 110 /km or less Cable diameter 0.64 mm or more Conductor area 0.34 mm2 or more -32No.EX-OMI0032-G Dimensions GW unit (EX510-GPR1) -33No.EX-OMI0032-G SI unit Summary of Product Parts SI unit is the unit to be combined with manifold solenoid valves to communicate with GW unit.
Blank flange Tested product orientation : Sideways Vacuum pump 110 Pa Endurance test condition
Rotation angle Caution A B 6 10 16 A 54 62 55 B 110 110 102 12 Snap ring installation/removal Caution To replace seals or grease the cylinder during maintenance, use an appropriate pair of pliers (tool for installing a type C snap ring for hole). After re-installing the cylinder, make sure that the snap ring is placed securely in the groove before supplying air.
ISE80 ISE80H ZSE80 ZSE80F (positive pressure) (positive pressure) (vacuum) (compound) Rated pressure range -0.1 to 1 MPa -0.1 to 2 MPa 0 to 101 kPa -100 to 100 kPa Set pressure range -0.105 to 1.1 MPa -0.105 to 2.2 MPa 10 to 111 kPa -110 to 110 kPa Withstand pressure 2 MPa 4 MPa 500 kPa 0.001 MPa (1.999 MPa) Setting and display resolution 0.001 MPa 0.1 kPa 0.01 MPa (2.00 to 2.20 MPa) Port
A B C D E F G H LAT3-10 10 49 4 60 50 4 10.5 LAT3-20 20 69 6 25 90 80 14 20.5 LAT3-30 30 89 6 25 120 110 24 30.5 13 - LAT3-50 Note 1) Refer to Mounting screw specifications and tightening torques in section 4.3 Mounting (P.24). Note 2) The length of the part of the dowel pin inserted into the positioning hole should be shorter than the specified depth.
MPa) of bracket Rod side 0.3 103 92 113 108 124 155 162 Head L Foot: side Frang flange e F 0.5 79 70 86 81 94 118 122 L G F 0.7 66 58 72 67 78 98 101 0.3 45 38 47 46 54 67 69 0.5 33 27 34 33 39 49 49 G 0.7 26 22 27 26 31 39 39 0.3 96 83 106 102 118 147 152 Center C Clevis trunnion 0.5 71 61 76 75 88 109 113 CD T D 0.7 59 50 62 61 72 89 92 0.3 135 119 147 146 167 208 217 0.5 101 89 111 110
Vacuum pump Durability test conditions 110 Pa
-6 Leakage Pam3/s Internal 1.310-9 Note4) External 1.310-11 Piping method Face seal fitting and compression fitting / (Rc, NPT) Threaded ports Port size Inch Face seal fitting Compression fitting 1/4 3/8 1/4 3/8 Rc, NPT 1/8 1/4 3/8 Rated voltage Note 5) 100/110/200/220/230/240/24/48VAC 12/24VDC Ambient and fluid temperature oC 5to60 Power consumption [W] Note 6) DC polar indication 4.5 7
And rotate it clockwise manually until feeling snap fit (approx. 110) to fix to the element. Mount the bolw assembly. Hold the bowl assembly by hand and rotate clockwise. Do not use tool for mounting because the bowl may be damaged. See check item for referential tightening torque.
Test product orientation: Horizontal : 110 Pa Vacuum pump 1 to 10 Pa Endurance test conditions
15 25 60 20 3 3.5 M5 x 0.8 10 5 16 49 24 57 42 51 37 20 22 42 110 15 16 26 60 24 3 3.5 M5 x 0.8 10 5 20 60 28.5 71 49 66 44 24 44 120 30 40 78 28 3 3.5 M6 x 1 12 18 25 73 34 86 60 78 50 24 44 12 29 39 77 34 4 4.5 M6 x 1 12 17 [mm] MGPKL: A, DB, and E Dimensions Bore size [mm] A DB E 30 st or less Over 30 st 100 st or less Over 100 st 30 st or less Over 30 st 100 st or less Over 100 st 16
C D depth E F F (B) MHZ D MHF MHL (E) MHR F-F MHK MHS MHC MHT (mm) MHY D E 0.5 A Model MHSL3-16D MHSL3-20D MHSL3-25D MHSL3-32D MHSL3-40D MHSL3-50D MHSL3-63D MHSL3-80D MHSL3-100D MHSL3-125D B C 12.5 16 18.5 25 27 35 44 54 70 80 5.5 18 21.5 24 34 37 44 56 70 90 110 MHW 0.6 M2 x 0.4 5.4 -X 5.2 0.8 1 8 M3 x 0.5 MRHQ MA 9.5 1.5 M4 x 0.7 D595 Parallel Style Air Gripper/4-Finger Type Series MHS4
(Newark) 3434 US Hwy.22 West, Ste. 110 Somerville, NJ 08876 Tel: (908) 253-3241 FAX: (908) 253-3452 SMC Pneumatics lnc. (Detroit) 2990 Technology Drive Rochester Hills, Ml 48309 Tel: (248) 299-O2O2 FAX: (2a8) 293-3 SMC Pneumatics Inc. (St. Louis) 4130 Rider Trail North Earth City, MO 63045 Tel: (314) 209-0080 FAX: (314) 209-0085 SMC Pneumatics lnc. (Charlotte) 5029-8 West W.T.
With auto switch Basic/CS1BQ (mm) Bore (mm) 125 140 160 Stroke range (mm) S A H AL ZZ lB lC D E F G J K KA M MM N P 1/ 2 to 1000 98 50 110 47 235 145 115 36 90 43 16 M14 X 1.5 15 31 27 M30 X 1.5 35 1/ 2 to 1000 98 50 110 47 235 161 128 36 90 43 16 M14 X 1.5 15 31 27 M30 X 1.5 35 3/ 4 256.5 to 1200 106 56 120 53 182 144 40 90 43 18.5 M16 X 1.5 17 36 30.5 M36 X 1.5 39 CS1BQ125SCS1125, #1 CS1BQ140SCS1140
Series AKH/AKB Check Valve with One-touch Fitting. 92 92 92 93 94 95 95 95 95 97 99 100 100 100 101 102 103 103 104 105 106 107 107 107 108 109 110 110 111 112 113 114 114 114 115 115 116 116 116 116 117 117 118 118 118 119 119 120 120 122 123 124 124 124 124 125 125 126 Features. Series AKH/AKB Check Valve with One-touch Fitting. How to Order. Specifications. Dimensions . Construction.
(Newark) 3434 US Hwy. 22 West, Ste. 110 Somerville, NJ 08876 Tel: (908) 253-3241 FAX: (908) 253-3452 SMC Pneumatics Inc. (Charlotte) 5029-B West W.T. Harris Blvd. Charlotte, NC 28269 Tel: (704) 597-9292 FAX: (704) 596-9561 SMC Pneumatics Inc. (St. Louis) 4130 Rider Trail North Earth City, MO 63045 Tel: (314) 209-0080 FAX: (314) 209-0085 SMC Pneumatics Inc.
(New Jersey) 3434 US Highway 22 West Suite 110 Somerville, NJ 08876 Tel: (908) 253 3241 Fax: (908) 253 3452 SMC Pneumatics Inc. (Columbus) 3687 Corporate Drive Columbus, OH 43231 Tel: (614) 895 9765 Fax: (614) 895 9780 EUROPE CHILE SMC Pneumatics (Chile) Ltda. TAIWAN SMC Pneumatics (Taiwan) Co Ltd.